1. Go to the start screen and select “Settings”. Enter the password for the calibration.<br />

2. Select “Calibration” and the above screen appears.<br />

3. Remove any load from the <strong>lift</strong> before starting the calibration.<br />

4. Select a reference point on the <strong>lift</strong> truck.<br />

5. Lower the <strong>lift</strong> completely and measure the distance from the floor to your reference point.<br />

6. Enter the respective value of the main or secondary column at H0I or H1I.<br />

7. Raise the <strong>lift</strong> to the maximum <strong>lift</strong>ing height and measure the distance from the ground to your reference<br />

point.<br />

8. Enter the respective value of the main or secondary column at H0h or H1h.<br />

9. Press “Exit” to save the entered values and end the calibration.<br />

ü<br />

The altitude values displayed should now correspond exactly to the values you measured at the reference<br />

point.<br />