Profilés et Aciers Marchands Sections and Merchant Bars ... - Infosteel
Profilés et Aciers Marchands Sections and Merchant Bars ... - Infosteel
Profilés et Aciers Marchands Sections and Merchant Bars ... - Infosteel
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
CoSFB - Nouvelle génération de poutrelles Slim-Floor<br />
CoSFB - New generation of slim-floor beams<br />
CoSFB - Neue Generation von Slim-Floor Trägern<br />
CoSFB (= Composite SFB)<br />
C<strong>et</strong>te poutrelle allie de façon<br />
innovante les avantages du<br />
système slim-floor avec ceux<br />
de la construction mixte; à<br />
savoir robustesse, longévité,<br />
résistance ductile, gr<strong>and</strong>e portée<br />
<strong>et</strong> tenue à l’incendie intégrée.<br />
En construction mixte classique,<br />
la dalle de béton est connectée<br />
à la poutrelle en acier via des<br />
goujons soudée sur la semelle<br />
supérieure. Dans le cas du CoSFB,<br />
la connexion s’effectue par<br />
des aciers d’armatures passant<br />
à travers le profilé par des<br />
ouvertures situées dans la partie<br />
supérieure de l’âme. La rigidité<br />
ainsi obtenue est rendue maximale<br />
sans avoir à augmenter la hauteur<br />
du plancher. Ce système autorise<br />
d’atteindre des portées de 14<br />
mètres avec un espacement entre<br />
solives de 10 mètres pour une<br />
épaisseur totale de plancher de<br />
40 cm seulement! Et ceci avec<br />
une trés faible consommation<br />
moyenne d’acier de 25 kg/m 2 , une<br />
excellente tenue au feu intégrée<br />
(jusqu’à R90) <strong>et</strong> une diminution<br />
de jusqu'à 40 % de l'empreinte<br />
carbone.<br />
CoSFB (= Composite SFB)<br />
CoSFB combines the advantages<br />
of slim-floor <strong>and</strong> composite<br />
construction (robustness,<br />
durability, ductile behavior, large<br />
spans, integrated fire resistance).<br />
A CoSFB is designed by replacing<br />
the traditional shear studs with<br />
reinforcement bars, placed<br />
through drilled holes in the<br />
web of the hot rolled section.<br />
Thanks to this innovative <strong>and</strong><br />
efficient connection the stiffness<br />
of the complex is significantly<br />
increased without modifying the<br />
construction thickness (slab +<br />
beam).<br />
For a beam distance of 10m <strong>and</strong><br />
a slab thickness of 40cm, beam<br />
spans up to 14m can are possible!<br />
The steel consumption of CoSFB<br />
is typically around +/- 25kg/<br />
m 2 , including a integrated fire<br />
resistance (up to R90) <strong>and</strong> up to<br />
40% reduced carbon footprint.<br />
CoSFB (= Composite SFB)<br />
Dieser Träger kombiniert auf<br />
innovative Weise die Vorteile<br />
der Slim-Floor Bauweise<br />
mit denen des Verbundbaus<br />
(Robustheit, Dauer-haftigkeit,<br />
duktiles Tragverhalten, große<br />
Spannweiten, integrierter<br />
Feuerwiderst<strong>and</strong>). Im klassischen<br />
Verbundbau wird die Verbindung<br />
zwischen Stahlprofil und Ortb<strong>et</strong>on<br />
durch auf den Obergurt aufgeschweißte<br />
Kopfbolzendübel<br />
erzielt. Beim CoSFB jedoch wird<br />
die Verbundtragwirkung über<br />
durch den Trägersteg geführte<br />
Bewehrungsstäbe sichergestellt.<br />
So wird die Steifigkeit maximiert,<br />
ohne die Konstruktionshöhe zu<br />
vergrößern. Mit dieser Bauweise<br />
können Spannweiten bis zu 14m<br />
mit einem Trägerabst<strong>and</strong> von<br />
10m und einer Deckenstärke von<br />
lediglich 40cm realisiert werden!<br />
Dies bei einem durchschnittlichen<br />
Stahlverbrauch von lediglich<br />
25kg/m 2 und integriertem<br />
Br<strong>and</strong>schutz (bis zu R90) und bis<br />
zu 40% weniger CO 2-Verbrauch.<br />
25