Advanced Spring Rater - Roehrig Engineering
Advanced Spring Rater - Roehrig Engineering
Advanced Spring Rater - Roehrig Engineering
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Test Speed – velocity in in/sec of the test.<br />
Pause Time – dwell time at peak force.<br />
Measurement Interval – displacement interval between data points.<br />
<strong>Spring</strong> Height Force – The force the machine will use to define spring free height.<br />
Start/End Point – These define the range the program will use to calculate spring<br />
rate. These numbers may be changed after the test.<br />
Figure 6<br />
To continue the test, click the Start Test button.<br />
From the spring test window (Figure 7) use the Measure Gap button when the<br />
program does not have a gap measurement recorded (red light displayed). You will<br />
need to measure the gap each time you start the program. You will be prompted<br />
to enter a block height number if you are using a block between the platens when<br />
measuring the stroke.<br />
16