3. Press the [Done] soft key to save the parameter.<br />
Note: The default password is set to the serial number of the TigerStop.<br />
TA On Time Out<br />
TA on time out is the time the tool is given to get to the TA sensor after<br />
the tool leaves the DM sensor.<br />
To change TA On Time Out...<br />
1. Enter the password and press [=].<br />
2. Enter the new TA On Time Out value.<br />
3. Press the [Done] soft key to save the parameter.<br />
Note: Slow cycling tools will need a higher TA On Time Out.<br />
Note: The default password is set to the serial number of the TigerStop.<br />
TA Off Time Out<br />
TA off time out is the time the tool is given to get off of the TA sensor after<br />
TigerStop has turned off the output to cycle the tool.<br />
To change TA Off Time Out...<br />
1. Enter the password and press [=].<br />
2. Enter the new TA Off Time Out value.<br />
3. Press the [Done] soft key to save the parameter.<br />
Note: Slow cycling tools will need a higher TA Off Time Out.<br />
Note: The default password is set to the serial number of the TigerStop.<br />
DM On Time Out<br />
DM on time out is the time the tool is given to get back to the DM sensor<br />
after the TA sensor turns off.<br />
To change DM On Time Out...<br />
1. Enter the password and press [=].<br />
2. Enter the new DM On Time Out value.<br />
3. Press the [Done] soft key to save the parameter.<br />
Note: Slow cycling tools will need a higher DM On Time Out.<br />
Note: The default password is set to the serial number of the TigerStop.<br />
Clamp Off Delay<br />
Clamp off delay is the time that TigerStop waits after the DM comes back<br />
on to turn off the clamps.<br />
To change Clamp Off Delay...<br />
1. Enter the password and press [=].<br />
36