FULLY ADHERED
MEMBRANE
ROOFING SYSTEM
OVER TAPERED
INSULATION
LW 3" CONCRETE
SLAB`
18X50 STEEL BEAM
(TYP.)
30X116 STEEL BEAM
(TYP.)
a1
1' - 4"
9' - 0 7/8" 0' - 11 1/8"
1
aA554
1
aA553
15' - 2"
Roof a
35' - 4"
GENERAL NOTES
1. REFER TO MATERIALS
NARRATIVE FOR ADDITIONAL
INFORMATION ON TYPICAL
CONDITIONS.
2. REFER TO DETAILS & OTHER
DWGS. FOR MATL'S NOT
NOTED.
PRE-FINISHED
EXTRUDED ALUM.
COPING SYSTEM
EXTERIOR WALL MS
6" - ROOF PARAPET
EXTERIOR WALL MS
6"
WALL OPENING
4' - 0"
5" CURTAIN WALL
FLOOR FINISHES TO
BE DEVELOPED
W21X62 STEEL
BEAM
(TYP.)
1
aA552
Level 2 a
20' - 2"
2.5" X 5"
RECTANGULAR
MULLION
INTERIOR WALL AT
SLAB FOR
CONTINUOUS
INSULATION
2"X2" TROFFER
LIGHT
8 X 8 STEEL COLUMN
(TYP.)
EXTERIOR WALL
CMU 8"
ACOUSTIC CEILING
TILE
20' - 2"
2" METAL PANEL
SYSTEM
INTERIOR WALL
GWB 3.125
VCT FLOOR FINISH
LINE OF FINISH
GRADE
SLAB ON GRADE AT
L1
BACKFILL (TO BE
REVISED)
W18X50 STEEL BEAM
(TYP.)
W30X116 STEEL
BEAM
(TYP.)
2
aA551
Level 1 all
0' - 0"
FOUNDATION WALL
(TYP.)
ENGAGED COLUMN
CENTERED ON
COLUMN LINES (TYP.)
12' - 0"
LINE OF EXCAVATION
CUT
STRIP FOOTING
BELOW WALL
UNDISTRIBUTED SOIL
SLAB ON GRADE AT
L0 BASEMENT
1
aA551
Level 0 a c
-12' - 0"
DRAWING LEGEND
COLUMN FTG.
CENTERED BELOW
COL. (TYP.)
LINE OF "PLACE-
HOLDER" OBJECT (TO
BE DEVELOPED).
1
a/31/ Wall Section 1/ Profile "W, to N"/
Typical Wall/ (A351 x48)
1/4" = 1'-0"
AREA TO COORD.;
AREA/ITEM REVISED
(RED, THEN BLACK).
aA351
Sheet Title
Wall Section 1/
Typical Wall (x48)
Sheet Issued
06 Dec 2021 Un8
Project Source
Poetry Foundation
Chicago, Illinois
John Ronan
LTU CoAD ARC 2313
Construction Systems 1