23.12.2021 Views

potluri-unit8-final-1

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RIGID BOARD ROOF

INSULATION (MIN.

THICKNESS AS

REQ'D PER ENERGY

CODE CALCS.)

ALUM.

CURTAINWALL

SYS. WITH 1"

INSULATED

GLAZING (TYP.)

STRUCTURAL

STEEL FRAMING,

SEE STRUCTURAL

PLANS

2" PERFORATED

METAL PANEL

TRANSPARENT

SYSTEM

GLASS RAILING

STAIR SYSTEM

INTERIOR WALL GWB

3.125

ENTRY WAY - 5"

CURTAIN WALL

LINE OF EXISTING

GRADE

LINE OF EXCAVATION

CUT

UNDISTRIBUTED SOIL

aH aG aF

7' - 0" 6' - 10 1/32"

22' - 3 31/32"

aE

10' - 10"

aD aC

97' - 8"

6' - 2"

29' - 2"

aB

15' - 4"

aA

15' - 2"

20' - 2"

12' - 0"

47' - 4"

FULLY ADHERED

MEMBRANE

ROOFING

(TYP.) OVER

TAPERED

INSULATION

(1/4" SLOPE MIN.)

PRE-FINISHED

EXTRUDED ALUM.

COPING SYSTEM

EXTERIOR WALL MS

6" - ROOF PARAPET

EXTERIOR WALL MS

6"

Roof a

35' - 4"

WALL OPENING -

CURTAIN WALL 5"

2" METAL PANEL

SYSTEM

Level 2 a

20' - 2"

EXTERIOR WALL

CMU 8"

CEILING

RATED INTERIOR

WALLS MS 4.75"

Level 1 all

0' - 0"

METAL PANEL CLAD.

SYS. AT MAS. LEDGE

AT TOP OF

FOUNDATION WALL

(TYP.)

Level 0 a c

-12' - 0"

COMPACTED FILL

LTU CoAD ARC 2313

Project Source

Sheet Issued

Construction Systems 1

Poetry Foundation

06 Dec 2021 Un8

Manasa Potluri, Fall 2021

Chicago, Illinois

John Ronan

GENERAL NOTES

1

a/05/ Bldg. Section 1d "N-S, to E"/ Ext.

Enclosure/ (A301d x120)

1" = 10'-0"

1. REFER TO MATERIALS NARRATIVE FOR ADDITIONAL

INFORMATION ON TYPICAL CONDITIONS.

2. REFER TO DETAILS & OTHER DWGS. FOR MATL'S NOT

NOTED.

3. 2"METAL PANEL RAINSCREEN CLADDING SYSTEM, WITH 2"

HORIZ. METAL Z-FURRING (TYP.)

4. FLASH. SYS: SHT. MTL. FLASHING WITH DRIP, OVER

SUBSTRATE AS NOTED

7. ALUM. CURTAINWALL SYSTEM: PRE-FN. ALUM. FRAMING,

INSUL. GLASS

8. MEMB. ROOFING SYS.: FULLY ADHERED MEMBRANE

ROOFING

9. ROOFING TERMINATION SYS: SHT. MTL COUNTER- FLASHING

& EDGE TRIM

10. TAPERED ROOF INSULATION (SLOPE 1/4" MIN.)

11. RIGID BOARD ROOF INSULATION (MIN. THICKNESS AS

REQ'D PER ENERGY CODE CLACS.)

12. ALUMINUM-FRAMED SLOPED GLAZED SKYLIGHT

PLACED ON 6" CFMF CURB

13. METAL FLASHING AT SKYLIGHT CURB BASE AS PER

ROOFING MANUFACTURER'S REQUIREMENTS.

14. GC TO COORDINATE INSTALLATION OF ROOFING WITH

ROOF DRAINAGE ASSEMBLIES AND SYSTEM.

BACKFILL (TO BE

REVISED)

DRAWING LEGEND

LINE OF "PLACE-

HOLDER" OBJECT (TO

BE DEVELOPED).

AREA TO COORD.;

AREA/ITEM REVISED

(RED, THEN BLACK).

Sheet Title

Bldg. Section 1d/

Ext. Enclosure

Horiz. & Vert.

aA301d

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!