CROSS REFERENCE GUIDE ACCESSIBILITY PROVISIONS 2010 CBC to 2013 CBC
2010CBC-2013CBC_CrossReferenceMatrix
2010CBC-2013CBC_CrossReferenceMatrix
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>2010</strong> <strong>CBC</strong> Chapter 11B <strong>2013</strong> <strong>CBC</strong> Chapter 11B Comments<br />
Exception 2<br />
• 11B-202.3 Alterations.<br />
Exception 2. Technically<br />
Infeasible.<br />
• 11B-202.4 Path of Travel<br />
Requirements in Alterations,<br />
Additions and Structural<br />
Repairs. Exception 8.<br />
The Unreasonable Hardship exceptions for<br />
specific situations are replaced by<br />
provisions for technical infeasibility and an<br />
unreasonable hardship for path of travel<br />
improvements. These exceptions must be<br />
developed by the applicant on a case-bycase<br />
basis for submission <strong>to</strong> the enforcing<br />
authority for its consideration and, if<br />
approved, documentation <strong>to</strong> its file.<br />
Exception 3 11B-308.3.1, Exception 2 Exception for operable parts of fuel<br />
dispensers<br />
1117B.7.1.1<br />
1117B.7.1.1.1 One ATM.<br />
1117B.7.1.1.2 Two ATMs<br />
1117B.7.1.1.3 Three or more<br />
ATMs<br />
1117B.7.1.2 Where bins …<br />
1117B.7.1.3 (point-of-sale)<br />
1117B.7.2 Clear floor or ground<br />
space.<br />
11B-220.1 Au<strong>to</strong>matic Teller<br />
Machines and Fare Machines<br />
11B-220.1.1 One Au<strong>to</strong>matic<br />
Teller Machine or Fare<br />
Machine<br />
11B-220.1.2 Two Au<strong>to</strong>matic<br />
Teller Machines or Fare<br />
Machines<br />
11B-220.1.3 Three or More<br />
Au<strong>to</strong>matic Teller Machines or<br />
Fare Machines<br />
11B-220.1 Au<strong>to</strong>matic Teller<br />
Machines and Fare Machines<br />
11B-220.2 Point-of-Sale<br />
Devices<br />
11B-707.2 Clear Floor or<br />
Ground Space<br />
Scoping for au<strong>to</strong>matic teller machines<br />
Scoping for au<strong>to</strong>matic teller machines<br />
Scoping for au<strong>to</strong>matic teller machines<br />
Scoping for au<strong>to</strong>matic teller machines<br />
Scoping for bins for envelopes, waste or<br />
other purposes<br />
Scoping for point-of-sale devices<br />
Technical requirements for clear floor<br />
space<br />
Exception 11B-707.2 Exception Exception for drive-up only machines<br />
1117B.7.3 Operable parts. 11B-707.3 Operable Parts Technical requirements for operable parts<br />
Exception 11B-707.3 Exception Exception for drive-up only machines<br />
1117B.7.3.1 (clear key)<br />
• 11B-707.5 Speech Output<br />
• 11B-707.6.1 Input Controls<br />
• 11B-707.6.3.2 Tactile<br />
Symbols<br />
Technical requirements for operable parts<br />
discernible by sound or <strong>to</strong>uch<br />
1117B.7.4 Privacy. 11B-707.4 Privacy Technical requirements for same degree<br />
of privacy of input and output<br />
1117B.7.5 Speech output. 11B-707.5 Speech Output Technical requirements for speech output<br />
Exception 1 11B-707.5, Exception 1 Technical requirements for speech output<br />
Cross Reference Guide - <strong>2010</strong> <strong>CBC</strong> <strong>to</strong> <strong>2013</strong> <strong>CBC</strong> Page 58 of 114<br />
Section 1117B Other Building Components July 1, 2015