Roller shutter control<br />
Alarm object<br />
Menu Settings<br />
Use alarm object No · Yes<br />
If „Yes“: If alarm object value = 1<br />
If alarm object value = 0<br />
no action · stop · up-comm<strong>and</strong> · down-comm<strong>and</strong><br />
◆ In case of manual <strong>operation</strong>s be<strong>for</strong>e <strong>and</strong> after alarm no action · move to last position<br />
◆ In case of automatic <strong>operation</strong> after alarm Follow automatic<br />
Value of the object be<strong>for</strong>e 1st communication <strong>and</strong> restoration of bus voltage 0 · 1<br />
Blocking object 1 / 2<br />
Menu Settings<br />
Use blocking object 1 No · Yes<br />
If „Yes“: If blocking object value = 1 no action · stop · up-comm<strong>and</strong> · down-comm<strong>and</strong><br />
If blocking object 1 value = 0<br />
◆ In case of manual <strong>operation</strong>s be<strong>for</strong>e <strong>and</strong> after blocking no action · move to last position<br />
◆ In case of automatic <strong>operation</strong> after blocking Follow automatic<br />
Value of the object be<strong>for</strong>e 1st communication <strong>and</strong> restoration of bus voltage 0 · 1<br />
Use blocking object 2 No · Yes<br />
If „Yes“: Use settings “blocking object 1” see „Blocking object 1“<br />
Wind block<br />
Menu Settings<br />
Use wind block<br />
NOTE<br />
When blocking, the roller shutter moves up.<br />
No · Yes<br />
If „Yes“: Type of input object 1 Bit · 16 Bit<br />
If „1 Bit“: Waiting time in safe position in min. after wind block 0 … 255<br />
Behaviour after waiting period:<br />
◆ In case of manual <strong>operation</strong> be<strong>for</strong>e <strong>and</strong> after wind alarm no action · move to last position<br />
◆ In case of automatic <strong>operation</strong> after blocking Follow automatic<br />
If „16 Bit“: From wind speed in m/sec up-comm<strong>and</strong> 2 … (5) … 30<br />
Waiting time in safe position in min. after wind alarm 0 … 255<br />
Behaviour after waiting period:<br />
◆ In case of manual <strong>operation</strong> be<strong>for</strong>e <strong>and</strong> after wind alarm no action · move to last position<br />
◆ In case of automatic <strong>operation</strong> after blocking Follow automatic<br />
Send current blocking status No · Yes<br />
<strong>EN</strong><br />
69