8.2 Connecting the IR-indicator<br />

Some datalogger types require a pull-down resistor (for example 10 kOhm)<br />

against ground for the IR-indicator. Other logger types already have an internal<br />

pull-down resistor, or a pull-up resistor to 5 V, for example for connecting a<br />

reed switch. The external pull-down resistor must be smaller than the logger<br />

internal pull-up resistor or at least be in a relation so the logger will recognize<br />

the zero level.<br />

8.3 Wire specifications<br />

26<br />

white = V in Power supply plus, 6 … 20 V DC<br />

brown = GND Power supply minus<br />

green = Signal + Soil water tension plus<br />

red = Signal Temp Temperature plus<br />

yellow = Signal - Minus for soil water tension and temperature<br />

grey = Signal IR IR-indicator, switched with Vin pink = Calibration SDA (digital)<br />

blue = Calibration SCL (digital)