Operation Manual <strong>GSM</strong>-2 (GPRS Standard Mode)<br />
• Commands of the EFOY Pro fuel cell system<br />
You can monitor the operating status, modify the operating parameters and establish external control<br />
via the EFOY Pro terminal data interface. Communication is via an RS232 standard serial interface<br />
with the following parameters:<br />
• 9600 bit/s<br />
• 8 bits/Byte<br />
• 1 stop bit<br />
• no parity<br />
• no flow control<br />
You can verify whether a successful connection has been established by sending a „Return“ sign<br />
(ASCII Code 13) to the fuel cell. If the connection has been established, the device will respond with<br />
the following prompt:<br />
- SFC>↵<br />
- SFC><br />
Thirteen commands are available. In the examples below, signs sent to the device are shaded in grey,<br />
all other signs have been generated by the EFOY Pro device.<br />
? [ ]<br />
This command (just the question mark) delivers the instruction set of the device with a brief<br />
description.<br />
Example:<br />
SFC>?↵<br />
Set of commands<br />
? shows the set of commands<br />
BUTTON software controlling of device<br />
CONFIG setting customized operation parameters<br />
DEFAULT setting default operation parameters<br />
LANGUAGE setting language for panel<br />
LIMITS reading out limits of operation parameters<br />
LOCKED locking control contacts<br />
REMOTE remote controlling via software interface<br />
RESET restarts the device<br />
SFC reading out actual operation state<br />
STDVALUE reading out default values for operation<br />
parameters<br />
VALUE reading out actual set of operation<br />
parameters<br />
VER reading out version of firmware...<br />
...<br />
SFC>