SOFT DRIVE<br />
Description / Control<br />
Fig.1<br />
When the SOFT DRIVE is engaged and the shut-off<br />
valve open, the gas in accumulator A will be compressed.<br />
The accumulators can now be checked by<br />
measuring the movement of the rams under different<br />
strains (static) at two different pressures.<br />
Since the temperature of the oil and the diameter of the<br />
rams affect this movement, below table will serve as<br />
guidance.<br />
Accumulator B will slow down the movement of the<br />
beam in the opposite direction (UPWARDS).<br />
CHECK OF ACCUMULATOR (A)<br />
1) Connect a manometer to the hose from the loader lift<br />
rams (the +side) (BLUE hose) with the shut-off valve<br />
in OPEN position.<br />
2) Oil temperature - about 20° C.<br />
3) The bucket shall be loaded in such a way that a<br />
pressure of 100 bar is achieved.<br />
4) Measure the distance between the cylinder bearing<br />
and the piston rod bearing (X).<br />
5) Reduce (empty) the load to achieve a pressure level<br />
of 50 bar.<br />
6) Measure the distance between the cylinder bearing<br />
and the piston rod bearing (X). NOTE ! do NOT lift /<br />
lower beam between measurements.<br />
7) The movement (min.) of the piston rod shall comply<br />
with the values specified in below table (A).<br />
ENGLISH (117-501)<br />
CONTROL OF ACCUMULATOR B<br />
1) Connect a manometer to the hose from the loader lift<br />
rams (the -side) (GREEN hose).<br />
2) Push the front part of the implement towards the<br />
ground with the bucket ram until a pressure of 100<br />
and 50 bar respectively has been achieved.<br />
3) Measure the movement of the piston rod and compare<br />
with the values below (B).<br />
NOTE !<br />
The warranty period for the accumulators is limited to<br />
twelve (12) months. Depending on the extent of use, the<br />
gas will diffuse in course of time. In such cases the<br />
accumulator must be exchanged.<br />
1<br />
The following values apply at an oil temperature of 20°C<br />
CYL. Diam.<br />
Movement of piston rod ( 100 - 50 bar)<br />
Ackumulator (A) Ackumulator (B)<br />
65/40 mm 10 - 11 mm 18 - 19 mm<br />
70/40 mm 9 - 10 mm 14 - 15 mm<br />
75/40 mm 8 - 9 mm 11 - 12 mm<br />
80/40 mm 15 - 16 mm 10 - 11 mm<br />
90/40 mm 12 - 13 mm 7 - 8 mm<br />
90/50 mm 12 - 13 mm 8 - 9 mm<br />