Multipole High Voltage<br />

Electrical & Contact Specifications<br />

A / Z Polarity<br />

For Multipole High Voltage connectors, it is essential to pay attention to the differences between type "A" and "Z".<br />

Type "A" Standard Polarity:<br />

The contacts of the receptacle are recessed to reduce the possibility of electric shock in the unmated position.<br />

This version should be used when the voltage is sourced from the receptacle.<br />

Type "Z" Inverted Polarity:<br />

The contacts of the plug are recessed to reduce the possibility of electric shock in the unmated position.<br />

This version should be used when the voltage is sourced from the plug.<br />

Protected contacts are usually female contacts recessed in the insulator. For Multipole High Voltage connectors,<br />

however, it is safer to recess the male contacts. In these cases, the plug type "A" is equipped with female contacts<br />

and the receptacle with protected male contacts.<br />

Example: Receptacles Type "A" Plug Type "A"<br />

D105 A039 S105 A039<br />

104, 105, 106 and 107 Series<br />

Type<br />

104 A 062<br />

Z<br />

Pin Layout<br />

Number of Contacts<br />

Contact<br />

Termination<br />

Solder<br />

Crimp<br />

Insulating Material<br />

Contact ø [mm]<br />

Wire Barrel ø [mm]<br />

Contact to Body<br />

Test Voltage [V]<br />

in mated position<br />

AC rms DC<br />

4 ● PEEK 0.9 0.8 4.5 4.5 7.5 7.5 8.0<br />

105 A 057 3 ● PTFE 1.3 1.2 4.5 6.0 8.0 10 14<br />

105 A 039<br />

Z<br />

106 A 013<br />

Z<br />

5 ● PTFE 1.3 1.2 4.5 4.5 7.0 7.0 11<br />

6 ● PTFE 1.3 1.2 8.0 8.0 12 12 12<br />

107 A 034 2) 3) 7 ● PTFE 2.0 2.0 8.0 7.5 14 14 20<br />

1) Recommended max. operating current per contact at 40°C temperature rise measured according to IEC 60512-3-5b.<br />

2) For clamp sets selection see page 4-11-8.<br />

3) See Section 12 Tooling, for insertion tool of contacts.<br />

Contact to Contact<br />

● = Standard ❍ = Option<br />

Contact to Body<br />

Contact to Contact<br />

Current Rating 1) [A]<br />

5-5