Model Codes<br />

Filter <strong>and</strong> Element<br />

OFRS 60 * S 1R03 PAD * 10 S50<br />

1<br />

Series designation<br />

OFRS - Oil Filter, Return line, Spin-on<br />

2<br />

Flow rating<br />

60 - 60 USgpm (227 L/min)<br />

3<br />

Mounting<br />

2 - Reservoir mount flange (outlet)<br />

Blank - Body or line mounting<br />

4<br />

Port type<br />

B - G1 1 /2 (formerly 1 /2" BSPF) thd.<br />

F - 1 1 /2" SAE 4-bolt flange<br />

P - 1 1 /2" NPTF<br />

S - 1.875-12 UN SAE-24 straight thd.<br />

for 1 1 /2" OD tube<br />

1 2 3 4 5 6 7 8 9 10 11<br />

5 Element type<br />

Canister Fluid Cleanliness<br />

Code Length<br />

mm (inch)<br />

Code<br />

1R03 - 184 (7) 16/14/12<br />

1R05 - 184 (7) 18/16/14<br />

1R10 - 184 (7) 20/18/15<br />

1R20 - 184 (7) 22/19/16<br />

2R03 - 286 (11) 16/14/12<br />

2R05 - 286 (11) 18/16/14<br />

2R10 - 286 (11) 20/18/15<br />

2R20 - 286 (11) 22/19/16<br />

2W10 - 286 (11) Water Removal<br />

The table assumes limited ingression/<br />

single pass of pump flow through<br />

element. For detailed assistance,<br />

see “The <strong>Vickers</strong> Guide to Systemic<br />

Contamination Control” or contact your<br />

local Eaton representative.<br />

Other element options:<br />

Filtration Element<br />

Code rating construction<br />

3M - 15 micron Single layer<br />

25M - 60 micron Single layer<br />

Blank - 25 micron Single layer<br />

NOTE: Because single layer elements are<br />

not assigned Fluid Cleanliness Codes,<br />

they are not eligible for <strong>Vickers</strong> Systemic<br />

Contamination Control Extended Warranty<br />

program.<br />

6 Pressure gauge option<br />

P - Pressure gauge<br />

Blank -Omit if not required<br />

36 EATON <strong>Low</strong> & <strong>High</strong> Pressure ProGuard <strong>Filters</strong> - OFRS-60 Series Spin-on V-FF-MC-<strong>0001</strong>-E1 June 2002<br />

Inlet gauge port location<br />

( 1 7<br />

/8” NPTF)<br />

A - Location A<br />

B - Location B<br />

C - Location C<br />

Blank – Omit if not required<br />

Outlet gauge port location<br />

( 1 8<br />

/8” NPTF)<br />

D - Location D<br />

E - Location E<br />

F - Location F<br />

Blank - Omit if not required<br />

NOTE: Gauges cannot be mounted side by<br />

side. If inlet <strong>and</strong> outlet gauges are required,<br />

specify non-adjacent ports such as A <strong>and</strong> E.<br />

9 Bypass valve<br />

0 - No bypass valve<br />

Blank - Bypass valve set at 25 PSI<br />

10 Design number<br />

Subject to change. Dimensions remain<br />

the same for designs 10 through 19.<br />

11 Special feature su<strong>ff</strong>ix<br />

S14 - Long 25 micron element<br />

S50 - Housing without element<br />

(omit code for element type)<br />

Blank - Omit if not required