ENGLISH<br />

oven (see the picture)<br />

4- Reassemble the back of the oven<br />

b- it is necessary to connect the oven’s chimney to<br />

the appropriate entry placed on the back side of<br />

the hood by using the silicone tube supplied with<br />

the hood. The silicone tube has to be tightened<br />

to the oven’s chimney by using the metallic clamp<br />

(supplied also with the hood).<br />

In case the hood is connected to only one<br />

oven, the smoke entry that remains free must be<br />

connected to the condensate drainage system<br />

tube.<br />

CONNECTION SECOND OVEN<br />

In equipment with the hood there’s a second oven-<br />

UNO<br />

hood connection cable : such a cable allows to<br />

connect two ovens to same hood ( overlapped<br />

ovens). The hood is indifferently controlled by the<br />

first or the second oven. An extremity of the cable<br />

goes connected to the hood’s control card (connector<br />

HOOD/SC2 CN5) while the other extremity goes<br />

connected to second oven.<br />

The chimney of the second oven goes connected to<br />

the appropriate entry in the back side of the hood (the<br />

silicone tube in order to connect the second oven is<br />

supplied in equipment with the overlap’s kit XC610).<br />

4.3 WATER CONNECTION<br />

CONNECTION TO THE WATER SYSTEM<br />

It is necessary to place between the water system and<br />

the hood an interception plug cock and a mechanical<br />

filter. Before connecting the water pipe to the hood,<br />

please let a certain quantity of water flow to clean any<br />

eventual remainder. The incoming water should have<br />

a nominal pressure value included between 0.5 and<br />

2 bars.<br />

CONNECTION OF THE CONDENSATE<br />

DRAINAGE SYSTEM<br />

The condensate drainage system is located on the<br />

back side of the hood and goes connected with a<br />

rigid or flexible tube and piped to an open drainage;<br />

its diameter shouldn’t be inferior to the one of the<br />

drainage attack. Lock the tube by using the metallic<br />

clamp so that the same tube does not extract from the<br />

drainage.<br />

Don’t throttle the flexible conduits & avoid elbows<br />