Connecting the oil return line<br />

B<br />

A<br />

1. Connect the return line to the top of the cylinder of secondary column B.<br />

2. Route the oil return line on the secondary column upwards, over the crossbar to the cylinder of main column<br />

A.<br />

3. Connect the return line to the T-piece on the top of the cylinder of main column A.<br />

4. Route the return line from the T-piece to the connection on the unit.<br />

5. Check that the connections are properly seated to avoid leaks.<br />

6. Check that the hose is laid correctly to avoid damage.<br />

2.9.7 Installing electrical connections<br />

Connecting the control valves<br />

B<br />

A<br />

1. Connect the electric cable from the power pack to the solenoid valve on the top of the main column A<br />

cylinder.<br />

® Copyright <strong>ATH</strong>-<strong>Heinl</strong> GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved<br />

Release date: 26.01.2024 / Product manufacturer <strong>ATH</strong>-<strong>Heinl</strong> GmbH & Co. KG<br />