Fibre optic cables - Draka
Fibre optic cables - Draka
Fibre optic cables - Draka
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Finnish type designation<br />
for <strong>optic</strong>al fibre <strong>cables</strong><br />
Type designation example:<br />
Cable design<br />
<strong>Fibre</strong> count and grouping<br />
<strong>Fibre</strong>s and coatings<br />
FYOVD2PMU 4 x 6 x SML<br />
Cable design <strong>Fibre</strong>s<br />
First letter:<br />
F = <strong>optic</strong>al fibre cable<br />
Second letter:<br />
Y = central tube design (e.g. SPIRAL SPACE ® )<br />
Z = stranded loose tube design<br />
T = tight buffer design<br />
X = slotted core design<br />
Next letters:<br />
B = laminated O = filling compound<br />
C = copper P = steel wire<br />
D = corrugated R = non-metallic strength element<br />
H = aluminium tape<br />
J = jute V = steel tape<br />
K = messenger wire S = indoor<br />
L = lead U = outdoor<br />
M = plastic W = underwater<br />
-Y = cable contains more than one type of fibre<br />
-SD = semi-dry construction<br />
E.g. FYOVD2PMU<br />
(<strong>optic</strong>al fibre cable, central tube, filled, corrugated steel tape,<br />
2 steel wires, plastic sheath, outdoor)<br />
<strong>Fibre</strong> count and grouping:<br />
Numbers after cable design indicate number of fibre units<br />
(tubes or groups) and number of fibres in the unit.<br />
Alternatively only the total number of fibres can be indicated.<br />
E.g. 4x6 (four units of six fibres)<br />
<strong>Fibre</strong>s and fibre coatings:<br />
First two characters in fibre designation indicates fibre type,<br />
the third character indicates the outer diameter of fibre coating,<br />
followed by reference to standard:<br />
SM G.652.B = Single-mode fibre (10/125 mm)<br />
ITU-T (G.652.B)<br />
SM G.652.D = Y= Single-mode fibre (10/125 mm)<br />
ITU-T (G.652.D)<br />
SM BBXS = Single-mode fibre (10/125 mm)<br />
ITU-T (G.652.D, G.657.A, G.657.B),<br />
Bend-insensitive BendBright XS fibre<br />
Gl OM2 = = Multimode fibre (50/125 mm)<br />
ITU-T (G.651)<br />
Gl OM3 = Multimode fibre (50/125 mm) (OM3)<br />
GK OM1 = Multimode fibre (62.5/125 mm) (OM1)<br />
L = 250 mm T = 900 mm<br />
R = <strong>Fibre</strong> ribbon<br />
E.g SML G652.D<br />
(Single-mode fibre ITU-T G.652.D, coating diameter 250 mm)<br />
58 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 59<br />
Further details