You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Plast</strong> <strong>Coat</strong> <strong>25</strong> · <strong>35</strong>GBControl unit4.1 Control unit1 Master switch 0–12 Indicator lamp3 Feed rate regulator 0–104 Changeover switch5 Mains cable6 Connection for remote control64.1.1 Symbols on the changeover switch(fig. 4)1 Releasing the pressure or removing the pump jacket.Pump runs in reverse direction.2 “0” drive is switched off.3 “AUTO” remote control using the spray lance.4 Spraying or pulling on the pump jacket.Pump runs in the forwards direction.2 3OAUTO.21 431The mortar spraying machine can be switched on using themaster switch (1, fig. 3).The indicator lamp (2) shows that the machine is ready for operation.The feed rate can be continuously adjusted by means of thefeed rate switch (3).544.2 DriveIf overloading occurs then the mortar spraying machineswitches off. Turn master switch (1, fig. 3) and changeoverswitch (4, fig. 3) to “0”. Wait at least 10 seconds and then turnthe mortar spraying machine back on.4.3 Receptacle (fig. 5)1 receptacle made of high-grade steel with grating.Contents: 60 liter131