IMPORTANT DIRECTIONS<br />

Before starting the assembly of the solar heater, take into account the following directions :<br />

- The solar heater should be placed in a way that its collector see the south (in the northern hemisphere) or see the north (in the southern hemisphere),<br />

- The place, that you will place the solar heater, must not be shaded and should be as near as possible to consumption,<br />

- During works, the collectors should be covered from the sun to prevent any damage on the closed loop of the system,<br />

- During the set-up, first fill the tank with the domestic cold water before filling the solar circuit with the antifreeze/water mixture (at least 15% antifreeze),<br />

- The anti-freezing and anti-corrosive liquid delivered should be added to the closed loop after it has been diluted with water. Concentration must fit to the place,<br />

- As temperature of over 60°C occur in the system a suitable domestic hot water mixing valve must be used on the domestic hot water side to avoid scalding.<br />

SPECIFICATIONS:<br />

The thermosyphon system <strong>com</strong>prises the following <strong>com</strong>ponents: solar tank, collector(s), frame and installation kit (a detailed listing may be found below)<br />

The maximum operating pressure on the domestic hot water side is 6 bars. A pressure reducer is re<strong>com</strong>mended in the event that the domestic hot water pressure<br />

is higher. The maximum pressure in the closed solar circuit is 1,5 bars. The solar tank is enamelled on the inside and equipped with two sacrificial magnesium<br />

anodes to inhibit corrosion. 1,2 propylene glycol is used to provide frost and corrosion protection in the solar circuit.<br />

PACKAGING AND TRANSPORT:<br />

The system is packed in such a way as to prevent damages as far as possible. The products must be stored away from effects of the weather.<br />

The packaging must be removed if the products are temporarily stored outdoors.<br />

INSTALLATION GUIDELINES:<br />

Before installing the system, ensure that the mounting surface (roof surface) will withstand the weight of the thermosyphon system when filled. Written confirmation<br />

must be obtained from the architect/designer. The system must be installed at least 1m from walls or at the end of the roof to assist with maintenance of the system.<br />

The piping must be sealed with a suitable roof insertion to prevent moisture getting in the roof. Precise guideline must also be provided by the architect for this.<br />

All connection pipes must be very well insulated and UV resistant. The correct insulating material and insulation thickness must be selected according to local<br />

conditions.<br />

FRAMES:<br />

The roof construction must be capable of withstanding the appropriate wind and snow loads. (1m³ powder snow = 60kg, 1m³ wet snow = 300kg).<br />

The local conditions for snow and wind loads must be taken into consideration when mounting the system. Please consult local dealers for further information.<br />

SAFETY EQUIPMENT:<br />

A pressure relief valve with an opening pressure of 1,5 bars is used in the solar circuit. This valve is mounted on the tank in a ½ inch sleeve. The pressure relief<br />

valve for domestic hot water is also installed in ½ inch sleeve above the tank.The solar pressure relief valve can also be fed through the overflow hose into a<br />

container to trap the glycol.<br />

WARNING: the collector should be covered before and during filling.<br />

GB<br />