Performance Curves<br />

Filter Assembly <strong>and</strong> Element Flow Data<br />

mm (inch)<br />

Flow versus <strong>pressure</strong> drop:<br />

150 SUS (32 cSt) oil with specific gravity of ≤ 0.9<br />

(See page 5 for specific gravity corrections for <strong>pressure</strong> drop.)<br />

Single Layer with 0.7 bar (10 psi) Bypass Valve<br />

Pressure drop - bar<br />

3,0<br />

2,0<br />

1,0<br />

5<br />

0 20 40 60 80 100 120 140 160 180<br />

Flow Rate - L/min<br />

V0191 R-Pak Filter Element<br />

147 (5.8) length<br />

Pressure drop - bar<br />

0,6<br />

0,5<br />

0,4<br />

0,2<br />

0,1<br />

0<br />

0<br />

5 10 15<br />

R03<br />

R05<br />

R10<br />

20<br />

10<br />

26 EATON <strong>Low</strong> & <strong>High</strong> Pressure ProGuard <strong>Filters</strong> - OFRS-15 Series Spin-on V-FF-MC-<strong>0001</strong>-E1 June 2002<br />

8<br />

6<br />

4<br />

2<br />

Single Layer with 1.75 bar (25 psi) Bypass Valve<br />

Flow Rate - USgpm Flow Rate - USgpm<br />

10 15 20 25 30<br />

Filter assembly with<br />

25 micron element<br />

Filter assembly with<br />

40 micron element<br />

78%<br />

94%<br />

35 40 45 50<br />

0.7 bar bypass 40<br />

valve only<br />

(Blocked element)<br />

30<br />

50%<br />

61%<br />

20<br />

59%<br />

71%<br />

10<br />

3,0<br />

2,5<br />

2,0<br />

1,5<br />

1,0<br />

0,5<br />

5 10 15<br />

1.75 bar bypass<br />

valve only<br />

(Blocked element)<br />

Filter assembly with<br />

25 micron element<br />

Filter assembly with<br />

40 micron element<br />

Note:<br />

The % shown is the % of flow which<br />

passes thru a clean element with 150 SUS<br />

fluid. The remaining flow will pass thru the<br />

bypass valve without filtration.<br />

Flow Rate - USgpm<br />

10 20 30 40 50 60 70<br />

Flow Rate - L/min<br />

Pressure drop - PSID<br />

Pressure drop - PSID<br />

Pressure drop - bar<br />

0 10 20 30 40 50 60 70<br />

V0191 R-Pak Filter Element<br />

203 (8) length<br />

Pressure drop - bar<br />

0,6<br />

0,5<br />

0,4<br />

0,2<br />

0,1<br />

Flow Rate - L/min<br />

Flow Rate - USgpm<br />

10 20 30<br />

R03<br />

R05<br />

0<br />

0 20 40 60 80 100 120 140<br />

Flow Rate - L/min<br />

R10<br />

20<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

40<br />

10<br />

8<br />

6<br />

4<br />

2<br />

Pressure drop - PSID Pressure drop - PSID