28.09.2015 Views

Research Journal of Science & IT Management - RJSITM - The ...

Research Journal of Science & IT Management - RJSITM - The ...

Research Journal of Science & IT Management - RJSITM - The ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

e due to: Oral contraceptives, Obstructive pancreatitis, Hepatitis/Mononucleosis/CMV, Congestive<br />

heart failure, Parasites etc.<br />

MATERIAL AND METHODS<br />

<strong>The</strong> experimental study consisted <strong>of</strong> 100 pregnant women, which were divided into groups as follows:<br />

According to fetus age:<br />

- 3 women in first trimester<br />

- 19 women in second trimester<br />

- 78 women in third trimester<br />

According to maternal age:<br />

- 5 women < 20 years old<br />

- 67 women 20-30 years old<br />

- 28 women >30 years old<br />

According to zinc measurements:<br />

- 64 cases were anemic<br />

- 36 cases were normal<br />

According to alkaline phosphatase (ALP) determination:<br />

- 20 cases with low ALP levels<br />

- 65 cases with normal ALP levels<br />

- 15 cases with high ALP levels<br />

According to maternal diagnosis:<br />

- 34 cases were cephalic<br />

- 14 cases with anomalies<br />

- 5 cases with anemia<br />

- 13 cases with preeclampsia<br />

- 12 cases premature delivery<br />

- 2 cases hyperemesis<br />

- 2 cases with diabetes<br />

- 2 cases abortion<br />

- 2 cases illegal<br />

- 3 cases membrane ruptures<br />

- 3 manual rupture<br />

- 3 cases breech delivery<br />

- 1 case with fetal hypotrophy<br />

- 1 case placenta previa<br />

- 2 cases twin pregnancy<br />

- 1 case baby death<br />

<strong>The</strong> techniques used for the determination <strong>of</strong> serum zinc, included Colorimetry, Polarography, X-ray<br />

fluorescence, Fluorometry and Atomic Absorption Spectroscopy (AAS). AAS techniques are preferred<br />

in the clinical laboratory, because <strong>of</strong> their specificity, sensitivity, precision, simplicity, and relatively<br />

low cost per analysis. (4)<br />

<strong>The</strong> direct dilution method presented here requires less than 2 min per sample. We used Glycerol as a<br />

solvent for the standards, and it also serves as an ideal additive for adjusting the viscosity and flow rate<br />

<strong>of</strong> the standards. We took 2 ml blood from each pregnant woman and serum zinc level was measured<br />

directly by using Atomic Absorption Spectrometry (VARIAN AAS-220), at the same time we<br />

www.theinternationaljournal.org > RJS<strong>IT</strong>M: Volume: 02, Number: 02, December-2012 Page 26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!