7.5 Length of the refilling tubes<br />

Keep the refilling tubes as short as possible. Caused by the thermal expansion<br />

of air, any air inside the tubes will affect the readings when temperature<br />

changes. Preferably, insulate the refilling tubes or install them isothermal into<br />

the soil.<br />

7.6 Jacket tubes<br />

Jacket tubes are useful with shafts longer than 2 m, in pebbly soils or gravel,<br />

and for horizontal installations from inside a well or pit hole. The jacket tube<br />

should end 30 to 50 cm away from the cup so leaking or condensation water is<br />

not conducted to the cup. The inner diameter of the jacket tube should be at<br />

least 35 mm.<br />

7.7 Ideal condition for installation<br />

For the installation of Tensiometers, the ideal conditions are:<br />

- Frost-free soil.<br />

- Coarse clay or loess.<br />

- In soil types loess, coarse clay, loam or clay as well as in highly organic soils<br />

(humus) preferably with a water tension close to saturation (moist).<br />

- In sandy or pebbly soils with a water tension over 100 hPa (rather dry).<br />

- Low skeletal structure (gravel). The more gravel in a soil the more often<br />

the drilling has to be repeated to reach the required depth.<br />