Pole Pole Changing Changing Changing Starters<br />

Starters<br />

Data Data according according to to to IEC IEC 947-4-1, 947-4-1, VDE VDE 0660, 0660, 0660, EN EN 60947-4-1 60947-4-1<br />

60947-4-1<br />

Type Type<br />

K3PU18 K3PU18 K3PU24 K3PU24 K3PU24 K3PU32 K3PU32 K3PU32 K3PU50 K3PU50 K3PU62<br />

K3PU62<br />

Main Main Contacts<br />

Contacts<br />

1) Rated Rated insulation insulation voltage voltage voltage U Ui<br />

V AC 690 690 690 690 690<br />

Utilization Utilization category category AC3<br />

AC3<br />

Switching Switching of of three-phase three-phase motors<br />

motors<br />

Rated operational current Ie 220V<br />

230V<br />

A<br />

A<br />

18<br />

17,5<br />

23<br />

23<br />

30<br />

30<br />

45<br />

45<br />

63<br />

60<br />

240V A 17 23 30 45 60<br />

380-400V 380-400V A 16 16 23 23 30 30 45 45 60<br />

60<br />

415V A 16 23 30 45 60<br />

440V A 16 23 30 45 60<br />

500V A 16 23 30 45 55<br />

660V A 9 17,5 21 33 42<br />

690V A 8,5 17 20 31 40<br />

Rated operational power 220-230V kW 5 6 8,5 12,5 18,5<br />

of three-phase motors 240V kW 5 7 9 13,5 19<br />

50-60Hz 380-400V 380-400V kW kW 7,5 7,5 7,5 11 11 15 15 22 22 30<br />

30<br />

415-440V kW 8,5 12 16 24 33<br />

500V kW 10 15 18,5 30 37<br />

660-690V kW 7,5 15 18,5 30 37<br />

Cable Cable Cable cross-sections<br />

cross-sections<br />

Line solid or stranded mm² 0,75 - 6 1,5 - 25 4 - 50<br />

flexible mm² 1 - 4 2,5 - 16 6 - 35<br />

flexible with multicore cable end mm² 0,75 - 4 1,5 - 16 6 - 35<br />

cables per clamp 1 1 1<br />

Power Power consumption consumption of of of the the combination<br />

combination<br />

inrush and change-over VA 55 128 178<br />

sealed VA 20 26 31<br />

W 6 8 11<br />

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.<br />