LATENT PRINT DEV

1,2-INDANEDIONE - CRYSTALS

Suggested use is for developing fingerprint residue (Amino

Acids) on paper and porous items including raw wood and

some currencies. 1,2 Indanedione has a high florescence

when excited by ALS in the 475-590nm range giving greater

clarity and background elimination. Saturate evidence in

1,2 Indanedione solution; allow the item to air dry inside the

fume hood. Latent prints may develop within a few hours or

may take a few days at room temperature. Greater development

may be achieved by sequencing with subsequent

applications of DFO and Ninhydrin. To speed up the development

process, apply humid heat. This is best achieved in a

humidity chamber; Ideal settings are 212oF at 80% humidity

for 15-20 minutes. A steam iron may be used being cautious

not to touch the paper or item directly with the iron as it can

scorch the item destroying the evidence. The acceptable carrier

and formulation is with 3M HFE7100. We have found 3M

HFE 7100 to be the best overall solution for penetration, ease

of use, user and environmental exposure, rapid drying times,

and quality/quantity of developed latents.

THE PROCESS

1. Saturate the Item to be processed by submerging or soaking with a float bottle application.

Spraying 1,2 Indanedione exposes the user to unnecessary risk and does not

saturate as thoroughly.

2. Allow item(s) to air dry within a vented fume hood.

3. Latent prints will begin to develop as soon as 30 minutes after treatment or may

take as long as 48 hours. The exposure to heat and humidity will usually accelerate

the process but prints have developed 24 hours or more subsequent to the heat and

humidity acceleration. As a general rule always allow your evidence 24 hours post

treatment for a complete exam.

4. Developed prints will give high fluoresce between 475nm and 590nm.

USE WITH THE DUAL77LASER

VALIDATED BY FEDERAL AGENCIES

A-2785 5 g ................................................................................................$150.52

A-2788 10 g .............................................................................................$263.43

475

NM

590

NM

FILTER

Chemical Shelf Life: 2 years

Working Solution Shelf Life: 1 year

1,2-INDANEDIONE - PREMIX

An extremely sensitive amino acid reported to develop 46%

more latents than DFO. The consistency and quality make

this the best in the industry.

A-3148B HFE-7100 base, 100 ml ...................................................$65.00

505

NM

530

NM

FILTER

POROUS

Chemical Shelf Life: 2 years

Working Solution Shelf Life: 1 year

USE WITH THE DUAL77LASER

70

CONTACT TEL: 800.953.3274 AUSTRALIAN DISTRIBUTORS, WEB: arrowheadforensics.com TACTICAL GEAR DISTRIBUTORS: E-MAIL: Email: sales@tacticalgeardistributors.com.au sales@arrowheadforensics.com