<strong>2010</strong> <strong>CBC</strong> Chapter 11B <strong>2013</strong> <strong>CBC</strong> Chapter 11B Comments<br />

Exception 1 11B-504.5, Exception Exception for existing buildings<br />

Exception 2<br />

Exception 3<br />

• 11B-202.3 Alterations.<br />

Exception 2. Technically<br />

Infeasible.<br />

• 11B-202.4 Path of Travel<br />

Requirements in Alterations,<br />

Additions and Structural<br />

Repairs. Exception 8.<br />

• 11B-202.3 Alterations.<br />

Exception 2. Technically<br />

Infeasible.<br />

• 11B-202.4 Path of Travel<br />

Requirements in Alterations,<br />

Additions and Structural<br />

Repairs. Exception 8.<br />

The Unreasonable Hardship exceptions for<br />

specific situations are replaced by<br />

provisions for technical infeasibility and an<br />

unreasonable hardship for path of travel<br />

improvements. These exceptions must be<br />

developed by the applicant on a case-bycase<br />

basis for submission <strong>to</strong> the enforcing<br />

authority for its consideration and, if<br />

approved, documentation <strong>to</strong> its file.<br />

The Unreasonable Hardship exceptions for<br />

specific situations are replaced by<br />

provisions for technical infeasibility and an<br />

unreasonable hardship for path of travel<br />

improvements. These exceptions must be<br />

developed by the applicant on a case-bycase<br />

basis for submission <strong>to</strong> the enforcing<br />

authority for its consideration and, if<br />

approved, documentation <strong>to</strong> its file.<br />

1133B.5 Ramps. • 11B-402.2 Components<br />

• 11B-405 Ramps<br />

General technical requirements for ramps<br />

1133B.5.1 General.<br />

• 11B-403.3 Slope<br />

• 11B-405.1 General<br />

Technical requirements for ramps - slope<br />

1133B.5.2 Width 11B-405.5 Clear Width Technical requirements for ramps - width<br />

1133B.5.3 Slope.<br />

• 11B-405.2 Slope<br />

• 11B-405.6 Rise<br />

Technical requirements for ramps –<br />

maximum slope and rise<br />

1133B.5.3.1 11B-405.3 Cross Slope Technical requirements for ramps –<br />

maximum cross slope<br />

1133B.5.4 Landings.<br />

1133B.5.4.1 Location of<br />

landings.<br />

1133B.5.4.2 Size of <strong>to</strong>p and<br />

bot<strong>to</strong>m landings.<br />

1133B.5.4.3 Doors at ramp<br />

landings.<br />

• 11B-405.7 Landings<br />

• 11B-405.7.1 Slope<br />

• 11B-405.6 Rise<br />

• 11B-405.7 Landings<br />

• 11B-405.7.2 Width<br />

• 11B-405.7.2.1 (Top landings)<br />

• 11B-405.7.3 Length<br />

• 11B-405.7.3.1 (Bot<strong>to</strong>m<br />

landings)<br />

11B-405.7.5 Doorways<br />

Technical requirements for ramp landings<br />

– general requirement for level landings<br />

Technical requirements for ramp landings<br />

– <strong>to</strong>p and bot<strong>to</strong>m landings at each ramp<br />

run, rise of any ramp run not <strong>to</strong> exceed<br />

30” maximum<br />

Technical requirements for ramp landings<br />

– dimensions of <strong>to</strong>p and bot<strong>to</strong>m landings<br />

Technical requirements for ramp landings<br />

– doors at landings<br />

Cross Reference Guide - <strong>2010</strong> <strong>CBC</strong> <strong>to</strong> <strong>2013</strong> <strong>CBC</strong> Page 90 of 114<br />