ENGLISH<br />
oven (see the picture)<br />
4- Reassemble the back of the oven<br />
b- it is necessary to connect the oven’s chimney to<br />
the appropriate entry placed on the back side of<br />
the hood by using the silicone tube supplied with<br />
the hood. The silicone tube has to be tightened<br />
to the oven’s chimney by using the metallic clamp<br />
(supplied also with the hood).<br />
In case the hood is connected to only one<br />
oven, the smoke entry that remains free must be<br />
connected to the condensate drainage system<br />
tube.<br />
CONNECTION SECOND OVEN<br />
In equipment with the hood there’s a second oven-<br />
UNO<br />
hood connection cable : such a cable allows to<br />
connect two ovens to same hood ( overlapped<br />
ovens). The hood is indifferently controlled by the<br />
first or the second oven. An extremity of the cable<br />
goes connected to the hood’s control card (connector<br />
HOOD/SC2 CN5) while the other extremity goes<br />
connected to second oven.<br />
The chimney of the second oven goes connected to<br />
the appropriate entry in the back side of the hood (the<br />
silicone tube in order to connect the second oven is<br />
supplied in equipment with the overlap’s kit XC610).<br />
4.3 WATER CONNECTION<br />
CONNECTION TO THE WATER SYSTEM<br />
It is necessary to place between the water system and<br />
the hood an interception plug cock and a mechanical<br />
filter. Before connecting the water pipe to the hood,<br />
please let a certain quantity of water flow to clean any<br />
eventual remainder. The incoming water should have<br />
a nominal pressure value included between 0.5 and<br />
2 bars.<br />
CONNECTION OF THE CONDENSATE<br />
DRAINAGE SYSTEM<br />
The condensate drainage system is located on the<br />
back side of the hood and goes connected with a<br />
rigid or flexible tube and piped to an open drainage;<br />
its diameter shouldn’t be inferior to the one of the<br />
drainage attack. Lock the tube by using the metallic<br />
clamp so that the same tube does not extract from the<br />
drainage.<br />
Don’t throttle the flexible conduits & avoid elbows<br />