<strong>2010</strong> <strong>CBC</strong> Chapter 11B <strong>2013</strong> <strong>CBC</strong> Chapter 11B Comments<br />

2. Alternate roll-in shower 60<br />

inches minimum in width . . .<br />

11B-608.2.3 Alternate Roll-In<br />

Type Shower Compartment<br />

Technical requirements for alternate rollin<br />

type shower compartments<br />

3. Alternate roll-in shower<br />

with optional enclosure . . .<br />

• 11B-608.2.3 Alternate Roll-In<br />

Type Shower Compartment<br />

• 11B-608.8 Shower<br />

Enclosures<br />

Technical requirements for alternate rollin<br />

type shower compartments applicable<br />

1115B.4.4.2 Thresholds. 11B-608.7 Thresholds Technical requirements for thresholds<br />

1115B.4.4.3 Orientation. 11B-213.3.6 Bathing Facilities Scoping requirement for orientation<br />

1115B.4.4.4 Water controls. 11B-608.5 Controls Technical requirements for controls<br />

1. Controls in a . . . roll-in<br />

shower . . .<br />

2. Controls in an . . .<br />

alternate roll-in shower . . .<br />

3. Controls in an . . .<br />

alternate roll-in shower . . .<br />

with optional enclosure . . .<br />

1115B.4.4.5 Hand-held sprayer<br />

unit.<br />

1. The hand-held sprayer<br />

unit . . .<br />

2. The hand-held sprayer<br />

unit . . . in an . . . alternate<br />

roll-in shower . . .<br />

3. The hand-held sprayer<br />

unit . . . in an . . . alternate<br />

roll-in shower . . . with<br />

optional enclosure . . .<br />

1115B.4.4.6 Sprayer unit<br />

alternative.<br />

1115B.4.4.7 Floor slope.<br />

1115B.4.4.8 Shower<br />

accessories.<br />

11B-608.5.2 Standard Roll-In<br />

Type Shower Compartments<br />

11B-608.5.3 Alternate Roll-In<br />

Type Shower Compartments<br />

11B-608.5.3 Alternate Roll-In<br />

Type Shower Compartments<br />

11B-608.6 Shower Spray Unit<br />

and Water<br />

11B-608.5.2 Standard Roll-In<br />

Type Shower Compartments<br />

11B-608.5.3 Alternate Roll-In<br />

Type Shower Compartments<br />

11B-608.5.3 Alternate Roll-In<br />

Type Shower Compartments<br />

11B-608.6 Exception<br />

11B-608.9 Shower Floor or<br />

Ground Surface<br />

11B-608.1 General<br />

Technical requirements for controls in<br />

standard roll-in type shower<br />

compartments<br />

Technical requirements for controls in<br />

alternate roll-in type shower<br />

compartments<br />

Technical requirements for controls in<br />

alternate roll-in type shower<br />

compartments applicable<br />

Technical requirements for shower sprays<br />

in standard roll-in type shower<br />

compartments<br />

Technical requirements for shower sprays<br />

in alternate roll-in type shower<br />

compartments<br />

Technical requirements for shower sprays<br />

in alternate roll-in type shower<br />

compartments applicable<br />

Exception permitted in areas subject <strong>to</strong><br />

excessive vandalism only<br />

Technical requirements for shower floor<br />

surface<br />

General scoping for showers<br />

1. A folding seat . . . • 11B-608.4 Seats<br />

• 11B-610.3 Shower<br />

Compartment Seats<br />

Technical requirements for seats<br />

Cross Reference Guide - <strong>2010</strong> <strong>CBC</strong> <strong>to</strong> <strong>2013</strong> <strong>CBC</strong> Page 44 of 114<br />