Coax High Voltage<br />

Dimensions<br />

Cable Mounted Plugs<br />

■ S/SE and SV/SVE Body Styles<br />

Type A B D D1 dmax<br />

1<br />

Unsealed Sealed<br />

102 A 018<br />

Z<br />

102 A 025<br />

Z<br />

103 A 023<br />

Z<br />

104 A 010<br />

Z<br />

105 A 004<br />

Z<br />

105 A 005<br />

Z<br />

1) Cable screen and jacket (e.g. RG-58) are retained by hex-crimp to the plug shell.<br />

2) For improved safety, the center contact is further recessed than in the S 105 A049.<br />

3) Two wrenches with an opening of 32 mm are required for SV/SVE 107 series.<br />

4) For insertion of center contact which has to be assembled after wiring, we recommend tool<br />

TP00.000, as shown on page 12-3.<br />

Torque 1<br />

[Nm]<br />

36 26 9 11 4.7 4.3 7 0.6 7<br />

60 46 9 -<br />

Crimping tool and dies 1)<br />

TX00.241 & TX00.251<br />

46 35 12 13 6.7 6.2 10 1.0 10<br />

50 38 15 20 8.7 8.7 12 2.0 13<br />

62 47 18 22 10.7 10.7 15 3.5 16<br />

62 47 18 22 10.7 10.7 15 3.5 16<br />

105 A 049<br />

Z 4) 90 60 18 22 15 3.5 16<br />

105 A 108 2)<br />

10.7 10.7<br />

100 60 18 - 10.7 - 15 3.5 16<br />

107 A 003<br />

Z<br />

110 85 34 38 22.7 - 32 10 32<br />

107 A 004 137 112 34 38 22.7 - 30 10 32<br />

107 A 017<br />

Z<br />

ød<br />

ød<br />

137 112 34 38 30 3)<br />

22.7 22.7<br />

Suitable Coax cables are indicated in the column "Cable Group" in Electrical & Contact specifications. The cable specifications are listed on<br />

page 6-9. If required, we will supply adapter sleeves which must be placed over the cable dielectric during assembly in order to guarantee<br />

proper performance.<br />

For cable clamps sets see page 4-11. For non-sealed Coax connectors, the collet diameter has to be selected from the tables of<br />

type "S-Shielded", and for sealed Coax connectors from the tables of type "Environmental".<br />

All dimensions shown are in millimeters and are for reference only.<br />

Torque [Nm] are recommended values that may be influenced by the characteristics of the cable jacket.<br />

Tests have to be made to evaluate the exact values. To secure the cable clamp nut, we recommend the use of thread locking adhesive.<br />