OPTIONAL TIMED DELAY RST-402<br />

Some materials being welded have coatings or other<br />

conditions that prevent good continuity between electrodes.<br />

For these conditions option #RST-402 will all ow the welder<br />

to be operated using TIMING rather than CONTINUITY to<br />

switch from low force to high welding force. In this case, the<br />

low force will be applied for the time set on the 4-position<br />

DETECT TIME DIPswitch, and then the high welding force<br />

will turn on. The time from initiation to high force is the SUM<br />

of the switches pushed down on top.<br />

CAUTION: When the key switch is in the TIMED<br />

position, the HIGH WELDING FORCE will turn on after<br />

the selected delay (detect) time unless initiation is<br />

opened. This will happen even if a non-conductive<br />

material or body part is between the electrodes.<br />

This option will be factory wired and supplied with the faceplate.<br />

24 | <strong>SOFT</strong> <strong>TOUCH</strong> FOR WELDERS