The Menu System<br />
Performing Self Tests (SELF)<br />
The following self tests are available:<br />
Parameter Self-Test Description<br />
PAN Moves through the entire pan range<br />
TILT Moves through the entire tilt range<br />
DIM Tests LED Dimming function<br />
COLR Static color wheel function<br />
LT1 Rotating Gobo wheel movement<br />
LT1R Rotating Gobo wheel: rotating gobo movement<br />
LT2 Static Gobo wheel movement<br />
IRIS Tests Iris function<br />
FCUS Moves through the Focus range<br />
To start a self test process:<br />
1. Press and hold until AddR appears on the LED display.<br />
2. Scroll to the TEST menu. Press to select.<br />
3. Scroll to the SELF menu. Press to select.<br />
4. Scroll to the desired option (listed above).<br />
5. Press to start the test. The fixture will perform the selected self test.<br />
6. Press to exit the test.<br />
Moving the Fixture to Setup Position (S/UP)<br />
Caution: The setup position is used only by qualified service<br />
personnel during maintenance.<br />
To place the fixture in setup position before servicing:<br />
1. Hold until the display changes to AddR.<br />
2. Using the up and down buttons, scroll to the TEST field and press .<br />
3. Using the up and down buttons, scroll to the S/UP field and press . The display will<br />
indicate SET NOW while the motors are electronically locked into place.<br />
4. Perform the appropriate maintenance procedures.<br />
5. Press to reset and home the fixture.<br />