<strong>2010</strong> <strong>CBC</strong> Chapter 11B <strong>2013</strong> <strong>CBC</strong> Chapter 11B Comments<br />

Exception 3 11B-405.8, Exception 4 Exception for handrails at door landings at<br />

ramps less than 6” in rise or 72” in length<br />

1133B.5.5.1.1 Ramp handrails.<br />

1133B.5.6 Guide curbs and<br />

wheel guide rails.<br />

11B-505.10 Handrail<br />

Extensions<br />

Exception 3<br />

• 11B-405.9 Edge Protection<br />

• 11B-405.9.2 Curb or Barrier<br />

Model code amended <strong>to</strong> add handrail<br />

extension at hazard turned 90 degrees.<br />

Technical requirements for ramps – edge<br />

protection<br />

1133B.5.6.1 11B-405.9.2 Curb or Barrier Technical requirements for ramps – edge<br />

protection<br />

1133B.5.6.2 11B-405.9.2 Curb or Barrier Technical requirements for ramps – edge<br />

protection<br />

1133B.5.7 Guards. Chapter 10, Section 1013.2<br />

Where required<br />

Technical requirements for guards at<br />

ramps located more than 30 inches above<br />

the floor.<br />

1133B.5.8 Outdoor ramps. 11B-405.10 Wet Conditions Technical requirements for ramps – wet<br />

conditions<br />

1133B.6 Aisles. 11B-403 Walking Surfaces General technical requirements for aisles<br />

1133B.6.1 General. Chapter 10, Section 1017 General technical requirements for aisles<br />

1133B.6.2 Width.<br />

• 11B-403.5.1 Clear Width<br />

• 11B-403.5.1, Exception<br />

Technical requirements for aisle width<br />

1133B.7 Walks and sidewalks. • 11B-403 Walking Surfaces<br />

• 11B-302.1 General<br />

General technical requirements for walks<br />

and sidewalks<br />

1133B.7.1 Continuous surface.<br />

Exception<br />

1133B.7.1.1 Slopes less than 6<br />

percent.<br />

• 11B-403.1 General<br />

• 11B-403.2 Floor or Ground<br />

Surface<br />

• 11B-403.5.1, Exception 3<br />

• 11B-403.5.3 Passing Spaces<br />

• 11B-302.1 General<br />

• 11B-202.3 Alterations.<br />

Exception 2. Technically<br />

Infeasible.<br />

• 11B-202.4 Path of Travel<br />

Requirements in Alterations,<br />

Additions and Structural<br />

Repairs. Exception 8.<br />

11B-403.2 Floor or Ground<br />

Surface<br />

General technical requirements for walks<br />

and sidewalks – continuous surface, no<br />

abrupt level changes, 48” width, and<br />

passing spaces<br />

The Unreasonable Hardship exceptions for<br />

specific situations are replaced by<br />

provisions for technical infeasibility and an<br />

unreasonable hardship for path of travel<br />

improvements. These exceptions must be<br />

developed by the applicant on a case-bycase<br />

basis for submission <strong>to</strong> the enforcing<br />

authority for its consideration and, if<br />

approved, documentation <strong>to</strong> its file.<br />

Technical requirements for walks and<br />

sidewalks – slip resistant surface<br />

Cross Reference Guide - <strong>2010</strong> <strong>CBC</strong> <strong>to</strong> <strong>2013</strong> <strong>CBC</strong> Page 92 of 114<br />

Section 1133B General Accessibility for Entrances, Exits and Paths of Travel July 1, 2015