Bill of Quantities<br />
Part 1<br />
Construction of Remaining Area of the Second Floor of the North<br />
Wing at Hebron Hospital<br />
June 2009
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
Section I - Civil Works<br />
1 Preparation Works<br />
The contractor shall visit the proposed site to<br />
familiarize himself with the required scope of work<br />
and the existing site conditions. Unit price shall<br />
include costs of the needed material and the<br />
workmanship which are required to complete the<br />
work. The price shall include costs for making the<br />
necessary temporary works to ensure the safety of<br />
the visitors of the functioning hospital and to<br />
protect the finished works rendered in the existing<br />
hospital. Price shall also include cost of hauling<br />
away the demolished material. The contractor shall<br />
preserve, protect and make the necessary works to<br />
maintain the existing electro-mechanical system to<br />
serve the functioning hospital.<br />
1.1 Carefully demolish the concrete covering steel<br />
reinforcement of the columns starters. The work<br />
includes demolishing portions of concrete<br />
parapets, walls, slabs... etc., and cleaning of steel<br />
rebars with a steel brush to remove any concrete<br />
paste, rust, stains, etc. necessary for making<br />
proper bonding and connections of the existing<br />
structural elements to the new proposed<br />
constructions. All as directed by the engineer and<br />
as shown on the drawings.<br />
1.2 Demolish and remove portion of the existing block<br />
wall between the existing corridor and the new<br />
constructed one as shown on the drawings.<br />
1.3 Dismantle, repair, paint and re-install of staircase<br />
steel door (210cm x 120cm) at the existing roof<br />
level to the roof of the new construction.<br />
1.4 Demolish and haul away the existing sloped light<br />
weight concrete layer on the existing roof<br />
according to the engineer instruction.<br />
Total of Preparation Works carried to summary:<br />
JOB 1<br />
M2 15<br />
JOB 1<br />
M2 450<br />
1
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
2 Concrete Works:<br />
Unit rates of concrete works includes supplying<br />
and casting of a ready mixed concrete. The price<br />
shall include all costs of material and workmanship<br />
for preparing the formwork, shuttering, fixing of<br />
steel reinforcement, vibration, curing making<br />
grooves and sleeves ..etc.<br />
2.1 Supply and cast concrete B300 for columns of<br />
various cross sections .<br />
2.2 Supply & cast concrete B300 for 46cm thick<br />
ribbed slabs, price includes cost of the required<br />
light weight polyester blocks "ETOLITE", and drop<br />
beams as shown on drawings.<br />
M3 27<br />
M2 235<br />
2.3 Ditto, but for 56cm thick ribbed slabs. M2 220<br />
2.4 Supply and cast of B300 for staircase flights,<br />
landings and steps .<br />
2.5 Supply and cast concrete B300 for walls 20-35cm<br />
thick.<br />
M3 9<br />
M3 17<br />
2.6 Supply and cast concrete B300 for roof parapet. M3 20<br />
2.7 Supply and cast concrete B300 for suspended<br />
solid slabs of various thickness<br />
2.8 Supply and cast concrete B300 for machine<br />
foundations including vibration insulation rubber<br />
pads... etc, as approved by the engineer.<br />
2.9 Supply of deformed high yield steel rebar<br />
reinforcement of various diameters, characteristic<br />
strength FY=4200kg/cm2 for concrete<br />
reinforcement, as shown on drawings and<br />
according to specifications. The steel<br />
reinforcement should be stored in a proper location<br />
on site as instructed by the engineer.<br />
Total of Concrete Works carried to civil<br />
summary:<br />
M3 5<br />
M3 1<br />
TON 28<br />
2
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
3 Block Works:<br />
Supply and construct hollow concrete block walls<br />
using cement and sand mortar (1:4) . The price<br />
includes cost of cutting, bonding, control and<br />
expansion joints, vertical concrete bond beams to<br />
columns or walls including steel reinforcement (of<br />
4 steel bars 12mm dia and 8mm stirrups@ 20cm<br />
c/c). All as shown on the drawings, the<br />
specifications and as directed by the engineer.<br />
3.1 Ditto, for constructing 10cm hollow concrete block<br />
walls<br />
M2 650<br />
3.2 Ditto, but 15 cm hollow concrete block . M2 220<br />
3.3 Ditto, but 20 cm hollow concrete block . M2 310<br />
3.4 Casting horizontal B300 concrete lintels or girdles<br />
above block works 20 or 10 cm thick. The price<br />
shall include the cost of steel reinforcement of<br />
4steel bars 12mm dia and 8mm stirrups@ 20cm<br />
c/c. All in accordance with the engineer's<br />
instructions, all as shown on the drawings.<br />
Total of Block Works Carried to Summary:<br />
M3 10<br />
3
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
4 Sealing Works:<br />
4.1 Supply and cast light weight sloping foam concrete<br />
layer, of density 1400kg/M3and compressive<br />
strength of 40kg/cm2, on the roof having<br />
minimum thickness of 5cm and to the required<br />
slope. Unit rate includes performing 2 cm cement<br />
screed layer and 12x12 cm cement fillet at the<br />
parapet above the light weight concrete layer to<br />
receive the water proofing membrane.<br />
4.2 Supply and install one layer of water proofing<br />
membrane 5mm thick, covered with white gravel,<br />
"Pazkar"or equally approved. The unit price shall<br />
include cost of a prime coat GS474 at a rate of<br />
0.25 kg /m2 including all the necessary material<br />
and workmanship, as specified.<br />
4.3 Supply and install sealant cover at groove" NP1 or<br />
equally approved" at roof parapet, as shown in<br />
drawings.<br />
4.4 Supply and apply three coats of hot asphalt layers<br />
(25/75) at rate of 500g/m2 for each layer,<br />
reinforced by two layers of fiberglass, and a prime<br />
coat GS474. All according to the manufacturer<br />
instructions and to the engineer's approval.<br />
4.5 Insulation of exterior walls with two layers of<br />
BONZAL sealant or equally approved. The price<br />
also include preparing the surface and applying<br />
one layer of cement and sand(2:1) plaster to<br />
receive the sealant coat.<br />
4.6 Thermal insulation of exterior walls with high<br />
density extruded polystyrene boards RANDOPAN<br />
or equally approved, 3cm thick<br />
4.7 Circular strip with foamed rubber and caulking with<br />
elastic compound for vertical and horizontal seams<br />
.<br />
4.8 Supply and install aluminum clip strip for covering<br />
vertical and horizontal expansion joints .<br />
4.9 Supply and install 2 cm extruded polystyrene for<br />
expansion joints (24 kg/m3).<br />
Total of Water Proofing carried to summary:<br />
M2 480<br />
M2 540<br />
MR 90<br />
M2 80<br />
M2 340<br />
M2 340<br />
MR 30<br />
MR 13<br />
M2 85<br />
4
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
5 Carpentry and Metal Works:<br />
All door frames of the required widths (metal or<br />
wood) shall be of formed galvanized sheet metal<br />
2mm thick. The frames shall be held in place with<br />
standard concrete filling. Door frames shall be<br />
painted using a prime coat brown unseal ZN, under<br />
coat, and the finishing coat.<br />
Wooden door leaf shall be 45mm thick with 70%<br />
fill, plywood facing on each side shall be 6mm<br />
thick, the door panels frames shall be of hard wood<br />
45*100mm.The doors shall be coated with "PVC"<br />
on both sides similar to the existing doors on the<br />
same floor or oil-based paint. Price shall include<br />
cost of the protection plates, hinges, closing<br />
mechanism, door stops, and all needed<br />
accessories. All as per drawings and the<br />
specifications.<br />
Supply and install heavy duty hinges (three 4"<br />
hinges for each door), locks and cylinders are<br />
"Yardini" or equally approved. Doors shall have 3<br />
original sub-master keys and 2 general master<br />
keys.<br />
Door handles shall be steel handles similar to<br />
those installed on the existing doors at the same<br />
floor or as approved by the engineer<br />
The "pvc" shall be 2mm thick "Tarkett Commercial<br />
" # 227 NCS 4010- B90G or equivalent applied on<br />
both sides of door panels.<br />
The thickness of the sheet metal of the fire doors<br />
shall be 1.5mm insulated with rock wool 50mm<br />
thick and density of 80-90kg/m3. The door shall<br />
include the emergency door-opening handle,<br />
fireproof locks, and hydraulic door closers made in<br />
Germany.<br />
All wooden door panels shall be furnish by oak<br />
wood frames and should be painted with 3 coats of<br />
lacquer paint.<br />
All wooden and metal door panels shall be painted<br />
with 2 coats of butty, one coat of under coat and 3<br />
coats of oil base paint.<br />
All exposed edges, louvers and door frames are<br />
oak wood and should be painted with 3 coats of<br />
lacquer paint.<br />
Rate for smoke proof doors include 100% filling,<br />
sealing strips around door panel including bottom<br />
of panel.<br />
5
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
5.1 A-Carpentry<br />
Fabricate supply and install the following wooden<br />
doors complete with all necessary fixing<br />
accessories, glazing, hinges, louvers, grills,<br />
hydraulic closures, hardware and ironmongery. All<br />
in accordance with the drawings and<br />
specifications.<br />
5.1.1 Single sealed door with fixed wooden slats<br />
120x210 cm, type N-24<br />
UNIT 12<br />
5.1.2 Single sealed door 90x210 cm, type N-45 in the list UNIT 1<br />
5.1.3 Ditto, but with a wooden louver UNIT 3<br />
5.1.4 Wooden single door 80x210 cm, type N-62in the<br />
list<br />
5.1.5 Single door + window 80x210 cm, type N-63 in the<br />
list<br />
UNIT 1<br />
UNIT 11<br />
5.1.6 Four doors closet 240x200x40 cm, type N-85 UNIT 1<br />
5.2 B. Metal Works<br />
5.2.1 Ladder anchored to the wall, type M-21 in the list UNIT 1<br />
5.2.2 Metal door , 200x40cm bent sheet 2mm thick, M-<br />
26<br />
UNIT 1<br />
5.2.3 Sheet metal door 35X200 cm type M-27 in the list UNIT 6<br />
5.2.4 Fabricate, supply and install steel cover for the<br />
main mechanical shaft at existing roof, covered<br />
with corrugated white color galvanized sheets of<br />
0.06 mm thick as per the drawings and Engineer<br />
instructions. Price to include preparing the shop<br />
drawings for approval and painting the steel of<br />
three coats of oil paint on one coat of primer.<br />
5.2.5 Fabricate, supply and install steel Fire Escape<br />
Stairs. The price shall include preparing the shop<br />
drawings for approval, steel handrail for the stairs,<br />
painting works, fastening the stairs at both ends,<br />
civil works and foundations, and all other works<br />
that might be needed as per the drawings and the<br />
Engineer instruction.<br />
5.2.6 Supply and install a staircase steel door (210cm x<br />
120cm) similar to the door installed at the existing<br />
roof level.<br />
Total of Carpentry and metal works….. carried<br />
to summary:<br />
Job 1<br />
Job 1<br />
No. 1<br />
6
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
6 Stainless Steel Works<br />
6.1 Sink and work area ,255 /60/90cm, type M-51 in<br />
the list<br />
6.2 Sink and work area ,215 /60/90cm ,type M-53* in<br />
the list<br />
UNIT 1<br />
UNIT 1<br />
6.3 Sink and work area 302/60cm ,type M-61*in the list UNIT 1<br />
6.4 Handholds for toilets for invalids, 270 cm long type<br />
M-64 in the list<br />
UNIT 28<br />
6.5 Support handles in toilets, type M-65 in the list UNIT 10<br />
6.6 Corner guard for the walls, to height 210cm ,type<br />
M-68 in the list<br />
6.7 Corner guard for the walls, 10-25cm thick, type M-<br />
69 in the list<br />
Total of Stainless Steel works….. carried to<br />
summary:<br />
7 Plastering Works:<br />
The contractor shall, when pricing this bill, take into<br />
consideration and allow for the costs or expenses<br />
of all requirements stipulated in the preambles,<br />
drawings and technical specification of the<br />
contract.<br />
7.1 Three layers of internal plastering for ceiling, walls,<br />
columns, drop beams..ets composed of a bond<br />
coat, base coat 1:4, and finish coat 1:5 as<br />
specified.<br />
7.2 External plastering for parapet, walls and wherever<br />
needed composed of 3 coats a bond coat 1:1,<br />
base coat 1:4 and finish coat 1:2 with waterproof<br />
liquid all as specified.<br />
7.3 One layer of cement plastering (Glanse) to ceiling<br />
and wall above suspended ceiling level and where<br />
ever instructed by the Engineer.<br />
Total of Plastering Works carried to Summary:<br />
UNIT 35<br />
UNIT 2<br />
M2 1320<br />
M2 90<br />
M2 400<br />
7
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
8 Flooring and Covering Works:<br />
The contractor shall, when pricing this bill, take into<br />
consideration and allow for the costs or expenses<br />
of all requirements stipulated in the preambles,<br />
drawings and technical specification of the<br />
contract.<br />
8.1 Supply and install 30x30cm terrazzo tiles similar to<br />
the floor tiles at the 2nd floor. Rate includes the<br />
supply and installation of 3 cm mortar, cement<br />
sand fill blew tiles, grouting as made by Mrfix or<br />
equally approved and polishing all in accordance<br />
with the specifications and applicable Standards.<br />
M2 290<br />
8.2 Ditto but 30 x 10 x 1 cm terrazzo tiles skirting. MR 260<br />
8.3 Supply and install 3 cm local marble (Abo<br />
alkhabaz) or equally approved thresholds 15-25<br />
cm wide, including aluminum strips<br />
8.4 Supply and install 20x20x0.8cm ceramic tile class<br />
(A) "Negev" model 9001 similar to the tile installed<br />
in existing part of the same floor. The tiles shall be<br />
laid and fixed to the walls by Mr fix bonding agents<br />
or equally approved, as specified. Price includes<br />
cost of surface preparation to receive tiles, which<br />
shall include two coats of cement plaster (scratch<br />
and float coat) and the approved adhesive<br />
materials and grouting.<br />
8.5 Ditto but installation (no supply) of green color<br />
ceramic tiles (20x20x0.8cm).<br />
8.6 Supply and install non-slip 20x20*.8cm ceramic<br />
tiles, "Negev" or equivalent class (A) for bathrooms<br />
flooring, as specified and approved by the<br />
Engineer. The price includes the mortar (1:3) the<br />
sand cement fill. The color of the tiles shall be as<br />
chosen by the Engineer.<br />
8.7 Installation of the granite porcelain tiles<br />
(30x30*.8cm), for flooring. The price to include the<br />
mortar (1:3)and the sand cement fill. (materials<br />
are available in Hospital storage)<br />
8.8 Supply and install 3cm thick local marble<br />
"Sourmaen" for stair threads 155*34*3 cm polished<br />
one face & edge . The threads should be bedded<br />
on 3cm mortar (1:3). The rate also includes cost of<br />
risers 155*13.66*2 cm and the water stop at each<br />
thread and where required<br />
8.9 Ditto but,10cm high,1cm thick for stair case skirting<br />
(triangle).<br />
M.R 22<br />
M2 470<br />
M2 17<br />
M2 40<br />
M2 115<br />
No 24<br />
MR 12<br />
8.10 Supply and install stainless steel toilet paper<br />
holders, mounted on the wall.<br />
UNIT 40<br />
8.11 Ditto but soap dishes . UNIT 40<br />
8.12 Liquid soap dispenser, model Visio soap AM or<br />
equivalent.<br />
UNIT 20<br />
8.13 Crystal mirrors, 60/45 cm. 4mm thick. UNIT 50<br />
8.14 Total of Flooring and Covering Works carried to<br />
Summary:<br />
8
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
9 Painting Works:<br />
The contractor shall, when pricing this bill, take into<br />
consideration and allow for the costs or expenses<br />
of all requirements stipulated in the preambles,<br />
drawings and technical specification of the<br />
contract.<br />
The contractor should allow in his pricing that the<br />
engineer will use as many different colors or<br />
combination of colors to meet an approved color<br />
scheme.<br />
All painting material shall be made by Tambour or<br />
equally approved<br />
9.1 Supply and apply policed paint for plastered walls<br />
and ceiling composed of one coat of primer fill<br />
and three coats of policed.<br />
9.2 Supply and apply emulsion paint for plastered<br />
walls composed of one coat of primer fill two coats<br />
putty and 3 coats of emulsion.<br />
9.3 Supply and apply oil paint for plastered walls<br />
areas composed of primer fill , two coats of putty<br />
,one coat of under coat and 3 coats of " Polyour".<br />
9.4 Painting of wall with "Acrinol" for mildew and<br />
fungus protector<br />
9.5 Painting of interior walls with a fine texture coating<br />
Tamburtext or equivalent.<br />
9.6 Painting of bare exterior concrete with Temglass,<br />
price includes preparation of the surface .<br />
Total of Painting Works carried to Summary:<br />
M2 320<br />
M2 30<br />
M2 1000<br />
M2 50<br />
M2 230<br />
M2 85<br />
9
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
10 Aluminum Works:<br />
The contractor shall, when pricing this bill, take into<br />
consideration and allow for the costs or expenses<br />
of all requirements stipulated in the preambles,<br />
drawings and technical specification of the<br />
contract.<br />
Fabricate supply and install the following<br />
aluminum doors & windows complete with<br />
vacuumed double glazing, silicone, handles and<br />
locks , all as shown in drawings and the<br />
specifications. The type, grade and colors shall<br />
match those installed in the existing part of the<br />
same floor. Shop drawings must be submitted by<br />
the contractor for the Engineer's approval. All<br />
windows and doors profiles shall be "Gonzales"<br />
product or equally approved. The unit rate shall<br />
include cost of the roller and Aluminum shutters as<br />
shown on drawings and specifications.<br />
All aluminum windows shall be 2 1/2 tracks for<br />
horizontal and vertical partitions, with screen mesh,<br />
glazing, weather strips shall be Neoprene or<br />
EPDM.<br />
10.1 Two-pane sliding window, 180/104 cm, type 20-AL<br />
in the list<br />
10.2 Window with lower part fixed, including roller<br />
shade, 180/156cm type 33AL<br />
10.3 Rail for curtain around hospital bed, 180 + 240 cm<br />
long, type 50-AL in the list.<br />
10.4 Aluminum fixed window 60x338 cm divided into<br />
four equally parts with 6mm antisun glass, type<br />
61AL in the list<br />
10.5 Screen mesh 90x90 cm for existing windows at<br />
same floor.<br />
10.6 Screen mesh 60x90 cm for existing windows at<br />
same floor.<br />
Total of Aluminum works carried to summary:<br />
UNIT 7<br />
UNIT 8<br />
UNIT 82<br />
UNIT 1<br />
UNIT 41<br />
UNIT 6<br />
10
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
11 Stone Works:<br />
The contractor shall, when pricing this bill, take into<br />
consideration the costs and expenses of all<br />
requirements stipulated in the preambles,<br />
drawings, details, and technical specification of the<br />
contract.<br />
11.1 Supply and install 5 cm thick 25 cm wide Taltish<br />
stone courses, first quality KHALET ENJASSA<br />
similar to the existing at the Northern Wing, as<br />
shown on drawings. The price also includes 15 cm<br />
thick B200 concrete backing and #8 mm steel<br />
mesh and anchoring as shown on drawings. Unit<br />
price shall also include cost of corner stones, stone<br />
grouting and pointing with white cement.<br />
11.2 Window sills of stone panels (Matabeh) 43 cm<br />
wide 8cm thick as shown on drawings.<br />
M2 300<br />
MR 30<br />
11.3 Ditto, but 38 cm wide. MR 2<br />
11.4 Window jamb with stone panels (Matabeh) 30 cm<br />
wide, 5cm thick.<br />
MR 45<br />
11.5 Ditto, but 25 cm wide. MR 8<br />
11.6 Window lintels with stone panels 30 cm wide, 5cm<br />
thick.<br />
11.7 Window lintel with stone panels 25 cm wide, 5cm<br />
thick.<br />
11.8 45cm wide stone coping 6cm thick, "mesamsem"<br />
finish<br />
Total of Stone Works carried to civil summary:<br />
MR 30<br />
MR 2<br />
MR 95<br />
11
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
12 Suspended ceiling:<br />
The contractor shall, when pricing this bill, take into<br />
consideration the costs or expenses of all<br />
requirements stipulated in the preambles,<br />
drawings and technical specification of the<br />
contract.<br />
12.1 Supply and install non perforated acoustical<br />
ceiling made of formed galvanized sheet metal<br />
trays for bathrooms and wet areas. The metal tray<br />
should be of 0.8 mm thick 45 mm high painted<br />
with polyester epoxy paint<br />
12.2 Ditto, but perforated sheets with perforation<br />
diameter 3.0mm (11% perforation). The trays<br />
should be covered with continuous and uniform<br />
manner of rock wool mats 25 mm thick of<br />
25kg/m3 density. The rock wool mats shall be<br />
wrapped by inflammable polyethylene sacks, (in<br />
accordance with the Safety Regulations and<br />
Standard).<br />
12.3 Ditto, but 60*60cm squared perforated sheets trays<br />
with perforation diameter 1.5mm (22% perforation)<br />
covered with approved acoustic material,(soundex)<br />
or equally approved<br />
12.4 Supply and install vertical & horizontal gypsum<br />
boards 12mm thick for decorative ceilings and<br />
where required.<br />
12.5 Galvanized sheet metal trays 0.6 mm thick for<br />
closing vertical walls.<br />
Total of Suspended Ceiling Works carried to<br />
Summary:<br />
M2 40<br />
M2 150<br />
M2 15<br />
M2 25<br />
M2 17<br />
12
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
13 Fixed Furniture:<br />
Fabricate, supply and install the following units, as<br />
in drawings with all fixing accessories, drawers,<br />
shelves, hardware, and iron monger with a master<br />
key .All furniture shall be made of plywood and<br />
carpenters' board 20mm maid by Etz<br />
Lavood,Sepen or equal. All edges shall be<br />
protected by oak wood strip, all in accordance with<br />
the drawings and specifications.<br />
13.1 Maternity nurses' counter, dimensions of<br />
300/60/110 cm, type N107<br />
13.2 Bottom closet with stainless steel surface + upper<br />
closet, with general dimension of<br />
255/35/60cm+255/58/90 cm, type N109 in the list.<br />
13.3 Bottom closet with stainless steel surface + upper<br />
closet, with general dimension of<br />
300/35/60cm+300/58/90cm, type N119 in the list.<br />
13.4 Bottom closet with stainless steel surface + upper<br />
closet, with general dimension of 210/35/60<br />
cm+210/58/90 cm, type N122 in the list.<br />
UNIT 1<br />
UNIT 1<br />
UNIT 1<br />
UNIT 1<br />
13.5 Storage cabinet 180/55/260 type N -124 UNIT 2<br />
13.6 Storage cabinet, 90/60/180 cm, type N128 in the<br />
list.<br />
13.7 four-door closet, 220/60/180 cm, type N130 in the<br />
list.<br />
13.8 Storage cabinet , 110/55/180 cm, type N129 in the<br />
list.<br />
13.9 Wall guard wooden 25x3 cm with 20 cm PVC 2<br />
mm thick similar to the existing wall guard at the<br />
same floor.<br />
13.10 Fabricate supply and install staircase handrail<br />
including fixing accessories, matching the existing<br />
handrail and as shown on the drawings. The rate<br />
includes surface preparation, 2 coats anti rust<br />
primer "Tambour synthetic and three coats of<br />
Tambour superlac.<br />
13.11 Wall Signs:<br />
Supply & install Aluminum wall signs (plaques) with<br />
writing in Arabic and English with a special solventproof,<br />
weather and temperature resistant fixed on<br />
the door or the wall. The price include labor work<br />
and all fixing materials.<br />
UNIT 3<br />
UNIT 1<br />
UNIT 1<br />
MR 250<br />
MR 15<br />
13.11.1 Size 25x12 cm NO 25<br />
13.11.2 Size 40x15 cm NO 5<br />
Total of Fixed Furniture carried to Summary:<br />
13
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
Section II - Mechanical Works<br />
14 Cold and Hot Water Supply System:<br />
14.1 Supply and install "Schedule 40" galvanized 1/2"<br />
pipe running along exposed or are within partitions<br />
and are fastened to the building, (or penetrate<br />
them) like ceilings, walls, bottom of suspended<br />
floors, partitions, columns, ducts, tunnels, special<br />
horizontal shats for pipes. The price includes all<br />
fasteners, supports, brackets, arches, bends,<br />
elbows, sleeves, branches, unions, all other<br />
required fittings and valves, connection with<br />
existing system, and testing. The pipes are joined<br />
by threaded joints. All done according to<br />
specifications, drawings and the approval of the<br />
Engineer.<br />
M.R 80<br />
14.2 Ditto, for 3/4" pipe. M.R 90<br />
14.3 Ditto, for 1" pipe. M.R 100<br />
14.4 Ditto, for 1.25 pipe. M.R 40<br />
14.5 Ditto, for 1.5 pipe. M.R 40<br />
14.6 Ditto, for 2" pipe. M.R 160<br />
14.7 Ditto, for 3" pipe. M.R 20<br />
14.8 Ditto, for 4"pipe. M.R 6<br />
14.9 Supply and install hot water pipe insulation as per<br />
Vidoflex or equal, 13mm thick, for 1/2" dia pipe.<br />
M.R 40<br />
14.10 Ditto, for 3/4" pipe. M.R 50<br />
14.11 Ditto, for 1" pipe. M.R 40<br />
14.12 Supply and install insulation for exposed hot water<br />
1/2" pipe, with "Vidoflex" sleeves or equally<br />
approved, 13 mm thick, wrapped with plastic tape<br />
and secured with sheet metal strip and tagged for<br />
identification. Price includes insulation of bends,<br />
branches, valves , etc.<br />
M.R 70<br />
14.13 Ditto, for 3/4" pipe. M.R 70<br />
14.14 Ditto, for 1" pipe. M.R 40<br />
14.15 Ditto, for 1.25 pipe. M.R 40<br />
14.16 Ditto, for 1.5 pipe. M.R 30<br />
14.17 Supply and install insulation for exposed hot water<br />
2" pipe, with "Vidoflex" sleeves or equally<br />
approved, 19 mm thick, wrapped with plastic tape<br />
and secured with sheathed with sheet metal strip.<br />
Price includes insulation of bends, branches,... etc.<br />
M.R 20<br />
14.18 Ditto, for 3" pipe M.R 20<br />
14.19 Supply and install pex pipe 16mm with sleeve<br />
25mm by "Aquapex" or equivalent .The price shall<br />
include all copper fittings like elbows inside walls<br />
1/2", male and female adaptors, hangers, all<br />
needed accessories for connection between<br />
copper collectors to the point. All done according<br />
to specifications, drawings and the approval of the<br />
Engineer.<br />
M.R 750<br />
14
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
14.20 Supply and install hot and cold water collectors<br />
3/4" type "Giacomini" or equivalent. Collectors are<br />
installed in the ceiling of bathrooms with all<br />
required hangers and accessories. The price<br />
should include all main valves, sub valves, vents,<br />
and all accessories<br />
EYE 15<br />
14.21 Ditto , but 1" collectors. EYE 80<br />
14.22 Supply and install bronze gate valve made by<br />
"Giacomini" or equivalent, of the following size:<br />
14.23 Ditto, 3/4" valve. UNIT 3<br />
14.24 Ditto, 1" valve. UNIT 4<br />
14.25 Ditto, 11/4"valve. UNIT 4<br />
14.26 Ditto, 1 1/2" valve. UNIT 4<br />
14.27 Ditto, 2" valve. UNIT 4<br />
14.28 Supply and install resilient butterfly type valve 3"<br />
rilsan coated and lever operated, made by<br />
"Hakohav" or equal, with flanges and counter<br />
flanges.<br />
UNIT 4<br />
14.29 Ditto, 4" valve. UNIT 2<br />
14.30 Supply and install a hose cabinet reel for fire<br />
extinguisher hose. Reel base, made of metal<br />
which can be rotated on a central shaft, on which a<br />
3/4" rubber or plastic hose 25 m long is wrapped,<br />
provided with a multi-purpose nozzle with quickopening<br />
valve, all to the approval of the Engineer<br />
and local fire department.<br />
14.31 Supply and install Fire hydrant landing valve 2"-<br />
2.5" with "Schturz" couplings for rapid hookup of<br />
fabric hose approved by Fire Service.<br />
14.32 Supply and install terilyne hose of superior quality,<br />
2" dia. X 25 m long, with multipurpose nozzle.<br />
"Schturz" couplings at both hose ends. The hose<br />
will be rolled up, tied and stored in fire fighting<br />
cabinet (price does not include cabinets).<br />
ASSY 1<br />
UNIT 1<br />
UNIT 2<br />
14.33 Supply and install 6 kg fire extinguisher. UNIT 1<br />
14.34 Supply and install sheet metal cabinet 1.5 mm<br />
thick with 80X110 cm size, oven backed paint to<br />
freely accommodate all materials described under<br />
item 14.9. The cabinet shall be painted in red and<br />
identified as "Fire Fighting Cabinet".<br />
UNIT 1<br />
14.35 Supply and install eccentric silent flush valve, by<br />
Shell or equivalent. Price includes shutoff valve,<br />
flush pipe, rubber shoe. Shutoff valve, flush pipe<br />
and brass disks to be chrome plated for suspended<br />
toilet bowl. All done as per specifications, drawings<br />
and the approval of the Engineer.<br />
14.36 Supply and install 1/2"chrome-plated hot and cold<br />
water faucet battery "Ideal Standard Slim line<br />
Model no. A5390" or equivalent, Battery of type<br />
installed on walls.<br />
UNIT 15<br />
UNIT 15<br />
14.37 Ditto, model no. A 5398 or equivalent. UNIT 4<br />
15
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
14.38 Supply and install shower Mixer unit Ideal<br />
Standard Slim line Model no. A 5394 or equivalent<br />
.<br />
14.39 Supply and install 1/2" angle valve "Giacomini" or<br />
equivalent.<br />
14.40 Supply and install Hand Spray type Grohi or<br />
equivalent and hose made by or equivalent.<br />
14.41 Supply and install Expansion connectors for water,<br />
with 0.5"- 2" tapped joints, for expansion to 30 mm,<br />
made by "Tozen'' or equivalent.<br />
UNIT 13<br />
UNIT 15<br />
UNIT 15<br />
UNIT 5<br />
14.42 Supply and install 3/4"-11/2" non-return valve. UNIT 2<br />
14.43 2" non-return valve. UNIT 3<br />
14.44 Supply and install 3/4" vent valve, made by<br />
"Giacomini" or equal.<br />
UNIT 10<br />
14.45 Ditto, but 1". UNIT 4<br />
14.46 Supply and install 3/4" - 2" safety valve. UNIT 1<br />
14.47 Supply and Install and test Domestic Pressure<br />
Booster system (Factory assembeled and<br />
Approved type "WILLO/Germany or equivalent<br />
"consisting of 2 pumps one operating and the other<br />
stand by Single stage pump with water flow of<br />
20m3/hr and 40 meter head,3 sealed Pressure<br />
Vessel with capacity of 1000 liter<br />
each,collectors,Strainers,Non return valve,Valves,2<br />
Pressure stat type "Danfuss" or equivalent,<br />
electrical control panel. the price include untivibrators<br />
base ,spring shock absorbers for each<br />
pump, all electrical and mechanical switches, wires<br />
and cables and connections needed for full<br />
installation<br />
Total of Cold and Hot Water Supply….carried to<br />
summary:<br />
JOB 1<br />
16
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
15 Wastewater and Drainage Systems:<br />
15.1 Supply and install UPVC pipes made by Al-Hilal /<br />
Egypt of size 1/14" for waste water, air<br />
conditioning drainage, and standpipes. Pipes run<br />
exposed and are fastened to walls, partitions,<br />
ceilings, shafts, suspended floors, or pipes laid<br />
within walls and under floors, Price includes all<br />
fittings, supports and fasteners, corrosion<br />
protection and 5 cm mortar over pipes under floors,<br />
connection with floor drains.<br />
M 130<br />
15.2 Ditto, but 1 1/2" dia. M 100<br />
15.3 Ditto, but 2 " dia. M 65<br />
15.2 Supply and install 4" UPVC pipe by Al-Hilal-Egypt<br />
or equivalent , running exposed along partition,<br />
false ceilings, walls, shafts, floor bottoms or laid in<br />
walls. Price includes all kind of fittings(by Al-Hilal-<br />
Egypt),supports, testing,5cm concrete layer over<br />
pipes under floors. The price should include all<br />
digging work in concrete walls and floors needed<br />
to connect with existing pipes.<br />
M 250<br />
15.3 Supply and install 4"/2" UPVC floor trap with<br />
chrome threads mesh cover 20*20cm, as per Rit or<br />
equivalent.<br />
UNIT 15<br />
15.4 Ditto but 4"/4" UPVC floor trap. UNIT 15<br />
15.5 Supply and install 4" UPVC inspection chamber<br />
with several inlets, with threaded removable<br />
hermetically closed cover of chrome 20*20cm.<br />
UNIT 3<br />
15.6 Ditto 4" clean out . UNIT 18<br />
15.7 Supply and install UPVC vent cap for 4" vent pipes. UNIT 15<br />
15.8 Supply and install 2" sink trap made of PVC by " Al-<br />
Hilal-Egypt" or equivalent.<br />
Total of Waste and Drainage Systems…carried<br />
to summary:<br />
UNIT 4<br />
17
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
16 Sanitary fixture and their Accessories:<br />
16.1 Supply and install white ceramic wash basin made<br />
by Ideal Standard SanRemo model no. E7460 or<br />
equivalent, and semi pedestal SanRemo E7492 or<br />
equivalent, installed on wall and resting on<br />
brackets.<br />
16.2 Ditto, Ideal Standard SanRemo model no. E7450<br />
or Equivalent, and semi pedestal SanRemo E7492<br />
or equivalent.<br />
assy 7<br />
assy 7<br />
16.3 Supply and install chrome-plated brass towel rack. assy 14<br />
16.4 Supply and install suspended wall hung toilet bowl<br />
by SANREMO from IS Model no. G6481 or<br />
equivalent, including PVC without cover by Ideal<br />
Standard or equivalent , all accessories, and<br />
required wall preparation.<br />
16.5 Supply and install suspended white ceramic slop<br />
sink, by" Ideal Standard" Douro model no. R3806<br />
or equivalent, and stainless steel grill type Douro<br />
model no. R6378 or equivalent, with chrom-plated<br />
fastening screws, strainer, plastic shoe.<br />
16.6 Supply and install dish washing sink type 35006 by<br />
"Twyfords", "Macintosh" or equivalent, including<br />
trap, connection to hot and cold water, mixer type<br />
Ideal Standard Slimline model no. A5396 or<br />
equivalent, including special wall consoles.<br />
16.7 Supply and install refrigerated water fountain,<br />
made by Frigeria / Italy or equivalent, of 40 liter/hr<br />
capacity, with chrom-plated push- button water<br />
faucet, compressor for cooling the water and<br />
appropriate motor rotating at 1450 rpm, a 4 liter<br />
water reservoir, connection works to water supply<br />
and connection to waste water.<br />
Total of Sanitary Fixtures and…carried to<br />
summary:<br />
assy 14<br />
assy 1<br />
assy 3<br />
assy 1<br />
18
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
17 Rainwater Drain Pipes:<br />
17.1 Supply and install high quality 4" dia. G.I. grade<br />
"B" rainwater thread jointed pipes in columns or<br />
walls. The price should include all digging works<br />
needed to connect with existing pipes, all types of<br />
fittings(elbow,T…etc)and galvanized plugs to close<br />
the existing opening.<br />
17.2 Supply and install metal rain water outlets dim. 4"<br />
with domical grade on roof with flange size 380mm<br />
by "Zurn,harmer",or equivalent.<br />
Total of Rainwater Drain Pipes…..carried to<br />
summary:<br />
18 Air Conditioning Works:<br />
18.1 Supply and install galvanized sheet metal air duct,<br />
as described, and to SMACNA standard. The price<br />
should include all wooden sleeves, all required<br />
hanger,supports,flexible connection<br />
near(AHU'S,fancoils), fire and volume dampers,<br />
and all required accessories. Price to include 1"<br />
thick fire insulation of 24 kg/m3 as per<br />
specifications.<br />
18.2 Supply and install sch-40 black steel pipe1/2" with<br />
insulation("Anabid" sleeves 19mm thick wrapped<br />
with plastic fabric secured with sheet metal<br />
strap),threaded jointing, running along or are within<br />
partition or ducts. The price includes all fasteners,<br />
supports and hanging parts as per specifications,<br />
drawings and the approval of the Engineer.<br />
M 30<br />
UNIT 4<br />
M2 200<br />
M 70<br />
18.3 Ditto but 3/4." M 75<br />
18.4 Ditto but 1". M 30<br />
18.5 Ditto but 11/4". M 45<br />
18.6 Ditto but 11/2". M 80<br />
18.7 Ditto but 2". M 690<br />
18.8 Ditto but 21/2", Jointing by welding, insulation thick<br />
25mm<br />
M 20<br />
18.9 Ditto but 3." M 150<br />
18.10 Ditto but 4". M 10<br />
18.11 Ditto but 5". M 10<br />
18.12 Ditto but 6." M 12<br />
19
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
18.13 Supply and install Galvanized sheet metal<br />
protection 0.7mm, on insulated piping and fittings<br />
of various diameters.<br />
18.14 Supply and install flexible Connection for various<br />
pipe diameters(4"-6") by "Tozen" or equal.<br />
18.15 Supply and install bronze gate valve 1" by" Crane"<br />
or equal.<br />
M 650<br />
UNIT 4<br />
UNIT 2<br />
18.16 Ditto, but 11/4". UNIT 2<br />
18.17 Ditto, but 11/2". UNIT 4<br />
18.18 Ditto, but 2". UNIT 10<br />
18.19 Ditto, but 5". UNIT 2<br />
18.20 Supply and install butterfly valve 3" with flange and<br />
opposed flange by" Hakohav" or equal.<br />
UNIT 2<br />
18.21 Ditto, but 4". UNIT 5<br />
18.22 Ditto, but 5". UNIT 2<br />
18.23 Ditto, but 6". UNIT 2<br />
18.24 Supply and install regulating bronze globe valve 2"<br />
by "Crane" or equal.<br />
UNIT 2<br />
18.25 Ditto, but 4" . UNIT 2<br />
18.26 Ditto, but 5". UNIT 2<br />
18.27 Supply and install 3- way modulating valve 1" ,<br />
including sensor, transmitter and actuator(24V)<br />
and thermostat( on -off ,3 speeds) by "Landys &<br />
Gear" or equivalent complete with all electrical<br />
works needed(material, labor).<br />
18.28 Supply and install non-return valve, 3" dia., spring<br />
loaded solid disc, by "Hakohav" or equivalent with<br />
flanges and counter- flanges, and all required<br />
fittings.<br />
UNIT 3<br />
UNIT 2<br />
18.29 Ditto, but 2" ,threaded. UNIT 2<br />
18.30 Supply and install Pressure regulating valve for 2". UNIT 2<br />
18.31 Ditto, but for 3". UNIT 2<br />
18.32 Supply and install thermometer 4" on water pipe ,<br />
by "Kobold" or equal including ball valve 1/2"for<br />
mounting and all preparation work.<br />
UNIT 4<br />
18.33 Ditto but pressure gauge. UNIT 10<br />
18.34 Supply and install Water filter, 6" dia. "Hakohav" or<br />
equal with flanges and counter-flanges.<br />
UNIT 1<br />
18.35 Ditto, but 4". UNIT 1<br />
18.36 Ditto, but 2" . Crane UNIT 2<br />
18.37 Supply and install cold forged Aluminum 4-way<br />
ceiling diffuser 6"*6" with volume damper, by<br />
"Cooling Industries" or equally equivalent.<br />
UNIT 4<br />
18.38 Ditto, but 12"*12". UNIT 8<br />
20
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
18.39 Supply and install return grill, exhaust grill with<br />
volume damper size 8"*4" by "Cooling Industries"<br />
or equal.<br />
UNIT 15<br />
18.40 Ditto, but 14"*10". UNIT 3<br />
18.41 Ditto, but 14"*12". UNIT 3<br />
18.42 Ditto, but 24"*18". UNIT 4<br />
18.43 Ditto, but 30"*8". (Provisional) UNIT 3<br />
18.44 Supply and install decorative vertical fan coil made<br />
by Carrier (France), Daikin (Japan) or equivalent,<br />
unit FC1 with cooling capacity shown on drawings,<br />
complete with painted plastic cover, washable air<br />
filter, 2 shut-off valves, drain pan, double deflection<br />
plastic grilles (manually operated) for the supply air<br />
and fixed deflection plastic grilles for the return air.<br />
The price includes thermostat (on-off ,3 - speed<br />
switch) by "Landys & Gear"or equal, and 3-way<br />
valve.<br />
The price should include also all electrical works<br />
needed (material, labor), connection with water<br />
lines and drainage.<br />
UNIT 4<br />
18.45 Ditto, but FC2. UNIT 6<br />
18.46 Ditto, but FC3. UNIT 1<br />
18.47 Supply and install ducted horizontal fan coil made<br />
by Carrier (France), Daikin (Japan) or equivalent,<br />
unit FC8 without cover with cooling capacity<br />
shown on drawing, complete with plenum,<br />
aluminum mesh flat filter, drain pan, 2 shut-off<br />
valves and hangers. The price should not include<br />
thermostat. The price should include all electrical<br />
works needed (material, labor), connecting with<br />
water and drainage lines, price to include 3-way<br />
valve.<br />
18.48 (Provisional) Supply and install complete air cooled<br />
chilling unit for 85 TR (same as installed in first<br />
stage) made by Carrier (France), Daikin (Japan) or<br />
equivalent, including condenser, screw type<br />
compressors, shock absorbers, accessories, all as<br />
described.<br />
18.49 (Provisional) Connect the above unit with existing<br />
electric switchboard and the control including all<br />
material and wiring, cabling and labor.<br />
18.50 (Provisional) Supply and install cooling/heating<br />
water pumps (same as installed in first stage) as<br />
described, by "Grundfos" or equivalent.<br />
UNIT 2<br />
UNIT 1<br />
L.S 1<br />
UNIT 1<br />
21
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
18.51 (Provisional) Connect the above unit with existing<br />
electric switchboard including all material, cabling,<br />
wiring and labor.<br />
18.52 (Provisional) Supply and Install chiller Electrical<br />
switchboard to be weatherproof including<br />
controling,all material and labor. All as per the<br />
approval of the Engineer.<br />
18.53 (Provisional) Supply and Install pumps Electrical<br />
switchboard to be weatherproof including<br />
controlling, all material and labor. All as per the<br />
approval of the Engineer.<br />
18.54 (Provisional) Supply and install hermetic expansion<br />
tank 50 lit type Reflex, Elbi or equivalent.<br />
L.S 1<br />
L.S 1<br />
L.S 1<br />
UNIT 1<br />
18.55 (Provisional) Supply and install check valve 2'' UNIT 10<br />
18.56 (Provisional) Supply and install Automatic Air Vent UNIT 4<br />
18.57 (Provisional) Supply , install and connect flow<br />
switch<br />
18.58 (Provisional) Supply and install pressure break<br />
valve for 1".<br />
18.59 (Provisional) Supply and install floating concrete<br />
base with iron profile frame, spring type shock<br />
absorbers for pumps as described.<br />
18.60 Supply, install and connect in line exhaust fan unit<br />
8" as per vortice or equivalent. Price includes<br />
propper connection with the duct system from both<br />
sides as per specifications and connection with<br />
electrical power and control as per the approval of<br />
the Engineer.<br />
UNIT 2<br />
UNIT 4<br />
UNIT 1<br />
UNIT 2<br />
18.61 Ditto, but 6" made by Vortice or equivalent. UNIT 4<br />
Total of Air Conditioning Works….carried to<br />
summary:<br />
22
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
19 Supply, install, and test Black steel gas pipes 1/2"<br />
diameter coated with extruded<br />
Polyethelene,shrinkable sleeves at threaded joints.<br />
the line to be laid at 90 cm from ground level. Price<br />
to include the excavation and backfilling with<br />
20cm sand around the gas line, compacted base<br />
coarse and asphalt.<br />
20 Medical Gas Supply:<br />
20.1 Copper pipes type (L) degreased medical oxygen<br />
compatible seamless type. The pipes must be<br />
cleaned and treated for medical gas usage<br />
including capping the ends of each pipe to ensure<br />
that no foreign bodies, dust, or vapors affect the<br />
interior of the pipes. The copper pipes must meet<br />
the international standard.<br />
ASTM B-280 and to be cleaned for medical usage<br />
(degreased) according to CE 0473. Price includes<br />
proper isolation for piping under plastering and in<br />
penetrations, hangers, brackets, fasteners, etc.., as<br />
well as various fittings and accessories needed to<br />
complete the works as shown on drawings and as<br />
per specifications. Price also includes proper<br />
flushing of the entire piping network using Nitrogen<br />
or Medical Compressed Air.<br />
Mr 70<br />
20.1.a ½ inch O.D. MR 90<br />
20.1.b 5/8 inch O.D. MR 250<br />
20.1.c 7/8 inch O.D. MR 280<br />
20.1.d 1 3/8 inch O.D. MR 100<br />
20.1.e 1 1/8 inch O.D. MR 130<br />
20.1.f 1 5/8 inch O.D. MR 30<br />
20.2 Supply and Installation of Area Valves Control<br />
Boxes:<br />
Recessed area valve control box for medical<br />
oxygen, medical compressed air and vacuum.<br />
Including 3 full-port 3-parts NIBCO shut off valves<br />
which controls the supply of gases or vacuum<br />
through the pipelines, and line pressure and<br />
vacuum gauges. The valves diameter varies<br />
between 15 up to 35 mm, as per drawings. The<br />
area valves control boxes should also include an<br />
emergency external supply port, equipped with disk<br />
and clutch mechanism for quick plug-in connection<br />
of the emergency external supply source.<br />
The front should be made of labeled transparent<br />
polycarbonate flexible unbreakable cover to ease<br />
access in emergency situation, all as per<br />
Silbermann or equally approved<br />
NO. 1<br />
23
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
20.3 Supply and Installation of bed head units:<br />
20.3.a Factory-preassembled Bed head unit for one bed,<br />
according to CE-0473, EN-46001, ISO 9001<br />
Encompassing extruded aluminum duct system,<br />
with four cavities, three of which are directly<br />
accessed using snap-on covers. Supplying<br />
electrical and lighting service, as well as medical<br />
gas service. The gas outlets should be installed in<br />
a separate compartment, The number of electrical<br />
circuits, apart of the low voltage circuit, should be<br />
three: main line power circuit, UPS power circuit,<br />
and lighting circuit, each connected to a separate<br />
terminal at the main special electrical connection<br />
compound in the bed-head unit.<br />
The bed head unit is equipped with the following<br />
services:<br />
One oxygen outlet<br />
One compressed air outlet<br />
One vacuum outlet<br />
2 electrical sockets, Main line<br />
2 electrical sockets, coded-UPS line<br />
one potential grounding socket<br />
indirect light<br />
direct light<br />
direct light (2 PL BIAX lamps)<br />
cut-off switch for direct / indirect lights<br />
one telephone socket<br />
preparation for nurse call socket<br />
The Price should include hanging rail and suction<br />
bottles bracket, complete interior wiring, cabling,<br />
piping, insulating, etc. for complete installation.<br />
The contractor must provide detailed schemes<br />
prior to supply and installation, supported with allr<br />
required conformities to standards, to be approved.<br />
NO. 2<br />
20.3.b Same as item 20.3.a, but for two beds NO. 3<br />
20.3.c Same as item 20.3.a, but for three beds NO. 7<br />
20.4<br />
Supply and installation of Local Area Pressure and<br />
Vacuum Alarm Box:<br />
local audio-visual pressure alarm box for medical<br />
oxygen, medical compressed air and vacuum to<br />
indicate pressure and vacuum failures by means of<br />
green LED, red LED, audio buzzer and pressure or<br />
vacuum gauge for each gas, as well as shut-off<br />
valves for each gas or vacuum, operated by means<br />
of one central PC card (microprocessor card) and<br />
pressure/vacuum switches for each gas, recessed<br />
type with anodized aluminum panel.<br />
Total of Medical Gas Supply…carried to<br />
summary:<br />
NO. 1<br />
24
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
Section III - Electrical Works<br />
Note: All materials and accessories to be used<br />
shall be according to the Approved<br />
Manufacturer List attached to the tender<br />
Documents, or equally approved.<br />
22 Electrical Points:<br />
a Cost of Electrical points shall include cost of<br />
connections electric supply from electrical<br />
switchboard to first point in circuit is included in the<br />
price of that point (by means of cable or leads in<br />
conduit).<br />
b Conduit and wires or cables to the points by means<br />
of or self-extinguishing conduit and cables, as req.<br />
22.1 Supply, install and connect standard lighting point<br />
(internal or external) embedded in concrete slabs<br />
or above false ceiling. Cost of the point shall<br />
include 16 mm diameter conduit or trunk, 1.5<br />
sq.mm cross-section leads or cable, lighting<br />
switches (single , double, two way or push button),<br />
outlet for luminary with junction box and terminals.<br />
Comp. 100<br />
22.2 Ditto but for emergency lighting point Comp. 20<br />
22.3 Supply, install and connect 16A wall socket points.<br />
Cost of point shall include 16 mm dia.conduit or<br />
trunks, 3x2.5mm2 leads or cables and (16 A) wall<br />
socket .<br />
Comp. 40<br />
22.4 Ditto but for fan coil units Comp. 15<br />
22.5 Ditto as item 22.1.03 but double socket. Comp. 20<br />
22.6 Ditto as item 22.1.05but with water proof double<br />
socket.<br />
Comp. 10<br />
22.7 Ditto as item 22.1.03 but with water proof cover. Comp. 10<br />
22.8 Supply, install and connect three-phase (5x16) A,<br />
single-circuit wall socket point, to include a 23 mm<br />
diameter conduit or trunk, (5x2.5) sq.mm cross<br />
section leads or cables and a (5x16) single-circuit<br />
wall socket accessory .<br />
22.9 Supply, install and connect Intercom connection<br />
point (Price includes 16 mm diameter conduit with<br />
a standard Intercom cable, leading from point to<br />
the Intercom section in LV box).<br />
22.10 Supply, install and connect Public Address System<br />
connection point (Price includes 16 mm diameter<br />
conduit with cable, leading from point to the LV box<br />
to the nearest point).<br />
22.11 Supply, install and connect Fire Alarm connection<br />
point (Price includes 16 mm diameter conduit with<br />
cable, leading from point to the LV box to the<br />
nearest point).<br />
Comp. 2<br />
Comp. 8<br />
Comp. 5<br />
Comp. 11<br />
25
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
22.12 Supply, install and connect TV connection point<br />
(Price includes 23 mm diameter conduit with<br />
cable, leading from point to the LV box).<br />
22.13 Supply, install and connect Nurse Call point (Price<br />
includes 16 mm diameter conduit with cable,<br />
leading from point to the nurse call station).<br />
22.14 Supply, install and connect computer outlet point<br />
(Price includes 16 mm diameter conduit with pull<br />
wire, leading from point to the nearest HUB in the<br />
nearest LV box).<br />
22.15 Supply, install and connect telephone socket point<br />
in 23 mm conduit including 23 mm diameter<br />
conduit from nearest telephone cabinet to<br />
accessory output in junction box, standard socket<br />
telephone accessory, and standard 2x2x.5mm2<br />
telephone lead, inserted from cabinet to accessory<br />
including connection at both ends.<br />
22.16 Supply, install and connect point for thermostat<br />
including16 mm diameter conduit installed on one<br />
side near socket for fan coils and termination with<br />
a suitable box on other side at thermostat output.<br />
3 mm thick Nylon draw-string shall be inserted<br />
inside conduit.<br />
22.17 Supply, install and connect 6 sq. mm grounding<br />
point - to include a 16 mm diameter conduit,<br />
connect at one end to grounding bus-bar in nearest<br />
switchboard, and at other end to grounded element<br />
(air-conditioning ducts, acoustic ceiling, alum.<br />
Partitions etc.<br />
22.18 Supply, install and connect emergency push-button<br />
point, to include a 16 mm diameter conduit, (3x1.5)<br />
sq.mm cross-section leads, and a dual contact<br />
emergency push-button installed in a box with<br />
frame, transparent plastic cover to be broken in<br />
case of emergency, and engraved Bakelite<br />
"sandwich" type sign, per plan (box such as<br />
TELEMENIA model ZAS-E25).<br />
22.19 Supply, install and connect point for bed head<br />
units including 3x2.5mm2 NYY cable and 23mm<br />
dia conduit from electrical switchboard to BHU<br />
junction box with all required accessories and<br />
materials.<br />
22.20 Supply, install, and connect point as above, but by<br />
a 3x1.5 sq.mm NYY cable and16mm dia conduit.<br />
22.21 Supply, install and connect point as above, but by<br />
a 6 sq.mm cross-section grounding lead and 23<br />
mm diameter conduit.<br />
22.22 Supply, install and connect point as above, but for<br />
communication, by a 23 mm conduit diameter<br />
conduit.<br />
Comp. 9<br />
Comp. 94<br />
Comp. 9<br />
Comp. 9<br />
Comp. 11<br />
Comp. 15<br />
Comp. 1<br />
No. 25<br />
No. 12<br />
No. 12<br />
No. 12<br />
26
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
22.23 Re-route existing power lines at the building to be<br />
connected to the new distribution board ( DB-2),<br />
the works shall include all necessary materials,<br />
cables, conduits, trunks and all needed civil works.<br />
22.24 Ditto as above but for general low voltage<br />
installations at the building<br />
Total of Electrical Points….carried to summary:<br />
23 Conduit, Rigid Piping and Excavation Works:<br />
Supply, install and connect Self-extinguishing type<br />
plastic conduit, processed over or under plaster or<br />
inside castings, including junction boxes, unions,<br />
connectors, etc. including galvanized draw-strings,<br />
ready for use (for works not included in points).<br />
No. 10<br />
No. 30<br />
23.1 23 mm diameter. ML 50<br />
23.2 29 mm diameter. ML 50<br />
Total of Conduit, Rigid Piping and<br />
Excv…..carried to summary:<br />
24 Cables:<br />
Supply, install and connect XLPE non-armored<br />
type thermoplastic copper cables, including<br />
insertion into conduit or attachment to structural<br />
elements or laying in ductwork, including all<br />
associated materials, insulation materials, unions,<br />
Ladders, Z Constructions, cable shoes, and<br />
connection of cable at both ends.<br />
24.1 5x16 sq.mm cross section. M.L. 60<br />
24.2 5x10 sq.mm cross section. M.L. 210<br />
24.3 5x6 sq.mm cross section. M.L. 100<br />
24.4 5x4 sq.mm cross section. M.L. 100<br />
Total of Cables ……carried to summary:<br />
27
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
25 Structural Elements, Cabinets and Ductwork:<br />
Supply, install and connect Prefabricated<br />
perforated cable tray mounted on walls or attached<br />
to ceilings. Price to include all reinforcing and<br />
attaching hardware, structural elements, brackets<br />
construction, covers were required and hangers<br />
etc.<br />
25.1 20/10 cm. M.L. 45<br />
25.2 40/10 cm. M.L. 45<br />
25.3 Ditto same as item 25.1 but 20/10 with cover M.L. 60<br />
Total of Structural Elements, Cabinets…..<br />
carried to summary:<br />
26 Grounding:<br />
26.1 Supply, install and connect Complete lightning<br />
system including exciter,120mm copper<br />
conductor, 3-earth electrodes ,earth pit and all<br />
required materials and accessories needed to<br />
complete the job as specifications and Engineer<br />
instructions.<br />
Total of Grounding …..carried to summary:<br />
27 Electrical Switchboards:<br />
a. Supply, install and connect the electrical<br />
switchboards to the site, including all associated<br />
materials and labor, as described in the technical<br />
specifications.<br />
b. Cabinets with no access from the rear, made up of<br />
transparent polycarbonate cells, or sheet-metal<br />
cabinets with a 25% surplus space.<br />
c. The switchboards are to be placed on the floor, in<br />
a niche against the wall.<br />
d. Main supply lines enter from the switchboard<br />
bottom, top or side, while outgoing lines exit the<br />
switchboard from both its bottom and top sides.<br />
e. Price to include all structural elements required in<br />
order to install the switchboard, including bus-bars,<br />
terminals, wiring, bolts, clamps, etc. and for the<br />
equipment listed below.<br />
g. Prices for supply, installation and connection of<br />
various accessories including all associated labor<br />
and materials such as bus-bars, terminals, wiring<br />
reinforcements, mounts, engraved "sandwich" type<br />
identification plates, etc. including connection to<br />
ma<br />
L.S 1<br />
27.1 Distribution Board(DB2) Unit 1<br />
Total of Electrical Switchboards…..carried to<br />
summary:<br />
28
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
28 Luminaries Supply and Installation:<br />
a. Supply and installation of Lighting fixtures as<br />
described below, including all necessary<br />
accessories, required in order to light it with lamps<br />
and electronic starter, complete.<br />
b. It is hereby stressed that the client is entitled to<br />
furnish all or part of the luminaries through other<br />
supply sources.<br />
c. All lamps shall be of the energy-saving type (18,36,<br />
58 Watts).<br />
28.1 Type (A) 2x36W fluorescent light fixture Prismatic<br />
type.<br />
Unit 20<br />
28.2 Type (AE) Ditto as A but with emergency charger. Unit 14<br />
28.3 Type (B) 2D 16W Globe with opal diffuser. Unit 18<br />
28.4 Type (E) 1 x 8W fluorescent emergency exit sign<br />
luminaries with white steel body, for maintained<br />
emergency lighting of 3 hour duration, legend<br />
panels (3) included (down, left and right).<br />
28.5 Type (G) 5W Recessed night light corrosion proof<br />
IP65.<br />
28.6 Type (J) Ceiling mounted lighting 2XPL-L 11 lamp<br />
compact fluorescent with opal diffuser controller<br />
IP20.<br />
28.7 Type (K) 2x36W, fluorescent lighting fixture, ceiling<br />
mounted with prismatic diffuser ( Internal primes)<br />
IP20.<br />
Unit 1<br />
Unit 10<br />
Unit 6<br />
Unit 7<br />
28.8 Type (KE) Ditto as K but with emergency charger. Unit 8<br />
28.9 Type (L) Down light, recessed in false ceiling, with<br />
PL-C 13 W compact fluorescent energy saving<br />
lamp, cast aluminum cover and ring silver ( frosted)<br />
aluminum reflector, IP20.<br />
28.1 Type (M) 2x36W, fluorescent lighting fixture, ceiling<br />
/ pendant. Body of grey fiber-glass reinforced<br />
polyester, prismatic polycarbonate diffuser, IP54.<br />
28.11 Type (P) 4x18W, fluorescent lighting fixture,<br />
recessed in false ceiling, with prismatic diffuser (<br />
Internal primes), IP20.<br />
Unit 5<br />
Unit 3<br />
Unit 3<br />
28.12 Type(PE) as P with 3 hrs emergency kit. Unit 2<br />
Total of Luminaries Supply…carried to<br />
summary:<br />
29
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
29 Nurse Calling System:<br />
Note: All equipment items for the nurse- calling<br />
system shall be according to the approved<br />
manufacturer list.. The work to include the supply<br />
of the equipment specified, installation of same,<br />
connection, wiring, commissioning and all other<br />
details, as specified in the technical specification<br />
and drawings.<br />
29.1 Master station 30- call master. Unit 1<br />
29.2 Reset button. Unit 11<br />
29.3 Bedside call switch. Unit 31<br />
29.4 NBY-1A metal jack. Unit 31<br />
29.5 Corridor lamp. Unit 11<br />
29.6 Ceiling mount 180mm O(7-1/8"O) NB-L Unit 11<br />
29.7 Moisture resistant pull cord switch. Unit 11<br />
29.8 Power supply for the master station. Unit 1<br />
Total of Nurse Calling System…carried to<br />
summary:<br />
30 Fire Alarm System:<br />
Supply install and connect complete in place and<br />
in an operable manner the fire alarm system. The<br />
work is to include the supply of the equipment<br />
specified, installation of same connection, wiring,<br />
cables, commissioning and all of the details and<br />
connecting to the existing system as specified in<br />
the technical specifications and drawings.<br />
30.1 Maintenance work for the existing fire alarm panel,<br />
this includes changing any required equipments in<br />
side the panel and doing any required repairs for<br />
the existing lines of the existing points including<br />
changing the glass covers of the broken break<br />
glass points.<br />
Job 1<br />
30.2 Manually operated alarm call point . Unit 5<br />
30.3 Interior Alarm horn for fire detection system . Unit 2<br />
30.4 Ionization smoke detector . Unit 5<br />
30.5 Ionization heat detector . Unit 1<br />
Total of Fire Alarm System Carried to Summary:<br />
30
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
31.00 Intercom System:<br />
Note: All equipment items for the intercom system<br />
shall be according to the approved manufacturer<br />
list.. Work is to include the supply of the equipment<br />
specified installation of same, connection, wiring,<br />
commissioning and all other details, as specified in<br />
the technical specifications and drawings.<br />
31.1 Hands free master station . Unit 1<br />
31.2 Power supply adaptor . Unit 1<br />
31.3 Door phone adaptor . Unit 1<br />
31.4 Door station . Unit 1<br />
31.5 Power supply adaptor . Unit 1<br />
31.6 Door release . Unit 1<br />
31.7 AC transformer for door release . Unit 1<br />
31.8 Digital keypad . Unit 1<br />
31.9 12V AC power supply transformer Unit 1<br />
Total of Intercom System carried to summary:<br />
32 Public Address System:<br />
Supply, install, test and commission a public<br />
address system, the system shall be according to<br />
the approved manufacturer list, including all<br />
required connections with the existing system of<br />
the Hospital including all required cables and<br />
conduits complete ready for work.<br />
32.1 9/6 watt ceiling loudspeaker, 8” round with metal<br />
grille, screw mount.<br />
Total of Public Address System carried to<br />
summary:<br />
33 Telephone System:<br />
33.1 Supply install and connect main telephone cables<br />
from telephone exchange to the LV2 boxes. Rate<br />
to include 2 NO's. 25 pair cables, conduits,<br />
terminal blocks and all accessories as specified in<br />
the technical specification and drawings.<br />
33.2 Adding two internal cards type SLC8 for the<br />
existing Alcatel telephone exchange.<br />
Total of Telephone System carried to summary:<br />
Unit 10<br />
Job 1<br />
Job 1<br />
31
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Item Description Unit QTY Unit Rate Amount<br />
34 LV Boxes:<br />
34.1 Supply install and connect the following LV boxes.<br />
Rate to include all required materials, conduits,<br />
wires, cables and accessories manufacturing from<br />
galvanized sheet metal sheets, painted with the<br />
same color of the switch boards all as specified.<br />
LVB2 Approximate dim. (80x60x25) cm No. 1<br />
Total of LV Boxes carried to summary:<br />
32
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor 16 June 09<br />
Bill Description Total<br />
Section I Civil Works Summary<br />
1 Preparation Works<br />
2 Concrete Works<br />
3 Block work<br />
4 Sealing Works<br />
5 Carpentry and Metal Works<br />
6 Stainless Steel Works<br />
7 Plastering Works<br />
8 Flooring and Covering Works<br />
9 Painting Works<br />
10 Aluminum Works<br />
11 Stone Works<br />
12 Suspended ceiling<br />
13 Fixed Furniture<br />
Total of Civil Works<br />
Section II Mechanical Works Summary<br />
14 Cold and Hot Water Supply System:<br />
15 Waste and Drainage Systems:<br />
16 Sanitary fixture and their Accessories:<br />
17 Rainwater Drain Pipes:<br />
18 Air Conditioning Works:<br />
19 Gas System<br />
20 Medical Gas Supply:<br />
Total of Mechanical Works<br />
AMS<br />
Engineering Unit @ <strong>UNDP</strong>/PAPP<br />
Summary of Part 1
ATLAS # 14163 Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor 16 June 09<br />
Section III Electrical Works Summary<br />
22 Electrical Points<br />
23 Conduit, Rigid Piping and Excavation Works<br />
24 Cables<br />
25 Structural Elements, Cabinets and Ductwork<br />
26 Grounding<br />
27 Electrical Switchboards<br />
28 Luminaries Supply and Installation<br />
29 Nurse Calling System<br />
30 Fire Alarm System<br />
31 Intercom System<br />
32 Public Address System<br />
33 Telephone System<br />
34 LV Boxes<br />
Total Electrical Works<br />
NET TOTAL SUM (in words ) :<br />
SIGNED AND SEALED :<br />
AUTHOURIZED PERSON :<br />
TITLE :<br />
SIGNATURE :<br />
DATE :<br />
AMS<br />
Engineering Unit @ <strong>UNDP</strong>/PAPP<br />
Total of Part 1 (Excluding VAT)<br />
Discount %<br />
Discount Amount<br />
Net Total - Part 1 (Excluding VAT)
Bill of Quantities<br />
Part 2<br />
Rehabilitation of the X-ray Department and the Internal Medicine Ward<br />
at Hebron Hospital<br />
Prepared By<br />
Lamasat Office<br />
Architects & Interior Designers<br />
June 2009
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
Section I - Civil Works<br />
1 Demolishing & Removal Works<br />
The contractor shall visit the proposed site to familiarize<br />
himself with the required scope of work and the existing site<br />
conditions. Unit price shall include costs of the needed<br />
material and the workmanship which are required to<br />
complete the work. The price shall include costs for<br />
making the necessary temporary works to ensure the safety<br />
of the visitors of the functioning hospital and to protect the<br />
finished works rendered in the existing hospital. Price shall<br />
also include cost of hauling away the demolished material.<br />
The contractor shall preserve, protect and make the<br />
necessary works to maintain the existing electromechanical<br />
system to serve the functioning hospital. It<br />
shall be clearly understood that all salvaged materials and<br />
fittings are the property of the Hospital and must be handed<br />
over to the director of Hospital<br />
1.1 Demolishing and removal of portions of existing concrete<br />
walls to make new openings or enlarge existing opening.<br />
The unit price shall include dismantling and preserving the<br />
existing doors or windows. For details refer to drawing No.<br />
A03. All as directed by the Engineer<br />
1.2 Demolishing and removal of existing block, gypsum or<br />
wood partition walls. The unit price shall include<br />
dismantling and preserving the existing doors and windows.<br />
For details refer to drawing No. A03. All as directed by the<br />
Engineer<br />
1.3 Demolishing and removal of the existing tiles. The unit price<br />
shall include dismantling the panel tiles. All as directed by<br />
the Engineer.<br />
1.4 Careful dismantle and preserve the existing doors and<br />
frames.<br />
1.5 Chipping off and removal of existing plaster in areas<br />
specified by the Engineer and make ready to receive new<br />
plastering or tiles.<br />
Total of Demolish & Removal Works carried to civil<br />
summary:<br />
2 Block Works<br />
M2 20<br />
M2 230<br />
M2 630<br />
NO 48<br />
M2 100<br />
Supply and construct hollow concrete block (type A,<br />
compressive strength 35kg/cm2) walls using cement and<br />
sand mortar (1:4) . The price includes cost of cutting,<br />
bonding, anchoring, control and expansion joints, utilities<br />
openings, dummy columns and reinforced concrete lintels<br />
(of 4 steel bars 12mm dia and 8mm stirrups@ 20cm c/c)<br />
over doors and windows opening and accross the whole<br />
width of the wall. For more details refer to drawing No<br />
A04,A11.<br />
2.1 Ditto for 10 cm block walls M2 240<br />
2.2 Ditto, but for 15 cm block walls M2 60<br />
Total of Block Works carried to civil summary:<br />
1
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
3 Plastering Works<br />
Three layers of internal plastering 20mm thick composed of<br />
a bond coat, base coat, and finish coat, including plaster<br />
stops, corner beads, casing beads, metal laths,<br />
scaffoldings, shuttering, bonding agents and all<br />
requirements as specified.<br />
The surfaces to be plastered are to be dashed with white<br />
cement & sand mix 1:1 to from a key, allowed to harden<br />
before applying two coats: the first coat mix. 1:1:3 (cement:<br />
sand: fine aggregate) and the second coat mix 1:4:1<br />
(cement: sand: lime). The unit rate includes furnishing and<br />
installing of reinforcing wire mesh 200mm wide to all<br />
chases of electro mechanical works and to junctions of<br />
block work & concrete surfaces.<br />
3.1 For walls, columns,..etc. M2 320<br />
3.2 Two coats plaster to receive ceramic wall tiles M2 110<br />
Total of Plaster Works carried to civil summary:<br />
4 Tiling Works<br />
The contractor shall, when pricing this bill, take into<br />
consideration and allow for the costs or expenses of all<br />
requirements stipulated in the preambles, drawings and<br />
technical specification of the contract.<br />
Samples should be submitted for engineers approval<br />
This item includes spacers<br />
4.1 Supply and install 30x30x1cm Turkish "TOBRAC"or<br />
equivalent floor tiles similar to existing or equally approved.<br />
Rate includes 30cm x 10cm x 1 cm skirting, 3 cm cement<br />
sand mortar (1:3 ), sand fill materials, cuttings, fittings,<br />
trims, grouting with white cement and polishing, all in<br />
accordance with the specifications and applicable<br />
Standards. For more details refer to drawing No. A06.<br />
4.2 Corridor Walls<br />
supply and installation of 200x200x6mm high quality<br />
ceramic tiles (Negev or equally approved) laid on 10 mm<br />
thick mortar backing (1:1:4). Rates include roughening of<br />
walls and all needed preparation work to receive tiles, 2mm<br />
thick stainless steel angles to be installed on corners as per<br />
the drawings. For more details refer to drawing No. A16.<br />
4.3 WC & kitchen tiles<br />
4.3.1 To walls:<br />
200x200x6mm high quality glazed white ceramic tiles laid<br />
on 10 mm thick mortar backing (1:1:4). For more details<br />
refer to drawing No A16.<br />
4.3.2 To floor:<br />
200x200x8mm high quality no-split ceramic tiles laid on<br />
30mm thick mortar bed (1:3) on sand bed or<br />
aggregate as needed. For details refer to drawing No A06<br />
4.4 Stair treads:<br />
Supply and install 3cm thick, 35cm width and 150cm length<br />
polished local marble ( Sour Moeen or equally approved )<br />
round edge nose treads, including sand bed underlay,<br />
bedding and jointing in white cement and sand (1:4) and<br />
pointing in white or colored approved pointing material cut<br />
to size as shown on drawing No. A17 and as per the<br />
engineer's instructions. The rate includes an edge piece for<br />
water stop.<br />
2<br />
M2 630<br />
M2 640<br />
M2 130<br />
M2 160<br />
M.R 40
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
4.5 Stair risers:<br />
Supply and install 2cm thick and 150 cm length polished<br />
local marble( Sour Moeen or equally approved ) risers,<br />
bedding and jointing in white cement and sand (1:4) and<br />
pointing in white or colored approved, pointing material cut<br />
to size as shown on related details and as per the<br />
engineer's instructions & drawing No A17.<br />
4.6 Stair case skirting:<br />
1.5cm thick variable height polished local marble ( Sour<br />
Moeenor equally approved ) skirting bedding and jointing<br />
in white cement and sand (1:4) and pointing in white or<br />
colored approved pointing material cut to size as shown on<br />
drawing No A17and as per the engineer's instructions:<br />
Total of Tile Finishing carried to civil summary:<br />
5 False Ceiling Works<br />
The contractor shall, when pricing this bill ,take into<br />
consideration and allow for the costs or expenses of all<br />
requirements stipulated in the preambles drawings and<br />
technical specifications of the contract.<br />
5.1 Supply & install non perforated acoustical ceiling made of<br />
formed galvanized sheet metal trays for bathrooms and wet<br />
areas. The metal trays should be of 0.8 mm thick 45mm<br />
high coated with “pvc”200 microns thick. For details refer to<br />
drawing A05.<br />
5.2 Supply & install perforated metal sheets (20%-25%<br />
perforation). The metal trays should be covered with<br />
continuous and uniform manner of rock wool mats 25 mm<br />
thick of 25 kg\m³ density. The rock wool mats shall be<br />
wrapped by inflammable polyethylene sacks,(in accordance<br />
with the safety regulations and standards). For details refer<br />
to drawing A05.<br />
5.3 Dismantling, cleaning and re-installing existing false ceiling<br />
panels. For details refer to drawing A05.<br />
Total of False Ceiling Works carried to civil summary:<br />
3<br />
M.R 40<br />
M.R 20<br />
M2 60<br />
M2 260<br />
M2 410
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
6 Painting Works<br />
The contractor shall, when pricing this bill, take into<br />
consideration and allow for the costs or expenses of all<br />
requirements stipulated in the preambles, drawings and<br />
technical specification of the contract, including scrubing of<br />
old paint where needed.<br />
The contractor should allow in his pricing that the engineer<br />
will use as many different colors or combination of colors to<br />
meet an approved color scheme.<br />
*Colors of paint shall be coordinated with the engineer for<br />
approval.<br />
*The Contractor shall prepare 1 m2 samples for approval<br />
by the Engineer<br />
*All painting material shall be made by Tambour or equally<br />
approved<br />
6.1 Supply and apply one layer of emulsion paint to ceiling and<br />
walls above suspended ceiling level and where instructed<br />
by the engineer.<br />
6.2 Supply and apply one coat of primer fill and three coats of<br />
policed paint for plastered walls and ceiling<br />
6.3 Supply and apply one coat of primer fill, two coats of putty<br />
and three coats of emulsion paint for plastered walls<br />
M2 1340<br />
M2 190<br />
M2 3000<br />
6.4 Supply and apply oil paint for wet areas composed of<br />
primer fill ,two coats of putty, one coat of under coat, and<br />
three coats of oil paint.<br />
M2 80<br />
6.5 Painting of walls with “Acrinol” by Deluxe or equally<br />
approved for mildew and fungus protector<br />
M2 320<br />
6.6 Supply and apply oil paint for metallic surfaces "Superlac" . M2 66<br />
Total of Painting Works carried to civil summary:<br />
4
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
7 Carpentry & Joinery<br />
Note: wood works include painting, varnishing, polishing<br />
oiling & the like.<br />
7.1 Wood Doors & Frames:<br />
Fabricate, supply and fix in position the following wooden<br />
doors, flush faced on both sides with (PVC) laminate<br />
complete with and including standard pressed steel door<br />
frame fill in all voids with mortar grout, door closer, extruded<br />
aluminum kick plate, bolts, door locks by "Yale" or equally<br />
approved, door stops, heavy duty hinges, fix glass panels<br />
etc. complete as per details and door finishing schedule. (3<br />
Master keys shall be provided).<br />
7.1.1 Doors With Half Glazed:<br />
this item includes sand plast glass panels for doors.<br />
Type DR1 overall size 210x140cm NO 1<br />
7.1.2 X-Ray Rooms Doors<br />
Supply and fix in position wooden doors for X-ray rooms<br />
comprising hard wood edgings (ZAN) 75x32 lead lining<br />
5mm thick both sides, plywood face for both sides 1mm<br />
thick (PVC) laminate, 5mm thick gypsum board both sides,<br />
softwood core, extruded aluminum kick plate, complete with<br />
and including pressed steel frame filled with mortar grout,<br />
door closer, bolts, door locks by "Yale" or equally approved,<br />
door stop, heavy duty hinges, sealant, etc. as per finishing<br />
door schedule (Master key shall be provided).<br />
a Type DR2 overall size 210x120cm NO 1<br />
b Type DR3 overall size 210x110cm NO 1<br />
7.1.3 WC Doors<br />
this item including 12 cm height aluminum kick plate.<br />
a Type DR4 overall size 210x70cm NO 8<br />
b Type DR12 overall size 210x70cm NO 9<br />
7.1.4 Single Doors<br />
a Type DR5 overall size 210x80cm NO 1<br />
b Type DR6 overall size 210x85cm NO 1<br />
c Type DR7 overall size 210x90cm NO 3<br />
d Type DR8 overall size 210x100cm NO 1<br />
e Type DR9 overall size 210x110cm NO 1<br />
f Type DR10 overall size 210x115cm NO 2<br />
g Type DR11 overall size 210x135cm NO 1<br />
h Type DR13 overall size 210x80cm NO 3<br />
i Type DR14 overall size 210x95cm NO 3<br />
j Type DR15 overall size 210x100cm NO 1<br />
k Type DR16 overall size 210x110cm NO 9<br />
l Type DR17 overall size 210x115cm NO 1<br />
5
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
7.2 kitchen cupboards<br />
7.2.1 Top cupboard unit<br />
Supply And install plywood kitchen cupboard Overall size<br />
220 x 30 x 60 cm. consisting of three double aluminum<br />
doors ,17 mm plywood shelves both sides covered with<br />
Formica laminate Complete with, ironmongery, hardware,<br />
and painting.<br />
All according to drawing A14& engineer instructions<br />
Samples of Formica to be approved by the engineer<br />
7.2.2 Bottom cupboard unit<br />
Supply And install marble kitchen cupboard Overall size<br />
220 x 60 x 90 cm. consisting of two double aluminum doors<br />
,17 mm plywood shelves both sides covered with Formica<br />
laminate and a set of four aluminum face drawers,<br />
laminate cover high quality Formica ). Complete with,<br />
ironmongery, hardware, and painting.<br />
including granite counter top "Tiger eye" with top& bottom<br />
skirting, beads, polishing, routings, jointing…etc and all<br />
preparatory woks for the installation of the required sink<br />
and sanitary fixtures. Amples of Formica to be approved by<br />
the engineer All according to drawing A14 & engineer<br />
instructions.<br />
7.3 Nurses Station desk<br />
Fabricate, supply and install wooden L shape desk as per<br />
drawings and specifications, for details refer to drawing<br />
A15.<br />
7.4 Wood Frame for Reception Desk<br />
Fabricate, supply and fix in position solid zan wood frame,<br />
for details refer to drawing No A13.<br />
7.5 X-Ray Control Booth<br />
Supply and fix in position wooden control booth for X-ray<br />
room comprising lead lining 5mm thick both sides, plywood<br />
face for both sides , 11mm thick gypsum board both sides,<br />
this item including 40*40*1 cm lead- glass panel for<br />
window.<br />
7.6 Wall Protector<br />
Supply and install a wooden wall guards cut to size<br />
according to the site requirements as made by (SPM ) or<br />
equally approved by the engineer including all necessary<br />
fittings. The color will be selected by the Engineer. For<br />
details refer to drawing No A 21.<br />
Total of Carpentry & Joinery Works carried to civil<br />
summary:<br />
6<br />
NO 3<br />
NO 3<br />
M.R 3<br />
M.R 25<br />
M2 5<br />
M.R 200
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
8 Insulation Works<br />
Fluid Applied Waterproofing:<br />
All finishes shall be measured superficially net unless<br />
otherwise stated clearly.Triangular shaped fillets and<br />
cement and sand lining to gutters shall be measured in<br />
linear meter, unless otherwise stated clearly.<br />
Rates for cement and sand work shall include for :<br />
Hacking concrete, applying cement slurry or raking out<br />
joints of blockwork to form key. Application to any surface.<br />
Finish to surface, to falls, cross falls and currents forming<br />
bays including joints. Finish to edges and arises. Making<br />
good around steel sections, pipes, tubes, bars, brackets,<br />
outlets, and the like.<br />
Measurement for water proofing shall be for sectional roof<br />
area only.<br />
Rates for waterproofing and roof sheeting shall include for:<br />
Preparation of surface, cuting in edges. overlaps, priming<br />
over parapets and stub columns including forming groove<br />
to receive edge of elasticized bitumen membrane and<br />
sealing with elastic sealer. Side and end laps, fittings<br />
including bolts, hook bolts, screws and washers, Sheets of<br />
any width or length .<br />
8.1 Internal wall insulation:<br />
for details refer to drawing No. A12. M2 25<br />
WC & kitchens floor insulation<br />
8.2 Supply and apply three coats of hot asphalt layers (25\75)<br />
at rate of 500 g/m2 for each layer, reinforced by two layers<br />
of fiberglass and a prime coat GS474 .all according to the<br />
manufacture and to the engineer’s approval<br />
8.3 Supply and install one layer of water proofing membrane of<br />
bitumen rolls 5mm thick, covered with white gravel,<br />
"Pazkar"or equally approved. The unit price shall include<br />
cost of a prime coat GS474 at a rate of 0.25 kg /m2 and all<br />
sheets flashing, including all the necessary material and<br />
workmanship, as specified.<br />
This item includes dismantling and removing the existing<br />
waterproofing material and cleaning the surface on the<br />
existing roof (where needed and as directed by the<br />
engineer ) to allow for the new waterproofing works.<br />
8.4 Repair and maintenance of certain areas of the existing<br />
waterproofing. The unit rates shall include cleaning of the<br />
existing waterproofing surfaces and supply and installtion of<br />
waterproofing material.<br />
8.5 Repair and maintenance of small patches (appox.<br />
100cmx100cm) of existing waterproofing. This item to be<br />
measured by the number of patches repaired.<br />
Total of Insulation Works carried to civil summary:<br />
9 Glass Works<br />
9.1 Sekurit Glass<br />
9.1.1 Sekurit Glass Panels<br />
Supply and install 100 cm hight,1cm thick high quality<br />
sekurit glass panels, including all accessories. For more<br />
dimensions & details refer to drawing A13,A14.<br />
9.2 Sand Glass Sekurit Panels<br />
Supply and install sand plast 1cm thick sekurit glass panels<br />
for door. For more dimensions & details refer to drawing<br />
A14.<br />
Total of Glass Works carried to civil summary:<br />
7<br />
M2 80<br />
M2 500<br />
M2 50<br />
NO 15<br />
M2 12<br />
M2 1.5
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
10 Metal work<br />
10.1 ALUMINUM<br />
All the profiles must be NAPCO 7700 for sliding windows,<br />
and NAPCO 2200 for fixed windows or equally approved.<br />
Fabricate supply and fix in position the following anodized<br />
aluminum windows & doors, complete with double glazing<br />
with 6mm thick clear glass for both inner and outer panels<br />
similar to existing windows, and 12mm thick air space filled<br />
with argon gas, and butyl framing rubber, perforated<br />
aluminum frame and polysulphide mastic between<br />
aluminum frame and glass, including aluminum woven<br />
mesh fly screen, all necessary frames, sub frames, fixing,<br />
fittings, accessories weather stripping and hardware as per<br />
specifications<br />
* Shop drawings & samples to be approved by the<br />
Engineer.<br />
10.1.1 Windows<br />
For windows details refer to drawing A18.<br />
Type W1 overall size 728x60cm NAPCO 2200 or<br />
equivalent .Complete with frame, glazing, mastic sealant,<br />
ironmongery and hardware.<br />
10.1.2 Doors<br />
Emergency Door<br />
Type door ED1 overall size 228x110cm.Thickness 52 mm<br />
Weight =29 kg/m². Complete with galvanized frame,<br />
glazing, mastic sealant, paint of door and frame according<br />
to engineer instructions and approval, ironmongery and<br />
hardware and including 15mm glass vision panel for more<br />
details refer to drawing No A18<br />
10.2 Metal Cupboards<br />
Supply and install painted metal cupboards overall size<br />
200x47 x60 cm including all accessories all as per<br />
drawings and details, for details refer to drawing No A15.<br />
NO 3<br />
NO 1<br />
NO 14<br />
10.3 Wall Signs<br />
supply & install wall signs.<br />
Aluminum plaques in Arabic & English with a special<br />
solvent proof,weather and temperature resistant fixed on<br />
the door or the wall .<br />
The price include labor work and all fixing materials.<br />
a size 25x12 cm NO 40<br />
b size 40x15 cm NO 5<br />
10.4 Curtain Tracks.<br />
All the profiles shall be of Clickeze, InPro Podiatric or<br />
equally approved. This item includes overhead metal<br />
curtain track, track accessories OPTITRAC (or equivalent),<br />
extruded aluminum cubicle track with clear anodized<br />
aluminum or white baked acrylic enamel finish. Aluminum<br />
shall be 6063-T5. Dimensions: height 3/4" (19.05mm),<br />
width 13/8" (34.93mm).<br />
a Supply & install L- shape tracks for curtains around beds,<br />
420cm long.<br />
NO 12<br />
b Ditto, but 300 cm long (straight). NO 5<br />
10.5 Steel -Wood Handrail<br />
Fabricate and supply and fix in position handrail for<br />
emergency stair case as per detail No A17 and Engineer<br />
approval. This item includes wood panels and all<br />
accessories for fixing in position.<br />
Total of Metal Works carried to civil summary:<br />
8<br />
M.R 8
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
11 Sand-blasting Works<br />
This item includes cleaning of existing stone facades with<br />
dry abrasive material forced by compressed air from tank<br />
through hose and nozzle. Cleaning material must be dustfree<br />
and abrasive. Material size shall be approved by<br />
engineer. Air pressure delivered by compressor to blasting<br />
tank may range from 40 lbs. to 100 lbs. per square inch<br />
according to the first test cleaning which shall approved by<br />
the engineer. Lightly sanded, coated, slurry, should not be<br />
cleaned by sandblasting.<br />
"pre-cleaning" process includes removing all large mortar<br />
particles with hand tools before blasting. Use wooden<br />
paddle, the rough edge of a brick, or metal scrape hoe.<br />
Chisels may be used if necessary to remove hardened<br />
mortar or concrete.<br />
The contractor shall provide adequate protection for all nonmasonry<br />
surfaces adjacent to work areas, Use plastic<br />
sheeting and duct tape to protect windows, doors, etc. If<br />
possible, painting, caulking, etc. should be done after<br />
sandblast operation is completed.<br />
Sandblast Cleaning of stone facades M2 1000<br />
Total of Other Works carried to civil summary:<br />
9
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
Section II - Mechanical Works<br />
12 SANITARY SYSTEM<br />
12.1 Supply and install of UPVC, type Redi - Italy made or E.A,<br />
drainage pipes to floor drains or to existing sewage pipes<br />
with all required fittings", "T" etc. The price includes<br />
digging and plastering, incasing with concrete cover for<br />
underground pipes, connection to existing riser pipes as<br />
shown in drawings, and approval of supervisor engineer.<br />
12.1.1 size 2 inch diameter M.R 75<br />
12.1.3 size 4 inch diameter M.R 50<br />
12.2 Supply and install of CPVC - Italy made, suspended and<br />
underground condensate drainage pipes from AC units to<br />
floor drains or to existing sewage pipes with all required<br />
fittings needed for installation. The price includes digging<br />
and plastering, concrete cover for underground pipes,<br />
hangers and supports for suspended pipes, as shown in<br />
drawings, and approval of supervisor engineer.<br />
12.2.1 size 2 inch diameter M.R 90<br />
12.3 Supply and install Floor Clean Out 4"UPVC type Redi -<br />
Italy made or E.A, including chrome plated (sealed type)<br />
cover (15*15 cm) complete with connection to drain pipes<br />
as located in drawings , specifications and approval of<br />
supervisor engineer.<br />
NO 5<br />
12.4 Supply and install of polypropylene DALLMER type 54 floor<br />
drain body with trap,rodding eye,DN 50 outlet, DALLMER<br />
grating KE 15<br />
NO 2<br />
12.5 Supply and install 4" floor trap UPVC, type Redi - Italy<br />
made or E.A, include chrome plated screw type cover<br />
(15*15 cm) completed with connections to drain pipes as<br />
located in drawings, specifications and approval of<br />
supervisor engineer.<br />
NO 11<br />
12.6 Ditto but floor drain size 4"/2" diameter NO 11<br />
12.7 Dismantle all the existing sanitary fixtures with pipes<br />
networks (where required) in internal medicine ward and X-<br />
Ray Departments with all accessories and fittings as per<br />
engineer's instructions and keep safe in hospital store<br />
(where possible).<br />
JOB 1<br />
12.8 Supply and install fire glazed wall hung washbasin, white<br />
colour, of size 55*45 cm type Roca or E.A, complete with<br />
chrome plated mixer, type Hamat, 1/2" * 3/8" angle valves,<br />
supports, 2" waste outlet down to floor drain, plastic siphon<br />
trap, including connections to drain and water outlets, as<br />
shown in drawings, and approval of supervisor engineer.<br />
NO 30<br />
12.9 Supply and install fire glazed kitchen sink, white colour, of<br />
size 55*45 cm type Roca, or E.A, complete with chrome<br />
plated mixer, type Hamat, 1/2" * 3/8" angle valves,<br />
supports, 2" waste outlet down to floor drain, plastic siphon<br />
trap, including connections to drain and water outlets, as<br />
shown in drawings, and approval of supervisor engineer.<br />
12.10 Supply and install fire glazed wall mounted vitreous china<br />
water closets, white colour, type Roca or E.A, including<br />
recessed cistern type Schwab, complete with cistern,<br />
valves , fittings, solid seat and cover, toilet roll paper holder<br />
, chrome plated 1/2" stop angle valve of approved quality,<br />
chrome plated 13mm hose, including connection to drain<br />
and water outlets, plug, flexible pipe with the hand spray<br />
and all accessories for complete installation, all is<br />
according to drawings, and approval of supervisor<br />
engineer.<br />
10<br />
NO 3<br />
NO 22
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
12.11 Supply and install white glazed shower tray, white colour,<br />
type Roca or E.A, of size 90X90cm, complete with chrome<br />
plated mixers, type Hamat, plug and chain, 1.5m flexible<br />
hose with chrome lever handle and stand, and all<br />
associated water supply pipes, and brackets screwed to<br />
concrete or block work, sealing joint to worktop or wall with<br />
NO 3<br />
mastic sealant.<br />
12.12 Supply and install water mixer for shower, type Hamat, with<br />
chrome lever handle and stand. Price includes connections<br />
to supply water pipes and all accessories needed to<br />
complete the job.<br />
Total of Sanitary System Works carried to Mechanical<br />
summary:<br />
NO 2<br />
13 WATER AND FIRE FIGHTING SYSTEMS<br />
13.1 Supply and install SCH40 galvanized steel pipes<br />
(Seamless type) for domestic cold water and fire fighting<br />
systems, to be connected from the existing main supply<br />
suspended pipes in false ceiling up to copper collectors<br />
and fire hose cabinets, with all necessary fittings like<br />
valves, elbows ,tees, vents, of approved quality. The price<br />
include supports, hangers and dismantling the existing<br />
pipes (where required) as shown on drawings, and as<br />
follows:<br />
13.1.1 size 2" diameter M.R 10<br />
13.1.2 size 1 1/2" diameter M.R 40<br />
13.1.3 size 1 1/4" diameter M.R 110<br />
13.1.4 size 1" diameter M.R 30<br />
13.1.5 size 3/4" diameter M.R 30<br />
13.2 Supply and install SCH40 galvanized steel pipes<br />
(Seamless type) for domestic hot water system, to be<br />
connected from the existing main supply suspended pipes<br />
in false ceiling up to copper collectors, with all necessary<br />
fittings like valves, elbows ,tees, vents, of approved quality.<br />
The price include 13mm vidoflex or Armaflex insulation<br />
rolled by plastic bonds, supports, hangers and dismantling<br />
the existing pipes (where required) as shown on drawings,<br />
and as follows:<br />
13.2.1 size 2" diameter M.R 10<br />
13.2.2 size 1 1/2" diameter M.R 20<br />
13.2.3 size 1 1/4" diameter M.R 30<br />
13.2.4 size 1" diameter M.R 75<br />
13.2.5 size 3/4" diameter M.R 40<br />
13.2.6 size 1/2" diameter M.R 15<br />
13.3 Supply and install cold and hot water copper collectors,<br />
type Tieme or E.A with all necessary fittings, nipples, nuts,<br />
unions, brass fittings adapter, shut off valves on main and<br />
branch pipes.....etc. The price should include supplying and<br />
installing 16mm pexgol plastic pipes with its 25mm plastic<br />
conduits to be connected from the copper collectors<br />
openings up to location of sanitary fixtures outlets<br />
according to plans and engineer’s instructions.<br />
13.3.1 Collector 3/4" diameter (Unit is in collector openings) Open. 10<br />
13.3.2 Collector 1" diameter (Unit is in collector openings) Open. 66<br />
13.4 supply and install metallic painted steel cabinets of<br />
approved quality, including cover with double doors for<br />
domestic water collectors. The cabinets should be<br />
recessed in walls and fixed on wooden frame constructed<br />
in the wall. The sizes of the cabinets are as follows:<br />
13.4.1 80cm X 60cm NO 4<br />
13.4.2 60cm X 60cm NO 2<br />
13.5 Supply and install Halon Powder fire extinguisher cylinders,<br />
of approved quality. The price includes all accessories and<br />
fittings needed for installation and fixing on wall. The<br />
capacities of cylinders are as follows:<br />
11
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
13.5.1 6 kg Capacity NO 2<br />
13.5.2 3 kg Capacity NO 3<br />
13.6 Supply and install 80*80*30 cm steel fire hose reel cabinet,<br />
25mm diam., mounted on swinging reel, an angle isolation<br />
valve inside the cabinet, a jet nozzle with an incorporated<br />
cock, and 25m long textile hose. Each cabinet should be<br />
supplied with 3 kg powder fire extinguisher, as shown on<br />
drawings, and approval of supervisor engineer.<br />
NO 2<br />
Total of Water and Fire Fighting System Works carried<br />
to Mechanical summary:<br />
14 CENTRAL HEATING SYSTEM<br />
14.1 Dismantle all the existing central heating pipes networks<br />
and radiators distributed in all spaces and rooms in internal<br />
medicine ward and X-Ray Departments with all accessories<br />
and fittings as per engineer's instructions and keep safe in<br />
hospital store (where possible).<br />
14.2 Supply, install and test cast iron radiator, type Chappee, or<br />
E.A , of size 68cm, 3 section in depth (68/3). The price<br />
includes all necessary fittings, i.e shutt off and control<br />
valves, vents, hangers, reducers, chrome nipples, gaskets,<br />
plastic covers on nipples and whatever to complete the job,<br />
all is according to specifications, drawings and approval of<br />
supervisor engineer.<br />
14.3 Supply and install black steel of schedule 40 pipes for<br />
heating system, including all required insulation by vidoflex<br />
of 13mm thickness rolled by plastic bonds, sleeves, gate<br />
valves on branch pipes, automatic air vents, gav. hangers<br />
and supports, drain cocks with all required fittings and<br />
connections, all according to drawings, specifications and<br />
approval of supervisor engineer and as follows:<br />
JOB 1<br />
SEC 380<br />
14.3.1 size 1 1/2" diameter M.R 15<br />
14.3.2 size 1 1/4" diameter M.R 50<br />
14.4 Supply and install copper collectors for central heating<br />
system, type Gaicomini or E.A, with all necessary fittings,<br />
nipples, nuts, unions, quick shut off valves on main pipes<br />
and branch pipes, brass fittings adapter, automatic vents<br />
..Etc of approved quality. The price should also supplying<br />
and installing 16mm pexgol plastic pipes with its 25mm<br />
plastic conduits with 5cm thick concrete layer to radiator<br />
outlets, copper elbows recessed in walls and all civil works<br />
needed, all according to drawings and engineer’s<br />
instructions, and as follows:<br />
14.4.1 Collector 11/4" diameter (Unit is in collector openings) EYE 58<br />
14.5 supply and install metallic painted steel cabinets, size<br />
(80*60cm) of approved quality, including cover with double<br />
doors for heating collectors. The cabinets should be<br />
recessed in walls and fixed on wooden frame constructed<br />
in the wall.<br />
NO 3<br />
14.6 Supply only pressure tank of 125 liters capacity, type Reflex<br />
or E.A.<br />
Total of Central Heating System Works carried to<br />
Mechanical summary:<br />
NO 1<br />
12
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
15 VENTILATION SYSTEM<br />
15.1 Supply and install ducted outdoor centrifugal exhaust and<br />
fresh air fans, type Wood, S&P or EA. The price includes<br />
vibration isolators, metallic steel base, galvanized adapter,<br />
flexible connection, insect mesh at fan outlet of fan and all<br />
accessories needed for installation and commissioning.<br />
The price shall also include electrical and control cables<br />
and connections to main distribution board, all according to<br />
drawings and engineer’s instructions. The fan capacity is<br />
as follows:<br />
15.1.1 * 950 L/s Air Flow @ 0.8" Static pressure NO 1<br />
15.1.2 * 750 L/s Air Flow @ 0.8" Static pressure NO 1<br />
15.1.3 * 560 L/s Air Flow @ 0.5" Static pressure NO 1<br />
15.2 Supply and install ducted in-line exhaust fan, type Wood,<br />
S&P or EA. The price includes vibration isolators,<br />
galvanized adapter, flexible connection and all accessories<br />
needed for installation and commissioning. The price shall<br />
also include outdoor rain water gravity grilles with insect<br />
mesh and shutter according to the sizes shown on<br />
drawings, and also electrical and control cables and<br />
connections to main distribution board, all according to<br />
drawings and engineer’s instructions. The fans capacities<br />
are as follows:<br />
15.2.1 * 135 L/s Air Flow @ 0.2" Static pressure NO 2<br />
15.2.2 * 120 L/s Air Flow @ 0.2" Static pressure NO 1<br />
15.2.3 * 100 L/s Air Flow @ 0.2" Static pressure NO 1<br />
15.3 Supply, install and commission window and wall type<br />
exhaust air fan, type Wood, S&P or E.A, with automatic<br />
shutter. The price includes openings in walls or windows,<br />
electrical wirings and connections to main distribution board<br />
according to engineer’s instructions and as follows:<br />
15.3.1 · 25 L/s Air Flow NO 1<br />
15.3.2 · 40 L/s Air Flow (suitable for duct connection) NO 1<br />
15.3.3 · 60 L/s Air Flow NO 1<br />
15.3.4 · 75 L/s Air Flow NO 1<br />
15.3.5 · 100 L/s Air Flow NO 1<br />
15.4 Supply and install galvanized metal sheet duct, with<br />
thickness according to ASHRAE Standards, for exhaust<br />
and fresh air system. The price includes all joints, sealant<br />
compound, fire retardant sealant and all necessary<br />
accessories, dampers (where required), splitter dampers,<br />
galvanized hangers, and hooks.<br />
M2 150<br />
15.5 Supply and install white anodized Aluminum, of approved<br />
quality, exhaust and fresh air grilles, type Cooling Industry<br />
or E.A, with registers. The price includes galvanized<br />
adapter, opening in false ceiling or gypsum boards, and<br />
duct flexible connection of size as shown on the drawings.<br />
The sizes of grilles are as follows:<br />
15.5.1 * 60cm X 15cm NO 2<br />
15.5.2 * 55cm X 15cm NO 3<br />
15.5.3 * 45cm X 15cm NO 7<br />
15.5.4 * 35cm X 15cm NO 3<br />
15.5.5 * 23cm X 23cm NO 15<br />
15.5.6 * 15cm X 15cm NO 2<br />
15.6 Supply and install white anodized Aluminum, of approved<br />
quality, fresh air intake louvers, type Cooling Industry or<br />
E.A, with insect mesh and filter. The price includes<br />
galvanized adapter, opening in walls and connection to<br />
fresh air duct as shown on the drawings. The sizes of<br />
grilles are as follows:<br />
15.6.1 * 55cm X 35cm<br />
Total of Ventilation System Works carried to<br />
Mechanical summary:<br />
NO 2<br />
13
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
16 AIR CONDITIONING SYSTEM<br />
16.1 Supply, install and commission outdoor Variable<br />
Refrigerant Flow (VRF) heat pump air conditioning sets<br />
based on refrigerant R410, type Daikin, Toshiba or E.A,<br />
consisting of two units (2 X 20 kW) cooling capacity and (2<br />
X 22 kW) heating capacity. The price include control<br />
system, steel bases, gas pipes network from outdoor units<br />
till the indoor units located in the X-Ray department, in<br />
addition to headers and pipes branches and all accessories<br />
needed to complete the job. The price shall also include<br />
electrical wirings and connection to main distribution<br />
boards.<br />
16.2 Supply, install, and commission indoor VRF air conditioning<br />
units, type Daikin, Toshiba or E.A, decorative type,<br />
complete with remote control, drain pipes to floor drains,<br />
builders work, electrical wirings and connections to main<br />
distribution boards, all according to drawings,<br />
specifications, and approval of supervisor engineer:<br />
SET 1<br />
16.2.1 * 7 kW cooling Cap. & 330 L/s Air Flow NO 2<br />
16.2.2 * 5.2 kW cooling Cap. & 280 L/s Air Flow NO 3<br />
16.2.3 * 2.6 kW cooling Cap. & 150 L/s Air Flow NO 3<br />
16.3 Supply, install, and commission indoor VRF air conditioning<br />
units, type Daikin, Toshiba or E.A, ducted concealed type,<br />
complete with copper pipes connections, acoustic<br />
insulation adapter between the units and ducts, room<br />
thermostat, drain pan and connections to floor drains,<br />
supports and hangers, builders work, flexible connections,<br />
connections with supply and fresh air duct, electrical<br />
wirings and connections to main distribution boards, all<br />
according to drawings, specifications, and approval of<br />
supervisor engineer, as follows:<br />
16.3.1 * 14 kW cooling Cap. & 540 L/s Air Flow NO 2<br />
16.4 Supply, install, and commission ducted mini-central heat<br />
pumps split units, type Daikin, Toshiba or E.A. The price<br />
includes all accessories and fittings needed for installation<br />
and commissioning, flexible connections, connection of<br />
drain pipe, acoustic insulation adapter between the units<br />
and ducts, vibration isolators, hangers and supports, high<br />
performance washable filters, wall mounted thermostat<br />
(three fan speeds – summer/winter changeover –<br />
temperature setting module), drain pan, insulated copper<br />
pipes, metallic steel base for outdoor units and all electrical<br />
wiring and control cable, in addition to connection to MDB.<br />
Rate shall also include openings in walls through sleeves<br />
of good quality, and refilling works:<br />
16.4.1 10 kW Cooling Capacity & 380 L/s Air Flow NO 1<br />
16.5 Supply and install galvanized metal sheet rectangular duct,<br />
with thickness according to ASHRAE Standards, for air<br />
conditioning system. The price includes thermal external<br />
insulation (1" thick, 24kg/m 3 density), all joints, sealant<br />
compound, fire retardant sealant, dampers (where<br />
required), splitter dampers, galvanized hangers, and<br />
M2 50<br />
hooks.<br />
16.6 Supply and install white anodized Aluminum, of approved<br />
quality, 4-way supply air diffusers, type Cooling Industry<br />
E.A, with registers. The price includes galvanized adapter,<br />
opening in false ceiling or gypsum boards, and duct<br />
flexible connection of size as shown on the drawings. The<br />
sizes of grilles are as follows:<br />
16.6.1 * 30cm X 30cm NO 8<br />
14
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
16.7 Supply and install white anodized Aluminum, of approved<br />
quality, return air grilles, type Cooling Industry or E.A. The<br />
price includes opening in false ceiling or gypsum boards.<br />
The sizes of grilles are as follows:<br />
16.7.1 * 60cm X 60cm NO 1<br />
16.7.2 * 30cm X 30cm<br />
Total of Air Conditioning System Works carried to<br />
Mechanical summary:<br />
NO 1<br />
17 MEDICAL GAS SYSTEM<br />
17.1 Supply and install area valve control box for medical<br />
oxygen and vacuum, including 2-full port, 3 parts shut off<br />
valves which controls the supply of oxygen or vacuum<br />
through the pipe lines, and line pressure and vacuum<br />
gauges. The area valves control boxes should also include<br />
an emergency external supply port, equipped with disk and<br />
clutch mechanism for quick plug-in connection of the<br />
emergency external supply source.<br />
NO 1<br />
17.2 Supply and install local area pressure and vacuum alarm<br />
box; local audio-visual pressure alarm box for medical<br />
oxygen and vacuum to indicate pressure and vacuum<br />
failures by means of green LED, red LED, operated by<br />
means of one central PC card and switches, recessed type<br />
with anodized aluminum panel.<br />
17.3 Supply and install of factory preassembled bed head unit<br />
for two beds, according to CE-0473, EN-46001, ISO9001<br />
encompassing extruded aluminum duct system, with four<br />
cavities, three of which are directly accessed using snap-on<br />
covers. Supply electrical and lighting service, as well as<br />
medical gas service. The gas outlets should be installed in<br />
a separate compartment. The number of electrical circuits,<br />
apart of the low voltage circuit, should be two, main lines<br />
power circuit and lighting circuit, each connected to a<br />
separate terminal at the main special electrical connection<br />
compound in the bed-head unit.<br />
NO 1<br />
NO 11<br />
Two oxygen outlet<br />
Two vacuum outlet<br />
Four electrical sockets, main line<br />
Two potential grounding sockets<br />
Indirect Light<br />
Direct Light<br />
Cutt-off switch for direct-indirect lights<br />
Two telephone sockets<br />
preparation for nurse call sockets<br />
17.4 Ditto, but for one head-Bed Unit. NO 1<br />
17.5 Supply, install, test and commission connect to the served<br />
terminals, phosphorous de-oxidized non-arsenical copper<br />
(C106) to BS 1172 pipes complete with, such as, but not<br />
limited to, fittings, valves, supports, brackets, etc., taking<br />
into consideration of all safety prepotions that must be<br />
applied to avoid damage of pipes or contaminations. The<br />
price also include different gas ID marks & rubber ceiling<br />
between band & pipes, all according to drawings and<br />
engineer's instruction. The sizes of the pipes are as follows:<br />
17.5.1 1 1/8'' diameter (O.D) M.R 60<br />
17.5.2 7/8'' diameter (O.D) M.R 75<br />
17.5.3 5/8'' diameter (O.D) M.R 110<br />
17.5.4 3/8'' diameter (I.D) M.R 80<br />
Total of Medical Gas System Works carried to<br />
Mechanical summary:<br />
15
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
Section III - Electrical Works<br />
18 Lighting<br />
18.1 Light Point:-<br />
Supply, install, test and commission a complete indoor ,<br />
outdoor lighting point including all conductors, cables,<br />
conduits (PVC or galvanized), switches (type Legrand<br />
Mosaic Cross decorative plates range modular components<br />
and self-supporting plates or equal approved), boxes,<br />
ceiling rose, flexible connection and all other accessories,<br />
from appropriate distribution board to lighting point, as<br />
specified and detailed on drawings and the Engineer's<br />
instructions.<br />
18.2 Light Fixture:-<br />
Supply, install, test and commission complete lighting<br />
Fixtures, including all supports, lamps, connections,<br />
suspensions, clamps, capacitors, internal connections,<br />
conductors, bridges, trenching and all other accessories<br />
necessary to provide a complete fittings with all terminals<br />
according to specifications, drawings and the Engineer's<br />
instructions.<br />
18.2.1 TYPE A : 2X26w recessed low energy compact fluorescent<br />
cat2 louver type Thorn or equal approved.<br />
18.2.2 TYPE B : 2X26w recessed low energy compact fluorescent<br />
cat2 louver type Thorn or equal approved.<br />
18.2.3 TYPE C: 2X13w recessed low energy compact fluorescent<br />
with glass IP44 type Thorn or equal approved.<br />
18.2.4 As type A but with non-maintained 3HR conversion packs<br />
integrated into lighting fittings throughout, the batteries and<br />
inverter gear shall be self contained in the emergency<br />
lights. Batteries shall be sealed nickel cadmium or nickel<br />
meta-hydride type with life expectancy of 5 year min.<br />
18.2.5 As type B but with non-maintained 3HR conversion packs<br />
integrated into lighting fittings throughout, the batteries and<br />
inverter gear shall be self contained in the emergency<br />
lights. Batteries shall be sealed nickel cadmium or nickel<br />
meta-hydride type with life expectancy of 5 year min.<br />
18.2.6 As type C but with non-maintained 3HR conversion packs<br />
integrated into lighting fittings throughout, the batteries and<br />
inverter gear shall be self contained in the emergency<br />
lights. Batteries shall be sealed nickel cadmium or nickel<br />
meta-hydride type with life expectancy of 5 year min.<br />
NO 153<br />
NO 6<br />
NO 12<br />
NO 31<br />
NO 2<br />
NO 3<br />
NO 10<br />
18.2.7 TYPE D : 2X36W high frequency recessed light fixture with<br />
prismatic diffuser type Cooper or equal approved.<br />
NO 64<br />
18.2.8 As type D: but with non-maintained 3HR conversion packs<br />
integrated into lighting fittings throughout, the batteries and<br />
inverter gear shall be self contained in the emergency lights<br />
batteries shall be sealed nickel cadmium or nickel metahydride<br />
ty<br />
NO 15<br />
18.2.9 As type D: but with special lamp for dark room NO 4<br />
18.2.10 TYPE E: 1x8W Self contained, recessed ceiling mounted<br />
edge-lit double sided exit sign for maintained emergency<br />
lighting of 3 hour duration.<br />
NO 4<br />
18.2.11 TYPE F: 2x9 watt surface mounted luminary with opal<br />
diffuser type Thorn, RZB or equal approved.<br />
NO 4<br />
18.2.12 TYPE G : 2X36W Waterproof fluorescent with acrylic<br />
diffuser IP65 type Thorn or equal approved.<br />
Total of Lighting System works carried to Electrical<br />
summary:<br />
NO 2<br />
16
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
19 Power System Works<br />
19.1 Main Feeder:-<br />
Supply, install, test and commission 600/1000V XLPE<br />
copper cables including glands, cable ties, labeling, and all<br />
associated accessories according to the drawings,<br />
specifications and relevant codes of practice and highest<br />
prevailing engineering standards, for the following:<br />
19.1.1 3 X 150 + 70 mm 2 + 150 mm 2. M.R 35<br />
19.1.2 3 X 35 + 16 mm 2 + 35 mm 2. M.R 40<br />
19.1.3 5 X 25 mm 2. M.R 75<br />
19.1.4 5 X 10 mm 2 M.R 24<br />
19.1.5 5 X 6 mm 2 M.R 20<br />
19.2 Distribution Boards:<br />
Supply, install, test and commission complete main<br />
distribution board inclusive of all circuit breakers type<br />
Moeller or equal approved for outing and incoming cables,<br />
bus bars and their coupling unit, casing spaces for cables,<br />
cable clamps/terminals, cable shoes, protection equipment,<br />
as required to form a complete unit for. All shall be in<br />
accordance with the drawings, specification, the codes of<br />
practice and highest prevailing standards of engineering.<br />
19.2.1<br />
The Contractor shall submit detailed shop drawings for the<br />
board to take approval from the Engineer before<br />
manufacturing.<br />
DB-X-RAY NO 1<br />
19.2.2 DB-IMW NO 1<br />
19.3 Earthing System:-<br />
Supply, install, test and commission a complete ring<br />
grounding system for mechanical plants and all big metallic<br />
masses, etc., including all conductors, copper bars, clamps,<br />
conduits fixing etc., all in accordance with specifications,<br />
drawings and codes of practice.<br />
L.S 1<br />
19.4 Sub-Installation:<br />
Supply, install, test, number and commission a complete<br />
single phase single socket outlets, including all conductors,<br />
cables, conduits, boxes, sockets outlets (type Legrand<br />
Mosaic Cross decorative plates range modular components<br />
and self-supporting plates or equal approved), and all<br />
connections between the appropriate distribution board to<br />
the terminal point, as specified and as detailed on<br />
NO 66<br />
drawings:<br />
19.4.1 Supply, install, test and commission as per item 1, but 13A<br />
single phase double socket outlets.<br />
NO 4<br />
19.4.2 Supply, install, test and commission as per item 1, but 13A<br />
single phase water proof socket outlets.<br />
NO 15<br />
19.4.3 Supply, install, test and commission as per item 1, but 16A<br />
isolating switch for fan coil.<br />
NO 8<br />
19.4.4 Supply, install, test and commission as per item 1, but 16A<br />
3 phase isolating switch IP65.<br />
NO 1<br />
19.4.5 Supply, install, test and commission as per item 1, but 63A<br />
isolating switch IP65.<br />
NO 1<br />
19.4.6 Supply, install, test and commission as per item 1, but 16A<br />
single phase socket outlets for exhaust fan with indication<br />
lamp.<br />
NO 1<br />
19.4.7 Supply, install Modular flush floor service outlet box<br />
300x200x80mm, three compartments, including double<br />
socket outlet, RJ45 data socket outlet, RJ11 telephone<br />
socket outlet type Legrand or equal approved..<br />
NO 1<br />
19.4.8 Supply, install, test and commission a stainless steel hand<br />
dryer, automatic type, operated by photo cell, surface type,<br />
AC supply, 1500 W, 220V, 50Hz, Including cables,<br />
conduits, boxes and all other accessories from appropriate<br />
distribution board to the hand dryer as specified and<br />
detailed on drawings.<br />
NO 4<br />
17
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
19.4.9 Supply, install, test and commission hot deep galvanized<br />
steel perforated cable tray, complete with all mounting<br />
accessories, tees, reducers, covers, elbows, etc. as shown<br />
on the drawings and specification for the following:<br />
19.4.10 30cm wide M.R 72<br />
19.5 Bed Head Unit<br />
Supply, install, test and commission a complete electrical<br />
point for units including conductors, conduits, accessories,<br />
boxes, wiring interconnections, earthing, etc., for complete<br />
workable unit. Point consist of lighting point, power<br />
receptacles points, telephone point, nurse call point, as<br />
specified and as detailed on drawings.<br />
NO 12<br />
Total of Power System works carried to Electrical<br />
summary:<br />
20 Telephone & Computer Networks Systems<br />
20.1 Telephone System:<br />
20.1.1 Supply, install, test and commission complete telephone<br />
point including all conduits, boxes (flush or surface<br />
mounted), cabling (Cat5e 4 pair unscreened) type Teldor,<br />
RG 45 Cat5e outlet type Legrand or equal approved.<br />
According to specifications, and drawings. All Telephone<br />
outlets shall be numbered in sequence.<br />
20.1.2 Supply, install, test and commission telephone terminal<br />
boards (TTB) complete with all accessories needed for<br />
complete work, incoming cables, as specified and as<br />
detailed on drawings for the followings:<br />
NO 6<br />
a 30 pairs L.S 1<br />
b 20 pairs L.S 1<br />
20.2 Computer Networks Systems:<br />
20.2.1 Supply, install, connect and commission complete data<br />
point including all conduits, boxes (flush or surface<br />
mounted), cables STP cat6 type Teldor, RG 45 Cat 6 outlet<br />
type 3M or equal approved. According to specification and<br />
drawings. All Data outlets shall be numbered in sequence.<br />
NO 5<br />
20.2.2 Supply, install, test, and commissioning Data Panel(DP)<br />
18U including 1 air patch panels,1 patch panels type 3M,<br />
power strip all needed internal cables, connections and all<br />
accessories to complete the work. as specified and as<br />
detailed on drawings, and to the Engineer's instructions.<br />
20.2.3 Supply, install, test and commission complete satellite point<br />
including all conduits, cable, conduit accessories, boxes<br />
outlet type Legrand or equal approved. According to<br />
specifications, and drawings. All outlets shall be numbered<br />
in sequence.<br />
20.2.4 Supply, install, test and commission hot deep galvanized<br />
steel perforated cable tray, complete with all mounting<br />
accessories, tees, reducers, covers, elbows, etc. as shown<br />
on the drawings and specification for the following:<br />
20cm wide.<br />
Total of Telephone & Computer Networks Systems<br />
works carried to Electrical summary:<br />
18<br />
L.S 1<br />
NO 8<br />
M.R 42
ATLAS # 14163<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Item DESCRIPTION Unit QTY Unit Price Total Amount<br />
21 Fire Alarm System<br />
21.1 Supply, install, test and commission new fire alarm loop,<br />
this loop shall be connected to existing FACP (the existing<br />
fire alarm panel Type Edward) including commission FACP,<br />
all conduits, boxes, cabling type Teldor, According to<br />
specifications.<br />
21.2 Supply, install, test and commission a fire alarm photooptical<br />
smoke detector including all conduits fixing, boxes,<br />
and cables (type Teldor or equal approved), . According to<br />
specification and drawings. Type Edward<br />
21.3 Supply, install, test and commission a fire-alarm heatdetector<br />
including all conduits fixing, boxes, and cables.<br />
According to specification and drawings.<br />
21.4 Supply, install, test and commission a fire alarm electronic<br />
sounder Banshee type including all conduits fixing, boxes,<br />
and cables. According to specification and drawings.<br />
21.5 Supply, install, test and commission a flush mounted fire<br />
alarm manual pull station including all conduits fixing,<br />
boxes, and cables. According to specification and<br />
drawings.<br />
Total of Fire Alarm System works carried to Electrical<br />
summary:<br />
22 Nurse Call System:<br />
22.1 Supply, install, test and commission 50 call master station<br />
nurse call including conduits, conduit accessories, boxes,<br />
cabling, etc., all in accordance with drawings and<br />
specifications and engineer instructions type Aiphone or<br />
equal approved<br />
22.2 Supply, install, test and commission central control unit<br />
including power supply, conduits, conduit accessories,<br />
boxes, cabling, etc., all in accordance with drawings and<br />
specifications and engineer instructions type Aiphone or<br />
equal approved.<br />
22.3 Supply, install, test and commission wall mounted single<br />
jack including conductors, and/or cables, conduits, boxes,<br />
etc., from the appropriate nurse call panel to the point the<br />
price includes also beside call switch in accordance with<br />
the specifications and drawings.<br />
22.4 Supply, install, test and commission as per item 1, but dual<br />
jack.<br />
22.5 Supply, install, test and commission as per item 1, but<br />
corridor lamp with red lamp<br />
22.6 Supply, install, test and commission as per item 1, but Zone<br />
lamp<br />
22.7 Supply, install, test and commission as per item 1, but<br />
emergency bathroom pull cord.<br />
Total of Nurse Call System works carried to Electrical<br />
summary:<br />
23 Public Address System<br />
23.1 Connect, test and commission the new loudspeaker to<br />
existing system including all conduits, boxes, cabling ,<br />
According to specifications and engineer instructions<br />
23.2 Supply, install, test and commission the 6 watt flush-mount<br />
ceiling loudspeaker with matching transformer.<br />
Total of Public Address System works carried to<br />
Electrical summary:<br />
19<br />
L.S 1<br />
NO 32<br />
NO 2<br />
NO 3<br />
NO 3<br />
L.S 1<br />
L.S 1<br />
NO 1<br />
NO 11<br />
NO 9<br />
NO 1<br />
NO 2<br />
L.S 1<br />
NO 6
ATLAS # 14163 Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
Bill Description Total<br />
Section I Civil Works Summary<br />
1 Demolish and Removal Works<br />
2 Block work<br />
3 Plastering Works<br />
4 Tile Finishing Works<br />
5 False Ceiling Works<br />
6 Painting Works<br />
7 Carpentary & Joinery Works<br />
8 Insulatuion Works<br />
9 Glass Works<br />
10 Metal Works<br />
11 Sand-blasting Works<br />
Total of Civil Works<br />
Section II Mechanical Works Summary<br />
12 Sanitary fixture and their Accessories:<br />
13 Water & Fire Fighting Works<br />
14 Central Heating Works<br />
15 Ventalation Works<br />
16 Air Conditioning Works:<br />
17 Medical Gas Supply:<br />
Total of Mechanical Works<br />
Section III Electrical Works Summary<br />
18 Lighting System Works<br />
19 Power System Works<br />
20 Telephone & IT System<br />
21 Fire Alarm System<br />
22 Nurse Calling System<br />
23 Public Address System<br />
Total of Electrical Works<br />
NET TOTAL SUM (in words ) :<br />
SIGNED AND SEALED :<br />
AUTHOURIZED PERSON :<br />
TITLE :<br />
SIGNATURE :<br />
DATE :<br />
Summary of Part 2<br />
Total of Part 2 (Excluding VAT)<br />
Discount %<br />
Discount Amount<br />
Net Total - Part 2 (Excluding VAT)
ATLAS # 14163 <strong>Alia</strong> Hospital<br />
Item Description Total<br />
Bill 1<br />
Bill 2<br />
Part 1: Construction of the remaining works at <strong>Alia</strong> Hospital 2nd floor<br />
Part 2: Rehabilitation Works For <strong>Alia</strong> Hospital<br />
NET TOTAL SUM (in words ) :<br />
SIGNED AND SEALED :<br />
AUTHOURIZED PERSON :<br />
TITLE :<br />
SIGNATURE :<br />
DATE :<br />
Grand Summary (Part 1 + Part 2)<br />
Grand Total Part 1 & Part 2 (Excluding VAT)<br />
Discount %<br />
Discount Amount<br />
Net Total Part 1 & Part 2 (Excluding VAT)