S exAMPLeS the breakdown of the Ballerup Bicycle<br />
Arena and the Valby Arena can be mentioned as<br />
well as several farm buildings that could not withstand<br />
snow loads that did not exceed the load specifications in<br />
the standards.<br />
We have also during the past years seen several breakdowns<br />
in scaffoldings for concrete bridges, unfortunately<br />
resulting in the loss of life. It is therefore essential<br />
that the building regulation together with the eurocodes<br />
0, require independent control of structures in the high<br />
consequence class and that third part control is carried<br />
out at the extreme high consequence class. This control<br />
is to be carried out by an independent company not<br />
involved in the design.<br />
equivalent, independent control of the contractors’ scaffolding<br />
structures is required by BaneDanmark as well<br />
as by the Danish Road Authorities – The Vejdirektoratet.<br />
The main task is here to check load capacity and stability<br />
of temporary scaffoldings as it is defined in “The<br />
Handbook for inspection of bridge contracts”.<br />
The certified statical controllers at <strong>ISC</strong> have for such<br />
cases been assigned the task of monitoring that the<br />
statical documentations is sufficient, adequate and correct.<br />
One of the main principles in the independent control<br />
is that the design is looked upon with new eyes and<br />
everything vital for the functionality and use of the load<br />
bearing structures is thoroughly reviewed. The purpose<br />
of the control is to verify that the chosen solutions are<br />
relevant for the functionality, secure and fulfills the<br />
requirements for stability and without any flaws or lacks<br />
in the statical documentation can be found. The documentation<br />
is terminated with an approval report as well<br />
as a memorandum as appendix to the overall statical<br />
documentation for the particular assignment.<br />
Having a large number of highly skilled and experienced<br />
design engineers and statics employed it has been<br />
obvious for <strong>ISC</strong> to take an active part in this particular<br />
area. During the past years <strong>ISC</strong> has carried out static<br />
control of large concrete buildings, bridges and scaffoldings.<br />
The new university hospital at Aarhus, the<br />
Teglvaerks Bridge, antenna masts, high storage buildings<br />
and stadiums can be mentioned as examples.<br />
This extra control has come to stay. The strong need<br />
is further emphasized by the fact that the education<br />
at the technical universities in elementary statical and<br />
physical understanding of structures and their function<br />
has gradually been degraded in line with the increasing<br />
implementation of readymade statical design programs.<br />
Tests recently given to young engineers in this topic at<br />
DTU and in the larger Danish engineering companies<br />
have shown alarmingly bad results. We recommend that<br />
the educational institutions upgrade this area instantly.<br />
At <strong>ISC</strong> we ensure that our engineers when employed<br />
are given a general brush up on the topic so that all<br />
our structural engineers have a general understanding<br />
of statics and are able to solve any task in an accurate<br />
manner.<br />