<strong>2010</strong> <strong>CBC</strong> Chapter 11B <strong>2013</strong> <strong>CBC</strong> Chapter 11B Comments<br />
1133B.2.3.3 Revolving doors.<br />
11B-404.2.1 Revolving Doors,<br />
Gates and Turnstiles<br />
Technical requirements for doors –<br />
revolving doors shall not be part of an<br />
accessible route<br />
1133B.2.3.4 Turnstiles, rails and<br />
pedestrian controls.<br />
Exception<br />
1133B.2.4 Floor level at doors.<br />
11B-206.3 Location<br />
• 11B-202.3 Alterations.<br />
Exception 2. Technically<br />
Infeasible.<br />
• 11B-202.4 Path of Travel<br />
Requirements in Alterations,<br />
Additions and Structural<br />
Repairs. Exception 8.<br />
11B-404.2.4.4 Floor or Ground<br />
Surface<br />
Scoping for location of accessible route <strong>to</strong><br />
coincide with or be located in the same<br />
area as general circulation paths.<br />
The Unreasonable Hardship exceptions for<br />
specific situations are replaced by<br />
provisions for technical infeasibility and an<br />
unreasonable hardship for path of travel<br />
improvements. These exceptions must be<br />
developed by the applicant on a case-bycase<br />
basis for submission <strong>to</strong> the enforcing<br />
authority for its consideration and, if<br />
approved, documentation <strong>to</strong> its file.<br />
Technical requirements for doors -<br />
1133B.2.4.1 Thresholds. 11B-404.2.5 Thresholds Technical requirements for doors –<br />
thresholds<br />
1133B.2.4.2 Maneuvering<br />
clearances at doors.<br />
Exception<br />
1133B.2.4.3<br />
1133B.2.4.4<br />
1133B.2.4.5 Recessed doors.<br />
1133B.2.5 Door opening force.<br />
• 11B-404.2.4 Maneuvering<br />
Clearances<br />
• 11B-404.2.4.4 Floor or<br />
Ground Surface<br />
• 11B-404.2.4 Maneuvering<br />
Clearances<br />
• 11B-404.2.4.4 Floor or<br />
Ground Surface<br />
• 11B-404.2.4 Maneuvering<br />
Clearances<br />
11B-404.2.6 Doors in Series<br />
and Gates in Series<br />
11B-404.2.4.3 Recessed Doors<br />
and Gates<br />
11B-404.2.9 Door and Gate<br />
Opening Force<br />
Technical requirements for doors –<br />
maneuvering clearances at swinging<br />
doors, doorways without doors, sliding<br />
doors and folding doors<br />
Technical requirements for doors –<br />
maneuvering clearances at swinging<br />
doors, doorways without doors, sliding<br />
doors and folding doors<br />
Technical requirements for doors –<br />
maneuvering clearances at swinging<br />
doors, doorways without doors, sliding<br />
doors and folding doors<br />
Technical requirements for doors – doors<br />
in series<br />
Technical requirements for doors –<br />
recessed doors<br />
Technical requirements for doors –<br />
opening force<br />
Amendment clarifies requirements for<br />
door and gate opening force.<br />
1. 11B-404.2.9, Item 3 Technical requirements for doors –<br />
opening force for required fire doors<br />
Cross Reference Guide - <strong>2010</strong> <strong>CBC</strong> <strong>to</strong> <strong>2013</strong> <strong>CBC</strong> Page 86 of 114<br />
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel July 1, 2015