13-7<br />

Determination of Operating Voltage<br />

General Recommendation for <strong>Connectors</strong> in Common Applications<br />

Technical Information<br />

Electrical Data<br />

IEC 60664: Generic standard recommended for typical electrical devices. It takes into account long term<br />

degradation of insulating materials under variable aggressive environmental influences and uses creepage<br />

distance as calculation basis for the operating voltage.<br />

<strong>Fischer</strong> <strong>Connectors</strong> recommends the use of IEC 60664 in the general multipole connector specifications,<br />

unless other more specific standard or regulations are applicable to the design. For example,<br />

IEC 60601 provides adequate special guidelines for medical devices.<br />

For cases where the connector “on-time” or duty cycle is low, and there is little exposure to environmental<br />

factors, for example scientific instruments or similar equipment, other previous standards such as former<br />

IEC 60130-1 can be used. It does not take into consideration either long term environmental effects,<br />

or the specific behaviour of different insulator materials and uses test voltage as calculation basis<br />

for the operating voltage<br />

Former IEC 60130-1 recommends to set the operating voltage at<br />

■ 0.33 x test voltage for 500V < test voltage < 3kV<br />

■ 0.66 x test voltage for test voltage ≥ 3kV<br />

Similar recommendations are provided in EIA-364-20 (MIL-STD-1344 method 3001 superseded).<br />