Communications<br />

Data is communicated from site by;<br />

[31]<br />

• site interrogation via a laptop or palmtop (e.g. Psion) computer<br />

• return of the data logger to the office for PC interrogation<br />

• telemetry, either via PSTN, GSM or Paknet<br />

Telemetry data logger<br />

Telemetry loggers should be capable of linking to a range of communication systems. In<br />

addition to the data capture specifications listed in 3.3.2, they should have the option of;<br />

• internal PSTN modem<br />

• GSM (Cellnet or Vodaphone) module<br />

• Paknet radio-pad<br />

An initiative by one <strong>water</strong> company (reported in "Water Bulletin" - January 1998), involves<br />

connection via Vodaphone's wireless data network, using 1200 "Paknet Radio-Pad"<br />

connections (modem equivalent). It is claimed that purchase <strong>and</strong> installation of the radio<br />

network will cost 10% of a fixed line system, which can cost up to £3000.00 for a single<br />

connection. Line rental is also less (50% of a st<strong>and</strong>ard telecom line). The monitoring system<br />

uses ABB Kent-Taylor meters <strong>and</strong> a mix of Radcom <strong>and</strong> ABB data loggers. The antennae are<br />

housed in polyethylene pillars.<br />

Individual manufacturers can provide more detailed specifications for their monitoring<br />

equipment. Leading manufacturers are listed in Appendix 1.<br />

Monitoring software <strong>and</strong> information systems<br />

Software is required to arrange logged data into a form where it can be used for analysing <strong>and</strong><br />

interpreting total night flow losses in each DMA.<br />

Software for calculating <strong>and</strong> displaying total night flow losses is usually provided by logger<br />

manufacturers. Companies either use manufacturers' software, commission consultants, or use<br />

their own in-house facilities for writing software for leakage reports <strong>and</strong> for DMA management.<br />

Typical information required for these reports are;<br />

• DMA details<br />

• DMA night flow data <strong>and</strong> aggregated flows<br />

• total night flow losses in each DMA<br />