Description of Calculations<br />

1. Precedence rule -<br />

Eng i neer i ng<br />

Variables<br />

TOT CAP<br />

TSATUR<br />

TSTURB<br />

KAV<br />

Description<br />

The total design (rated) capacity<br />

of each equ i pme nt type<br />

(summed over all sizes of a<br />

given type).<br />

The steam saturation temperature.<br />

The temperature of steam entering<br />

the steam-turbine generator.<br />

The number of units of each<br />

equipment type.<br />

The first variables calculated in this routine are those associated with<br />

the "precedence rule" discussed under the PLANT-EQUIPMENT cOlTf11and in the<br />

<strong>DOE</strong>-2 Reference <strong>Manual</strong> (Ref. 2). Briefly, this rule states that, unless<br />

the user allocates equipment loads through the use of the LOAD-ASSIGNMENT<br />

and the LOAD-MANAGEMENT commands, only one type of boiler, compression<br />

chiller, absorption chiller, and cooling tower will be allowed to operate.<br />

This rule does not apply to different sizes of the same equipment type.<br />

For example, two different sizes of fossil fuel steam boilers can be input<br />

without making use of a LOAD-ASSIGNMENT and the program will operate them<br />

by default with no difficulty. However, if an electric steam boiler is<br />

input in addition to a fossil fuel steam boiler, only the fossil fuel<br />

steam boiler' will operate. The reason is that the default allocation<br />

algorithms are not general enough to allow more than one type in each<br />

equipment category. This is not a serious problem, because it is not<br />

very likely that an electric steam boiler would be used in the same plant<br />

as a fossil fuel steam boiler. However, if such a combination is to be<br />

used, the user must input a LOAD-ASSIGNMENT to instruct the program how<br />

they are to be used.<br />

2. Steam data -<br />

The steam pressure, temperature, enthalpy and entropy are used in the<br />

steam turbine algorithm. The steam saturation temperature is used in the<br />

diesel engine and gas turbine generator routines to calculate the heat<br />

recoverable from the exhaust gases.<br />