SERVICE MANUAL SERIES 320 XR - Precisa
SERVICE MANUAL SERIES 320 XR - Precisa
SERVICE MANUAL SERIES 320 XR - Precisa
- Keine Tags gefunden...
Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.
YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.
Series <strong>320</strong> <strong>XR</strong>Error messages2.3 Hardware error(Balance stays still)ERROR-No. ERROR responsibility ERROR repairERROR 14 wrong model code call serviceERROR 16 internal RAM destroyed replace CPUERROR 17 external RAM destroyed replace RAMERROR 18 / 1 wrong program check sum load right program, replace FLASHERROR 18 / 2 no approved program build in approved balance load right programERROR 18 / 8 FLASH empty load right program, replace FLASHERROR 18 / 9 wrong controller check sum replace CPUERROR 19 wrong code figure load right code figureERROR 20 / 1 temperature measurement Zelle defective call serviceERROR 20 / 2 temperature measurement magnet defective call serviceERROR 20 / 4 ADC-reference-sensor defective call serviceERROR 28 no temperature values in °C call service<strong>Precisa</strong> Gravimetrics AG Index b2 F9