Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Timken</strong> ® SAF SPLIT-BLOCK HOUSED UNITS<br />
Spherical Roller Bearings • 230 SERIES (230K SERIES SAF, SDAF)<br />
230 Series B<br />
R<br />
(230K Series SAF, SDAF)<br />
• Bearings are available with a tapered bore for adapter-type<br />
mounting. To order, add<br />
R<br />
the suffix K to bearing number<br />
R R<br />
(e.g., 23120K). D d d a<br />
D a<br />
D d D d<br />
• Consult your <strong>Timken</strong> engineer and www.timken.com for<br />
up-to-date information about the availability of the bearings<br />
you have selected.<br />
B<br />
B<br />
R<br />
R<br />
R<br />
dD a<br />
Dd<br />
a<br />
d a<br />
D a<br />
B<br />
R<br />
d a<br />
D a<br />
D d<br />
R<br />
B<br />
R<br />
dD a<br />
dD a<br />
R<br />
B<br />
D d<br />
BR<br />
R<br />
d a<br />
D a<br />
R<br />
d a<br />
D a<br />
D d D<br />
EJ<br />
EJEM/YM<br />
EJ<br />
EJ<br />
EM/YM<br />
EM/YM<br />
EMB/YMB<br />
EM/YMEMB/YMB<br />
E<br />
Bearing<br />
Part<br />
No.<br />
23024<br />
24024<br />
23026<br />
23028<br />
23030<br />
23032<br />
23034<br />
23036<br />
23038<br />
23040<br />
23044<br />
23048<br />
23052<br />
23056<br />
Equivalent Radial Load<br />
Factors (2)<br />
Dynamic Static<br />
Mounting Data<br />
Bearing Dimensions Load Ratings<br />
Cage<br />
Type Fillet (1) Backing Dia.<br />
__ F a F ≤ e __ a > e In<br />
Fr Fr All<br />
(Max.)<br />
Bore O.D. Width Dynamic Static Shaft Housing X = 1 X = 0.67 Cases<br />
d D B C Co R d a D a e Y Y Y 0 C g<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
kN<br />
lbf.<br />
kN<br />
lbf.<br />
mm<br />
in.<br />
mm<br />
in.<br />
mm<br />
in.<br />
Geometry<br />
Factor (3)<br />
Thermal<br />
Speed<br />
Ratings (4)<br />
120 180 46 408 574<br />
2 134 167<br />
EJ<br />
0.22 3.02 4.49 2.95 0.084 3300 2700<br />
4.7244 7.0866 1.811 91700 129000 0.08 5.3 6.6 8.8<br />
120 180 60 523 762<br />
2 132 167<br />
5.2<br />
EJ<br />
0.29 2.32 3.45 2.26 0.083 2700 2200<br />
4.7244 7.0866 2.3622 117000 171000 0.08 5.2 6.6 11.4<br />
130 200 52 518 723<br />
2 146 185<br />
5.9<br />
EJ<br />
0.23 2.94 4.37 2.87 0.089 3100 2500<br />
5.1181 7.874 2.0472 116000 162000 0.08 5.8 7.3 13.0<br />
140 210 53 551 802<br />
2 158 196<br />
6.2<br />
EJ<br />
0.22 3.1 4.61 3.03 0.085 2800 2300<br />
5.5118 8.2677 2.0866 124000 180000 0.08 6.2 7.7 13.6<br />
150 225 56 621 911<br />
2 169 210<br />
7.7<br />
EJ / EM<br />
0.21 3.14 4.68 3.07 0.089 2600 2100<br />
5.9055 8.8583 2.2047 140000 205000 0.08 6.7 8.3 16.9<br />
160 240 60 705 1040<br />
2 180 224<br />
9.4<br />
EJ / EM<br />
0.22 3.12 4.65 3.05 0.093 2400 2000<br />
6.2992 9.4488 2.3622 159000 235000 0.08 7.1 8.8 20.7<br />
170 260 67 858 1250<br />
2 192 242<br />
12.8<br />
EJ / EM<br />
0.22 3.02 4.49 2.95 0.097 2200 1800<br />
6.6929 10.2362 2.6378 193000 282000 0.08 7.6 9.5 28.2<br />
180 280 74 1020 1480<br />
2 204 260<br />
16.8<br />
EJ / EM<br />
0.23 2.91 4.34 2.85 0.093 2000 1700<br />
7.0866 11.0236 2.9134 229000 332000 0.08 8 10.2 37.0<br />
190 290 75 1060 1580<br />
2 214 270<br />
17.8<br />
EJ / EM<br />
0.23 3 4.47 2.93 0.096 1900 1600<br />
7.4803 11.4173 2.9528 239000 355000 0.08 8.4 10.6 39.2<br />
200 310 82 1230 1760<br />
2 225 289<br />
22.6<br />
EJ / EM<br />
0.23 2.95 4.4 2.89 0.095 1800 1500<br />
7.874 12.2047 3.2283 276000 395000 0.08 8.9 11.4 49.7<br />
220 340 90 1340 1970<br />
2.5 247 313<br />
29.8<br />
EJ / EM<br />
0.24 2.77 4.13 2.71 0.105 1700 1400<br />
8.6614 13.3858 3.5433 300000 443000 0.1 9.7 12.3 65.6<br />
240 360 92 1400 2140<br />
2.5 267 334<br />
31.9<br />
EJ / EM<br />
0.23 2.91 4.34 2.85 0.111 1500 1300<br />
9.4488 14.1732 3.622 315000 480000 0.1 10.5 13.1 70.2<br />
260 400 104 1820 2740<br />
3 291 369<br />
47.6<br />
EJ / EMB<br />
0.24 2.85 4.24 2.78 0.078 1300 1100<br />
10.2362 15.748 4.0945 409000 617000 0.12 11.5 14.5 104.7<br />
280 420 106 1660 2790<br />
3 312 389<br />
51.0<br />
YMB<br />
0.23 2.92 4.35 2.86 0.088 1100 930<br />
11.024 16.535 4.173 373000 627000 0.12 12.3 15.3 112.2<br />
(1)<br />
Maximum shaft or housing fillet radius that bearing corners will clear.<br />
(2)<br />
These factors apply for both inch and metric calculations. See engineering section for instructions on use.<br />
(3)<br />
Geometry constant for Lubrication Life Factor a 31 is found in the Bearing Ratings section of the Engineering Manual (order no. 10424).<br />
(4)<br />
See thermal speed ratings in the Engineering Manual (order no. 10424).<br />
Note: Where EJ and EM/EMB have different load ratings, the more conservative one was taken to use for both assemblies.<br />
NOTE: Tolerance and shaft diameters are shown in the tables D-2 and D-3 on pages D-5 and D-6 as variances from nominal bearing bore.<br />
Oil<br />
RPM<br />
Grease<br />
RPM<br />
Wt.<br />
kg<br />
lbs.<br />
4.0<br />
Continued on next page.<br />
D-40 TIMKEN ® HOUSED UNIT CATALOG