021 Series Replacement Filter Elements<br />
Element Model Code<br />
V021 1 B 2 R 05<br />
1<br />
Filter element<br />
V021 - For use with HS22 <strong>and</strong><br />
OFR-S60 series filters<br />
W021 - Water Removal Element for<br />
use with HS22 <strong>and</strong> OFR-S60<br />
series filters<br />
2 Element collapse rating<br />
1 - 150 PSI<br />
286<br />
(11.30)<br />
1 2 3 4 5 6<br />
Design Specifications<br />
Rated flow: 227 L/min (60 USgpm)<br />
cannister length 1<br />
184<br />
(7.30)<br />
454 L/min (120 USgpm)<br />
cannister length 2<br />
Fluid Compatible with most<br />
Compatibility: petroleum oil, water<br />
glycol, oil-in-water <strong>and</strong><br />
water-in-oil fluids.<br />
Construction: R-Pak, W-Pak<br />
Temp range: -32°C to +107°C<br />
(-25°F to +225°F)<br />
Dimensions<br />
mm (inch)<br />
1 1 / 2"-16UN thd.<br />
126<br />
(5.00)<br />
3 Seal material<br />
B - Buna-N<br />
4 Canister length<br />
mm (inch)<br />
1 - 184 (7)<br />
2 - 286 (11)<br />
NOTE: Water removal element only available<br />
in length 2.<br />
5 Element construction<br />
R - R-Pak (grade 3, 5, 10, 20)<br />
W - W-Pak, Water Removal (grade 10)<br />
Filter Element Flow Data<br />
mm (inch)<br />
Flow versus <strong>pressure</strong> drop:<br />
150 SUS (32 cSt) oil with specific gravity of ≤ 0.9<br />
(See page 6 for viscosity corrections for <strong>pressure</strong> drop.)<br />
Pressure drop bar (PSID)<br />
Pressure drop bar (PSID)<br />
R-Pak Elements<br />
0211 R-Pak element 184mm (7.2")<br />
(6) 0.4<br />
0.3<br />
R03<br />
R05<br />
(3) 0.2<br />
0.1<br />
R10<br />
R20<br />
0<br />
0 25 50 75 100 125 150<br />
(7) (20) (33)<br />
Flow Rate - L/min (USgpm)<br />
0211 R-Pak element 286mm (11.3")<br />
(6) 0.4<br />
0.3<br />
(3) 0.2<br />
0.1<br />
R03<br />
R05<br />
R10<br />
R20<br />
0<br />
0 50 100 150 200 250 300<br />
(13) (40) (66)<br />
Flow Rate - L/min (USgpm)<br />
40 EATON <strong>Low</strong> & <strong>High</strong> Pressure ProGuard <strong>Filters</strong> - HS22 V-FF-MC-<strong>0001</strong>-E1 June 2002<br />
6 Fluid cleanliness ratings<br />
Fluid<br />
Cleanliness Element<br />
Code Code construction<br />
03 16/14/12 R-Pak<br />
05 18/16/14 R-Pak<br />
10 20/18/15 R-Pak, W-Pak<br />
20 22/19/16 R-Pak<br />
The table assumes limited<br />
ingression/single pass of pump<br />
flow through element. For detailed<br />
assistance, see “The <strong>Vickers</strong> Guide<br />
to Systemic Contamination Control”<br />
or contact your local Eaton<br />
representative.<br />
H 20-Pro Water Removing<br />
Element W0211B2W10 286 (11) length<br />
Pressure drop - bar (PSID)<br />
(25) 1,7<br />
1,4<br />
(15) 1,0<br />
0,7<br />
(5) 0,3<br />
50 100 150 200<br />
(13) (40)<br />
Flow Rate - L/min (USgpm)<br />
Note<br />
The HS22 assembly uses two<br />
filter elements in parallel. The<br />
<strong>pressure</strong> drop information is<br />
for two elements in parallel.