Details of operation control<br />
(1) Flap control<br />
30<br />
SRK-H<br />
Control the flap by the flap button on the wireless remote control<br />
(a) AUTO (Natural flow)<br />
The flap will be automatically set to the angle of air flow best to operation mode<br />
1) Starting time of operation<br />
In case of cooling and<br />
In case of heating<br />
sdry operation t soperation t<br />
Stops at the level<br />
position for one minute.<br />
2) When not operating<br />
(b) Memory flap<br />
Sway operation<br />
¡The flap operation as shown above<br />
will repeated.<br />
Sway operation<br />
¡ When the room temperature controller (thermostat)<br />
is activated, horizontal blowing is applied<br />
to prevent cool wind from blowing out.<br />
Air flow when flaps are used<br />
downward in heating<br />
The flap returns to the position of air flow directly below, when operation has stopped.<br />
Warm are naturally rises.<br />
Warm air is sent to the floor, creating the ideal room temperature<br />
variation is created in which the feet are warmer and<br />
the air around the head slightly cooler.<br />
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.<br />
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is<br />
started.<br />
¡ Recommendable stopping angle of the flap<br />
(c) Swing flap<br />
COOL . DRY Horizontal<br />
blowing<br />
Stops at the position<br />
for three minutes<br />
and fifty seconds<br />
Flap moves in upward and downward directions continuously.<br />
HEAT<br />
Slant forward<br />
blowing