04.02.2013 Views

Bedienungsanleitung, Manuel, Manual, Manuale, 9116, PR - MTS ...

Bedienungsanleitung, Manuel, Manual, Manuale, 9116, PR - MTS ...

Bedienungsanleitung, Manuel, Manual, Manuale, 9116, PR - MTS ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3 100.0<br />

DISP.HI<br />

Txt 14<br />

3<br />

999.9<br />

-199.9<br />

1 2<br />

DISP<br />

PERC<br />

1 2<br />

3 DISP<br />

REL.UNI<br />

Txt 15<br />

3 @C<br />

3<br />

safety <strong>Manual</strong> <strong>9116</strong> UNiVeRsal coNVeRteR<br />

@C<br />

@F<br />

1 2<br />

UNIT<br />

Txt 9<br />

3<br />

ROutInG DIaGRam<br />

if no key is activated for 1 minute, the display will return to the default<br />

state 1.0 without saving configuration changes.<br />

1 increase value / choose next parameter<br />

2 Decrease value / choose previous parameter<br />

3 accept the chosen value and proceed to the next menu<br />

Hold 3 Back to previous menu / return to menu 1.0 without saving<br />

3<br />

continued on the next page<br />

1.0 = Default state. line 1 shows<br />

input status. line 2<br />

toggels between process<br />

value and UNit. line 3<br />

shows output and taG No.<br />

line 4 shows status for<br />

relay and communication<br />

and whether the device is<br />

sil-locked. static dot =<br />

sil-locked and flashing<br />

dot = not sil-locked.<br />

1.1 = only if password-protected.<br />

1.2 = only if Fastset is activated<br />

and the relay function is<br />

setpoint.<br />

selectable UNITS:<br />

@C<br />

@F<br />

K<br />

%<br />

m<br />

cm<br />

mm<br />

um<br />

ft<br />

in<br />

mils<br />

yd<br />

m3<br />

l<br />

s<br />

min<br />

m/s<br />

mm/s<br />

m/min<br />

m/h<br />

in/s<br />

ips<br />

ft/s<br />

in/min<br />

ft/min<br />

in/h<br />

ft/h<br />

m/s2<br />

rpm<br />

Hz<br />

24 Version No. V1R0<br />

1.3 = only if input types support<br />

sensor error check.<br />

Not valid for these input<br />

signals: 0...20 ma and<br />

voltage.<br />

1.4 = only if input signal is<br />

temperaure.<br />

1.5 = only if the configuration is<br />

not protected by a password.<br />

t<br />

kg<br />

g<br />

N<br />

Pa<br />

MPa<br />

kPa<br />

hPa<br />

bar<br />

mbar<br />

kj<br />

Wh<br />

MWh<br />

kWh<br />

W<br />

GW<br />

MW<br />

kW<br />

hp<br />

A<br />

kA<br />

mA<br />

uA<br />

V<br />

kV<br />

mV<br />

ohm<br />

S<br />

uS<br />

m3/min<br />

m3/h<br />

l/s<br />

l/min<br />

l/h<br />

gal/min<br />

gal/h<br />

t/h<br />

mol<br />

pH<br />

[blank]