3. Installation of <strong>MCS</strong> <strong>50</strong> and Microphone Units<br />

3.1 Single Cable Connection<br />

3.2 Branch Cabling<br />

1. Before connecting the <strong>MCS</strong> <strong>50</strong> to the mains, please check<br />

the supply voltage (refer to chapter 4. “Supply Voltage”).<br />

2. Address the microphone units as described in the chapter<br />

1.3 “Addressing the microphone units”.<br />

3. Connect the first microphone unit to the line input of the<br />

<strong>MCS</strong> <strong>50</strong> discussion control unit. The other microphone<br />

units are connected according to the single cable principle,<br />

i.e. the second microphone unit is connected to the first<br />

one, the third to the second one etc.<br />

4. It is possible to connect up to 32 microphone units in one<br />

line to the <strong>MCS</strong> <strong>50</strong>/32 and up to 64 microphone units in<br />

two lines to the <strong>MCS</strong> <strong>50</strong>/64.<br />

1. Before connecting the <strong>MCS</strong> <strong>50</strong> to the mains, please check<br />

the supply voltage (refer to chapter 4. “Supply Voltage”).<br />

2. Address the microphone units as described in the chapter<br />

1.3 “Addressing the microphone units”.<br />

3. Connect a 15-pin Sub-D cable to the line input of the<br />

<strong>MCS</strong> <strong>50</strong> discussion control unit. Connect a CA 1513<br />

triple distributor to the other end of the cable. Connect<br />

two microphone units to the CA 1513 triple distributor.<br />

The last triple distributor in the line allows to connect<br />

3 microphone units.<br />

4. It is possible to connect up to 32 microphone units in one<br />

line to the <strong>MCS</strong> <strong>50</strong>/32 and up to 64 microphone units in<br />

two lines to the <strong>MCS</strong> <strong>50</strong>/64.<br />

Note:<br />

The total length of the bus cable must not exceed 300 m. Each branch cable in this installation must not exceed 5 m.<br />

Safety instructions<br />

Make sure that the <strong>MCS</strong> <strong>50</strong> discussion control unit is always switched off when connecting, disconnecting or addressing the microphone<br />

units.<br />

4. Supply Voltage / Power Supply<br />

The power supply unit has been developed for an input voltage of 85 V to 264 V AC (<strong>50</strong>/60 Hz).<br />

Caution:<br />

If the F101 fuse of the integrated power supply (refer also to No. 200 in “Exploded View and Spare Parts, <strong>MCS</strong> <strong>50</strong> Discussion Control Unit”, page 48<br />

to 49) is defective, you should replace the whole part. A different fuse with a higher value than 6.3 A can destroy the power supply.<br />

Please contact your beyerdynamic-dealer.<br />