13.07.2015 Views

CENTRALES NUCLEARES NUCLEAR POWER PLANTS

CENTRALES NUCLEARES NUCLEAR POWER PLANTS

CENTRALES NUCLEARES NUCLEAR POWER PLANTS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ENERGÍA ELÉCTRICA BRUTA PRODUCIDA EN 1995GROSS ELECTRICAL ENERGY PRODUCED IN 1995GwhFACTOR DE CARGA DURANTE 1995CAPACITY FACTOR DURING 19951500100EDGY120090060030001360,21048,29686,02 1OR11127,71366,651316,581111,81061,09765,289R21360,471323,751370,1%)80604020098,2983,8749,641OR184,21ENE.98,76FEB.98,31MAR.80,34ABR.MAYJUNJUL.AGO.SEP.OCT.NOV.DIC.ENE.FEB.MAR.ABR.MAYJUN76,6857,07JUL.AGO.SEP.OCT.NOV.DIC.9R298,3198,8599,01horas del día 25 de abril, acoplándosea la red a las 8,31 horas.- El 21 de julio, a las 2,16 horas,desde una potencia de 452 MWe,cuando se continuaba con la subidade carga tras la resolución de incidentesacaecidos en el parque de 400 Kv,se produjo la parada de reactor, porseñal de parada automática de turbina,originado por la avería de un transformadorde intensidad del parque de400 Kv.Durante la parada se procedió a lasustitución de los transformadores deintensidad de salida de grupo, haciéndosecrítico el reactor a las 12,30 horasdel día 23, y acoplándose laUnidad a la red a las 10,42 horas deldía 24, permaneciendo de este mododurante el resto del período.INCIDENCIAS 1995. UNIDAD II- Debido a la necesidad de quitartensión, para sustituir los transformadoresde intensidad de salida de grupodel parque de 400 Kv, y garantizar laseguridad de los trabajos en el citadoparque, a las 13,45 horas del día 21de julio, se procedió a la reducción decarga hasta su desacoplamiento, manteniendoel reactor crítico. Tras la sustituciónde los trafos, la Unidad se acoplónuevamente a la red a las 12,08horas del día 23.- El 27 de julio, a las 11,53 horas, seprodujo la parada automática de laUnidad, por señal de alta velocidad devariación negativa de flujo neutrónico,como consecuencia de un transitoriooriginado por el disparo de la barra B-1 del parque de 400 Kv, que ocasionóla parada automática del reactor. A las18,36 horas del mismo día se hizonuevamente crítico el reactor, procediéndosea acoplar la Unidad a la reda las 20,39 horas.- El 19 de agosto, a las 2,44 horas,desde una potencia del 65%, se originóparada automática del reactor pormuy bajo nivel en el generador de vapor3, debido al cierre de las válvulasde agua de alimentación a los generadoresde vapor.Reparada la anomalía, el reactor se hizocrítico a las 7,08 horas, acoplándosela Unidad a la red a las 9,27 horas.SIMULACRO DE EMERGENCIA- El 10 de mayo se realizó el simulacroanual de emergencia, con la activaciónde todas las organizacionesimplicadas, comprobándose la coordinaciónde las mismas, así como lasvías de comunicación establecidaspara estos sucesos, calificándose dichosimulacro como satisfactorio.SIMULACRO DE PROTECCIÓNCONTRA INCENDIOS- El 29 de noviembre se realizó, conresultado satisfactorio, el simulacroanual de incendio.RESIDUOS RADIACTIVOS- Los residuos sólidos de baja actividadgenerados durante 1995 fueronun total de 781 bidones de 220 litros.- Durante el año han sido enviadasa las instalaciones de Enresa, enSierra Albarrana, diversas expedicionesde residuos sólidos de baja actividad,las cuales suponen un total de1.831 bidones de 220 litros.- La ocupación del almacén temporalde dichos residuos, al finalizar elperíodo es del 53,45%.OTROS- Obtención del Certificado deCalidad AENOR, entregado a CN.Almaraz el 28 de junio.- Implantación del Plan de Gestión yMejora continua de la Calidad.- Intercambio técnico entre represen-• Main condenser tube bundle replacement.• In the turboset, control valves and turbine shutdownwere checked and inspected.• As for primary circuit cooling pumps, the motor ofRCP-1 was removed and replaced by the standy, andthe seals of RCP-1 and RCP-2 were inspected.• The containment building penetrations wereinspected.• Just as in Unit I, several design modifications wereemade to optimize plant operation and tailor it to thesector’s latest technological advances.1995 INCIDENTS. UNIT I- On 2 February, an automatic reactor shutdownoccurred in this Unit, caused by automatic turbineshutdown due to actuation of main alternatorprotections. This was a result of actuation of the maintransformer’s protection due to failure of a transformer inthe 400 Kv yard.- On 1 April, when the nuclear tests at 0% power wereunderway, prior to connection after completion of theactivities programmed for the refueling outage, anautomatic reactor shutdown occurred as a result ofautomatic turbine shutdown due to involuntary actuationof PS-446A. Once the cause was identified, the reactorwas again made critical at 9:40 hours and the nucleartests were resumed.- At 11:33 hours on 3 Abril during stepped uploadafter the refueling outage, a reactor shutdown occurreddue to automatic turbine shutdown as a result of thelow condenser vacuum. Once the anomaly wasdetected, the reactor was again made critical at 14:50hours on the same day and the Unit went on line at23:09 hours.- On 22 April at 3:55 hours, due to detection of intakeof cooling reservoir water into the main condenser,which caused an alteration in secondary circuit chemicalparameters, a Unit download was begun and it wasdisconnected from the grid at 7:50 hours. When thecause of this water intake was investigated and theappropriate checks made, Unit heatup was begun, thereactor became critical at 4:25 hours on 25 April and theUnit went on line at 8:31 hours.- On 21 July at 2:16 hours, when upload was stillunderway after resolving incidents that occurred in the400 Kv yard, a reactor shutdown occurred from a powerof 452 MWe due to an automatic turbine shutdownsignal caused by failure of an intensity transformer of the400 Kv yard. During the shutdown, the unit outputintensity transformers were replaced, after which thereactor became critical at 12:30 hours on the 23rd andthe Unit went on line at 10:42 on the 24th. It stayed inthis mode for the rest of the year.1995 INCIDENTS.UNIT II- In view of the need to eliminate voltage in order toreplace the unit output intensity transformers of the 400Kv yard and to guarantee safety in the jobs to beperformed in this yard, at 13:45 hours on 21 July loadwas reduced until the Unit was disconnected,maintaining the reactor critical. After trafo replacement,the Unit again went on line at 12:08 hours on the 23rd.- On 27 July at 11:53 hours, an automatic Unit

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!