CoSFB - Nouvelle génération de poutrelles Slim-Floor<br />

CoSFB - New generation of slim-floor beams<br />

CoSFB - Neue Generation von Slim-Floor Trägern<br />

CoSFB (= Composite SFB)<br />

C<strong>et</strong>te poutrelle allie de façon<br />

innovante les avantages du<br />

système slim-floor avec ceux<br />

de la construction mixte; à<br />

savoir robustesse, longévité,<br />

résistance ductile, gr<strong>and</strong>e portée<br />

<strong>et</strong> tenue à l’incendie intégrée.<br />

En construction mixte classique,<br />

la dalle de béton est connectée<br />

à la poutrelle en acier via des<br />

goujons soudée sur la semelle<br />

supérieure. Dans le cas du CoSFB,<br />

la connexion s’effectue par<br />

des aciers d’armatures passant<br />

à travers le profilé par des<br />

ouvertures situées dans la partie<br />

supérieure de l’âme. La rigidité<br />

ainsi obtenue est rendue maximale<br />

sans avoir à augmenter la hauteur<br />

du plancher. Ce système autorise<br />

d’atteindre des portées de 14<br />

mètres avec un espacement entre<br />

solives de 10 mètres pour une<br />

épaisseur totale de plancher de<br />

40 cm seulement! Et ceci avec<br />

une trés faible consommation<br />

moyenne d’acier de 25 kg/m 2 , une<br />

excellente tenue au feu intégrée<br />

(jusqu’à R90) <strong>et</strong> une diminution<br />

de jusqu'à 40 % de l'empreinte<br />

carbone.<br />

CoSFB (= Composite SFB)<br />

CoSFB combines the advantages<br />

of slim-floor <strong>and</strong> composite<br />

construction (robustness,<br />

durability, ductile behavior, large<br />

spans, integrated fire resistance).<br />

A CoSFB is designed by replacing<br />

the traditional shear studs with<br />

reinforcement bars, placed<br />

through drilled holes in the<br />

web of the hot rolled section.<br />

Thanks to this innovative <strong>and</strong><br />

efficient connection the stiffness<br />

of the complex is significantly<br />

increased without modifying the<br />

construction thickness (slab +<br />

beam).<br />

For a beam distance of 10m <strong>and</strong><br />

a slab thickness of 40cm, beam<br />

spans up to 14m can are possible!<br />

The steel consumption of CoSFB<br />

is typically around +/- 25kg/<br />

m 2 , including a integrated fire<br />

resistance (up to R90) <strong>and</strong> up to<br />

40% reduced carbon footprint.<br />

CoSFB (= Composite SFB)<br />

Dieser Träger kombiniert auf<br />

innovative Weise die Vorteile<br />

der Slim-Floor Bauweise<br />

mit denen des Verbundbaus<br />

(Robustheit, Dauer-haftigkeit,<br />

duktiles Tragverhalten, große<br />

Spannweiten, integrierter<br />

Feuerwiderst<strong>and</strong>). Im klassischen<br />

Verbundbau wird die Verbindung<br />

zwischen Stahlprofil und Ortb<strong>et</strong>on<br />

durch auf den Obergurt aufgeschweißte<br />

Kopfbolzendübel<br />

erzielt. Beim CoSFB jedoch wird<br />

die Verbundtragwirkung über<br />

durch den Trägersteg geführte<br />

Bewehrungsstäbe sichergestellt.<br />

So wird die Steifigkeit maximiert,<br />

ohne die Konstruktionshöhe zu<br />

vergrößern. Mit dieser Bauweise<br />

können Spannweiten bis zu 14m<br />

mit einem Trägerabst<strong>and</strong> von<br />

10m und einer Deckenstärke von<br />

lediglich 40cm realisiert werden!<br />

Dies bei einem durchschnittlichen<br />

Stahlverbrauch von lediglich<br />

25kg/m 2 und integriertem<br />

Br<strong>and</strong>schutz (bis zu R90) und bis<br />

zu 40% weniger CO 2-Verbrauch.<br />

25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!