21.04.2015 Aufrufe

o_19jdnovcg1eh21852116govv1lgra.pdf

Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.

YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.

WIND LOADS<br />

Wind loads for temporary structures<br />

... to continue<br />

Permeable wall covers<br />

For wall roofs so called gauzes<br />

are used very often. This<br />

is a translucent textile.<br />

side cover with gauze<br />

Often the apparent permeability<br />

of this textile is pointed<br />

out and sometimes the corresponding<br />

wind loads are reduced.<br />

Wind tunnel tests<br />

showed that a reduction of<br />

the wind loads is only permissible<br />

for very coarsely meshed<br />

(5 x 5 cm) textiles. For<br />

the typical gauzes that are<br />

used nowadays a reduction<br />

of the wind load is not permissible.<br />

The often indicated<br />

value of air permeability<br />

does not mean necessarily<br />

that the gauze is wind permeable.<br />

A wind permeability<br />

may only be taken into account<br />

if a cf-value that has<br />

been tested in a wind tunnel<br />

for that type of gauze is<br />

given by the manufacturer.<br />

Autors:<br />

Frank Bastians, Stefan Krasenbrink, Jan Keppler, Ralf-Harald vom Felde.<br />

Further information of the autors under:<br />

www.krasenbrink-bastians.de sowie www.vom-felde.de<br />