10.7. All coating inspection instruments, inspection standards, calibration standards, and testing<br />
materials shall be in good working order, appropriate for the use intended, and where required,<br />
shall have been calibrated within twelve (12) months of their use. The owner shall have access to<br />
all required calibration certificates.<br />
10.8. Coating dry film thickness shall be determined by the use of magnetic thickness instruments used<br />
and calibrated in accordance with SSPC, Paint Application Standard PA2.<br />
10.9. Coating areas that fail to meet the minimum dry film thickness requirements of the SSPC-PA2<br />
survey method shall be repaired in accordance with the guidelines presented in Section 9.0.<br />
Page 9 of 9<br />
04/10 Irathane 155 Steel