11.01.2013 Views

CAMLOG Vario SR Prosthetic Components

CAMLOG Vario SR Prosthetic Components

CAMLOG Vario SR Prosthetic Components

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Vario</strong> <strong>SR</strong> <strong>Prosthetic</strong>s<br />

SIMPLY PERFECTED<br />

NEW PROSTHETIC SCREW CONNECTION FOR<br />

STRAIGHT <strong>CAMLOG</strong> ® VARIO <strong>SR</strong> ABUTMENTS<br />

Straight <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are fixed in the implant using the<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw. The <strong>Vario</strong> <strong>SR</strong> caps are secured<br />

using the <strong>Vario</strong> <strong>SR</strong> prosthetic screw when inserting the superstructure.<br />

The prosthetic screw engages in the thread in the head of the <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutment screw and fixes the cap to the abutment.<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment,<br />

straight<br />

NEW 20° AND 30° ALIGNING TOOLS FOR BETTER HANDLING<br />

AND MORE TIME SAVINGS<br />

If you are placing several implants, the <strong>Vario</strong> <strong>SR</strong> 20° and 30° aligning tools<br />

can be used to check the respective insertion direction and alignment of the<br />

implant grooves before inserting the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />

Just put the respective aligning tool over the insertion post attached to the<br />

<strong>CAMLOG</strong> ® implant. If necessary, you can slightly adjust the alignment of<br />

the grooves of the inner implant configuration.<br />

The angulation of the <strong>Vario</strong> <strong>SR</strong> aligning tools is identical to the 20° and 30°<br />

angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />

Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 20° and<br />

<strong>Vario</strong> <strong>SR</strong> aligning tool<br />

<strong>Vario</strong> <strong>SR</strong><br />

plastic coping<br />

<strong>Vario</strong> <strong>SR</strong><br />

prosthetic screw<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />

abutment<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />

abutment screw<br />

Insertion post<br />

Implant<br />

2 chamfer = 20° 3 chamfer = 30°<br />

Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 30° and<br />

<strong>Vario</strong> <strong>SR</strong> aligning tool<br />

<strong>Vario</strong> <strong>SR</strong> aligning tool<br />

The angulation points in the opposite direction<br />

of the <strong>CAMLOG</strong> ® implant groove.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!