Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)<br />

<strong>2010</strong> <strong>CBC</strong> Chapter 11B <strong>2013</strong> <strong>CBC</strong> Chapter 11B Comments<br />

1115B.1 General. • 11B-213.2 Toilet Rooms and<br />

Bathing Rooms<br />

• 11B-603.2 Clearances<br />

General scoping and clearance<br />

requirements for <strong>to</strong>ilet and bathing<br />

facilities<br />

Exception: In existing<br />

buildings and facilities . . .<br />

1115B.1.1 Separate and unisex<br />

facilities.<br />

1115B.1.2 Where used by<br />

children.<br />

1115B.2 Bathing and shower<br />

facilities.<br />

• 11B-202.3 Alterations.<br />

Exception 2. Technically<br />

Infeasible.<br />

• 11B-202.4 Path of Travel<br />

Requirements in Alterations,<br />

Additions and Structural<br />

Repairs. Exception 8.<br />

11B-213.2 Toilet Rooms and<br />

Bathing Rooms<br />

11B-604.9 Water Closets and<br />

Toilet Compartments for<br />

Children’s Use<br />

11B-213.3.6 Bathing<br />

Facilities<br />

The Unreasonable Hardship exceptions for<br />

specific situations are replaced by<br />

provisions for technical infeasibility and an<br />

unreasonable hardship for path of travel<br />

improvements. These exceptions must be<br />

developed by the applicant on a case-bycase<br />

basis for submission <strong>to</strong> the enforcing<br />

authority for its consideration and, if<br />

approved, documentation <strong>to</strong> its file.<br />

General scoping for <strong>to</strong>ilet and bathing<br />

facilities<br />

General scoping for <strong>to</strong>ilet and bathing<br />

facilities used by children<br />

General scoping for bathing facilities<br />

1115B.3 Toilet facilities. 11B-604.1 General Technical requirements for <strong>to</strong>ilet facilities<br />

1115B.3.1 Multipleaccommodation<br />

<strong>to</strong>ilet facilities.<br />

11B-213.2 Toilet Rooms and<br />

Bathing Rooms<br />

Scoping for multiple-accommodation <strong>to</strong>ilet<br />

facilities<br />

1. Wheelchair clearance. 11B-603.2 Clearances Technical requirements for turning space<br />

2. Clear floor space at<br />

fixtures.<br />

11B-603.2 Clearances<br />

Technical requirements for overlap and<br />

door swing<br />

3. Accessible fixtures. • 11B-213.3.2 Water Closets<br />

• 11B-213.3.4 Lava<strong>to</strong>ries<br />

Scoping for water closets and lava<strong>to</strong>ries<br />

4. Accessible water closet<br />

compartment.<br />

4.1. The compartment<br />

shall be . . . 60 inches<br />

wide.<br />

11B-604.8.1 Toilet<br />

Compartments<br />

11B-604.8.1.1 Size<br />

Technical requirements for accessible<br />

compartment within multipleaccommodation<br />

<strong>to</strong>ilet facilities<br />

Technical requirement for width of<br />

compartment<br />

Amendment includes the requirements for<br />

maneuvering clearance in wheelchair<br />

accessible compartments.<br />

Cross Reference Guide - <strong>2010</strong> <strong>CBC</strong> <strong>to</strong> <strong>2013</strong> <strong>CBC</strong> Page 40 of 114<br />

Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) July 1, 2015