<strong>Timken</strong> ® SAF SPLIT-BLOCK HOUSED UNITS<br />
LUBRICATION • SEALS • LOAD RATINGS AND LIFE<br />
LUBRICATION<br />
<strong>Timken</strong> pillow block housings are designed for grease and oil-bath<br />
lubrication. They also can be modified easily to accommodate<br />
circulating oil- or oil/air-mist systems. Grease fittings or sight<br />
gages are available upon request.<br />
A lubrication groove and oil holes are provided in the bearing<br />
outer ring. This feature, designated by adding suffix W33 to<br />
the bearing number, should be specified whenever re-ordering<br />
bearings for pillow blocks. In most cases, the fresh lubricant is fed<br />
directly to the center of the bearing between the rows of rollers<br />
and distributed to the rest of the bearing. This helps ensure the<br />
used lubricant is purged from the bearing.<br />
SEALS<br />
Precision triple-ring labyrinth seals are supplied with all <strong>Timken</strong><br />
split pillow blocks to help exclude foreign matter and retain<br />
lubricants. The pillow block base includes extra-large oil return<br />
holes at the bottom of the seal grooves to help prevent leakage<br />
past the seals.<br />
For extremely contaminated or abrasive environments, the<br />
DUSTAC seal offers protection against concentrations of dust<br />
or abrasive material that a labyrinth seal cannot keep out. See<br />
page D-80 for further information on DUSTAC.<br />
LOAD RATINGS AND LIFE<br />
Load ratings for the spherical roller bearings that are used<br />
in pillow blocks are found in the dimension tables on pages<br />
D-37 through D-43. Life calculation formulas are found in the<br />
Engineering Manual (order no. 10424) on page 48 available on<br />
www.timken.com.<br />
In addition to individual bearing selection, the ability of the pillow<br />
block to carry the operating load should be considered.<br />
It should be noted that the load rating figures supplied in this<br />
catalog are applicable only when the load direction is generally<br />
toward the base of the pillow block. If the pillow block must be<br />
mounted so the load can be applied in any other direction, consult<br />
your <strong>Timken</strong> engineer.<br />