CPT International 02/2015
The leading technical journal for the global foundry industry – Das führende Fachmagazin für die weltweite Gießerei-Industrie
The leading technical journal for the
global foundry industry – Das führende Fachmagazin für die
weltweite Gießerei-Industrie
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ELTRA<br />
Precise carbon and sulfur<br />
analysis in inorganic samples<br />
The CS-800 by Eltra, Haan, Germany,<br />
is a flexible and robust combustion<br />
analyzer for the determination of carbon<br />
and sulfur in inorganic sample<br />
materials such as steel, cast iron or cement.<br />
Organic samples like soil, graphite<br />
or chemicals can also be analyzed<br />
with the CS-800. It is equipped with<br />
a 2,500 °C induction furnace to examine<br />
the element concentrations in<br />
solids without time-consuming sample<br />
preparation. The typical analysis<br />
time is approximately 45 to 60 s.<br />
Whereas spectrometric methods require<br />
a homogeneous and plane sample<br />
surface for C/ S analysis, the CS-800<br />
also accepts samples in the form of<br />
powders, grains, drillings or broken<br />
Carbon/Sulfur Analyzer CS-800 (Photo:<br />
Eltra)<br />
pieces. Thanks to the high sample<br />
weight of up to 1 g even inhomogeneous<br />
samples can be reliably characterized.<br />
The CS-800 features up to four independent<br />
infrared measuring cells allowing<br />
for accurate analysis of low as<br />
well as high carbon and sulfur concentrations<br />
simultaneously in one measurement.<br />
The sensitivity of the IR cells<br />
can be individually configured to ensure<br />
optimum adaptation to application<br />
requirements. If the analysis involves<br />
aggressive reactive gases (for<br />
example from acidulous soil samples)<br />
the use of robust and durable gold cuvettes<br />
is an option.<br />
Benefits:<br />
» Simultaneous analysis of carbon<br />
and sulfur in a 2,500 °C induction<br />
furnace<br />
» Up to four independent infrared cells<br />
with flexible measuring ranges<br />
» Very short measurement times<br />
» High sample weights from a few milligrams<br />
to 1 gram<br />
» Flexible sample geometry<br />
» Gold IR cells (option)<br />
» Automated sample feeding (option)<br />
Hall 11, Stand H 29<br />
www.eltra.com<br />
Dross<br />
Momometer Ad_186_128.indd 1 07.05.15 08:26<br />
90 Casting Plant & Technology 2/<strong>2015</strong>