CAMLOG Vario SR Prosthetic Components
CAMLOG Vario SR Prosthetic Components
CAMLOG Vario SR Prosthetic Components
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Vario</strong> <strong>SR</strong> <strong>Prosthetic</strong>s<br />
SIMPLY PERFECTED<br />
NEW PROSTHETIC SCREW CONNECTION FOR<br />
STRAIGHT <strong>CAMLOG</strong> ® VARIO <strong>SR</strong> ABUTMENTS<br />
Straight <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are fixed in the implant using the<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw. The <strong>Vario</strong> <strong>SR</strong> caps are secured<br />
using the <strong>Vario</strong> <strong>SR</strong> prosthetic screw when inserting the superstructure.<br />
The prosthetic screw engages in the thread in the head of the <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutment screw and fixes the cap to the abutment.<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment,<br />
straight<br />
NEW 20° AND 30° ALIGNING TOOLS FOR BETTER HANDLING<br />
AND MORE TIME SAVINGS<br />
If you are placing several implants, the <strong>Vario</strong> <strong>SR</strong> 20° and 30° aligning tools<br />
can be used to check the respective insertion direction and alignment of the<br />
implant grooves before inserting the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />
Just put the respective aligning tool over the insertion post attached to the<br />
<strong>CAMLOG</strong> ® implant. If necessary, you can slightly adjust the alignment of<br />
the grooves of the inner implant configuration.<br />
The angulation of the <strong>Vario</strong> <strong>SR</strong> aligning tools is identical to the 20° and 30°<br />
angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />
Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 20° and<br />
<strong>Vario</strong> <strong>SR</strong> aligning tool<br />
<strong>Vario</strong> <strong>SR</strong><br />
plastic coping<br />
<strong>Vario</strong> <strong>SR</strong><br />
prosthetic screw<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />
abutment<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />
abutment screw<br />
Insertion post<br />
Implant<br />
2 chamfer = 20° 3 chamfer = 30°<br />
Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 30° and<br />
<strong>Vario</strong> <strong>SR</strong> aligning tool<br />
<strong>Vario</strong> <strong>SR</strong> aligning tool<br />
The angulation points in the opposite direction<br />
of the <strong>CAMLOG</strong> ® implant groove.