Model Codes<br />
Filter <strong>and</strong> Element<br />
OFRS 60 * S 1R03 PAD * 10 S50<br />
1<br />
Series designation<br />
OFRS - Oil Filter, Return line, Spin-on<br />
2<br />
Flow rating<br />
60 - 60 USgpm (227 L/min)<br />
3<br />
Mounting<br />
2 - Reservoir mount flange (outlet)<br />
Blank - Body or line mounting<br />
4<br />
Port type<br />
B - G1 1 /2 (formerly 1 /2" BSPF) thd.<br />
F - 1 1 /2" SAE 4-bolt flange<br />
P - 1 1 /2" NPTF<br />
S - 1.875-12 UN SAE-24 straight thd.<br />
for 1 1 /2" OD tube<br />
1 2 3 4 5 6 7 8 9 10 11<br />
5 Element type<br />
Canister Fluid Cleanliness<br />
Code Length<br />
mm (inch)<br />
Code<br />
1R03 - 184 (7) 16/14/12<br />
1R05 - 184 (7) 18/16/14<br />
1R10 - 184 (7) 20/18/15<br />
1R20 - 184 (7) 22/19/16<br />
2R03 - 286 (11) 16/14/12<br />
2R05 - 286 (11) 18/16/14<br />
2R10 - 286 (11) 20/18/15<br />
2R20 - 286 (11) 22/19/16<br />
2W10 - 286 (11) Water Removal<br />
The table assumes limited ingression/<br />
single pass of pump flow through<br />
element. For detailed assistance,<br />
see “The <strong>Vickers</strong> Guide to Systemic<br />
Contamination Control” or contact your<br />
local Eaton representative.<br />
Other element options:<br />
Filtration Element<br />
Code rating construction<br />
3M - 15 micron Single layer<br />
25M - 60 micron Single layer<br />
Blank - 25 micron Single layer<br />
NOTE: Because single layer elements are<br />
not assigned Fluid Cleanliness Codes,<br />
they are not eligible for <strong>Vickers</strong> Systemic<br />
Contamination Control Extended Warranty<br />
program.<br />
6 Pressure gauge option<br />
P - Pressure gauge<br />
Blank -Omit if not required<br />
36 EATON <strong>Low</strong> & <strong>High</strong> Pressure ProGuard <strong>Filters</strong> - OFRS-60 Series Spin-on V-FF-MC-<strong>0001</strong>-E1 June 2002<br />
Inlet gauge port location<br />
( 1 7<br />
/8” NPTF)<br />
A - Location A<br />
B - Location B<br />
C - Location C<br />
Blank – Omit if not required<br />
Outlet gauge port location<br />
( 1 8<br />
/8” NPTF)<br />
D - Location D<br />
E - Location E<br />
F - Location F<br />
Blank - Omit if not required<br />
NOTE: Gauges cannot be mounted side by<br />
side. If inlet <strong>and</strong> outlet gauges are required,<br />
specify non-adjacent ports such as A <strong>and</strong> E.<br />
9 Bypass valve<br />
0 - No bypass valve<br />
Blank - Bypass valve set at 25 PSI<br />
10 Design number<br />
Subject to change. Dimensions remain<br />
the same for designs 10 through 19.<br />
11 Special feature su<strong>ff</strong>ix<br />
S14 - Long 25 micron element<br />
S50 - Housing without element<br />
(omit code for element type)<br />
Blank - Omit if not required