Coax High Voltage<br />
Dimensions<br />
Cable Mounted Plugs<br />
■ S/SE and SV/SVE Body Styles<br />
Type A B D D1 dmax<br />
1<br />
Unsealed Sealed<br />
102 A 018<br />
Z<br />
102 A 025<br />
Z<br />
103 A 023<br />
Z<br />
104 A 010<br />
Z<br />
105 A 004<br />
Z<br />
105 A 005<br />
Z<br />
1) Cable screen and jacket (e.g. RG-58) are retained by hex-crimp to the plug shell.<br />
2) For improved safety, the center contact is further recessed than in the S 105 A049.<br />
3) Two wrenches with an opening of 32 mm are required for SV/SVE 107 series.<br />
4) For insertion of center contact which has to be assembled after wiring, we recommend tool<br />
TP00.000, as shown on page 12-3.<br />
Torque 1<br />
[Nm]<br />
36 26 9 11 4.7 4.3 7 0.6 7<br />
60 46 9 -<br />
Crimping tool and dies 1)<br />
TX00.241 & TX00.251<br />
46 35 12 13 6.7 6.2 10 1.0 10<br />
50 38 15 20 8.7 8.7 12 2.0 13<br />
62 47 18 22 10.7 10.7 15 3.5 16<br />
62 47 18 22 10.7 10.7 15 3.5 16<br />
105 A 049<br />
Z 4) 90 60 18 22 15 3.5 16<br />
105 A 108 2)<br />
10.7 10.7<br />
100 60 18 - 10.7 - 15 3.5 16<br />
107 A 003<br />
Z<br />
110 85 34 38 22.7 - 32 10 32<br />
107 A 004 137 112 34 38 22.7 - 30 10 32<br />
107 A 017<br />
Z<br />
ød<br />
ød<br />
137 112 34 38 30 3)<br />
22.7 22.7<br />
Suitable Coax cables are indicated in the column "Cable Group" in Electrical & Contact specifications. The cable specifications are listed on<br />
page 6-9. If required, we will supply adapter sleeves which must be placed over the cable dielectric during assembly in order to guarantee<br />
proper performance.<br />
For cable clamps sets see page 4-11. For non-sealed Coax connectors, the collet diameter has to be selected from the tables of<br />
type "S-Shielded", and for sealed Coax connectors from the tables of type "Environmental".<br />
All dimensions shown are in millimeters and are for reference only.<br />
Torque [Nm] are recommended values that may be influenced by the characteristics of the cable jacket.<br />
Tests have to be made to evaluate the exact values. To secure the cable clamp nut, we recommend the use of thread locking adhesive.<br />
~B<br />
1 2<br />
1 2<br />
~B<br />
øD1<br />
5.2<br />
~A<br />
~A<br />
-<br />
øD<br />
øD<br />
S/SE<br />
SV/SVE<br />
10 32<br />
2<br />