Installation Dimensions<br />
Inlet Strainer<br />
mm (inch)<br />
Minimum Screen Area<br />
Model Series cm 2 (in 2 ) A (NPTF pipe thread) B C ±3,2 (±0.125)<br />
OF3-08 710 (110) 1” 67,8 (2.67) 135,9 (5.35)<br />
OF3-10 1032 (160) 11 /4” 88,1 (3.47) 174,0 (6.85)<br />
OF3-12 2194 (340) 11 /2” 101,6 (4.00) 250,2 (9.85)<br />
OF3-16 2194 (340) 2” 101,6 (4.00) 250,2 (9.85)<br />
OF3-20 2581 (400) 21 /2” 131,3 (5.17) 256,5 (10.10)<br />
OF3-24 3226 (500) 3” 131,3 (5.17) 299,2 (11.78)<br />
Typical Installations<br />
42 EATON <strong>Low</strong> & <strong>High</strong> Pressure ProGuard <strong>Filters</strong> - OF3 Series Inlet Strainers V-FF-MC-<strong>0001</strong>-E1 June 2002<br />
C<br />
Oil level<br />
Pump intake<br />
connection<br />
Access opening should be provided so<br />
strainers can be removed for cleaning<br />
without draining fluid from tank.<br />
A<br />
Pipe joints submerged<br />
B<br />
Disconnect pipe union<br />
to remove strainers