SOFT DRIVE<br />

Description / Control<br />

Fig.1<br />

When the SOFT DRIVE is engaged and the shut-off<br />

valve open, the gas in accumulator A will be compressed.<br />

The accumulators can now be checked by<br />

measuring the movement of the rams under different<br />

strains (static) at two different pressures.<br />

Since the temperature of the oil and the diameter of the<br />

rams affect this movement, below table will serve as<br />

guidance.<br />

Accumulator B will slow down the movement of the<br />

beam in the opposite direction (UPWARDS).<br />

CHECK OF ACCUMULATOR (A)<br />

1) Connect a manometer to the hose from the loader lift<br />

rams (the +side) (BLUE hose) with the shut-off valve<br />

in OPEN position.<br />

2) Oil temperature - about 20° C.<br />

3) The bucket shall be loaded in such a way that a<br />

pressure of 100 bar is achieved.<br />

4) Measure the distance between the cylinder bearing<br />

and the piston rod bearing (X).<br />

5) Reduce (empty) the load to achieve a pressure level<br />

of 50 bar.<br />

6) Measure the distance between the cylinder bearing<br />

and the piston rod bearing (X). NOTE ! do NOT lift /<br />

lower beam between measurements.<br />

7) The movement (min.) of the piston rod shall comply<br />

with the values specified in below table (A).<br />

ENGLISH (117-501)<br />

CONTROL OF ACCUMULATOR B<br />

1) Connect a manometer to the hose from the loader lift<br />

rams (the -side) (GREEN hose).<br />

2) Push the front part of the implement towards the<br />

ground with the bucket ram until a pressure of 100<br />

and 50 bar respectively has been achieved.<br />

3) Measure the movement of the piston rod and compare<br />

with the values below (B).<br />

NOTE !<br />

The warranty period for the accumulators is limited to<br />

twelve (12) months. Depending on the extent of use, the<br />

gas will diffuse in course of time. In such cases the<br />

accumulator must be exchanged.<br />

1<br />

The following values apply at an oil temperature of 20°C<br />

CYL. Diam.<br />

Movement of piston rod ( 100 - 50 bar)<br />

Ackumulator (A) Ackumulator (B)<br />

65/40 mm 10 - 11 mm 18 - 19 mm<br />

70/40 mm 9 - 10 mm 14 - 15 mm<br />

75/40 mm 8 - 9 mm 11 - 12 mm<br />

80/40 mm 15 - 16 mm 10 - 11 mm<br />

90/40 mm 12 - 13 mm 7 - 8 mm<br />

90/50 mm 12 - 13 mm 8 - 9 mm<br />