Download - Fischer Connectors
Download - Fischer Connectors
Download - Fischer Connectors
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Multipole High Voltage<br />
Electrical & Contact Specifications<br />
A / Z Polarity<br />
For Multipole High Voltage connectors, it is essential to pay attention to the differences between type "A" and "Z".<br />
Type "A" Standard Polarity:<br />
The contacts of the receptacle are recessed to reduce the possibility of electric shock in the unmated position.<br />
This version should be used when the voltage is sourced from the receptacle.<br />
Type "Z" Inverted Polarity:<br />
The contacts of the plug are recessed to reduce the possibility of electric shock in the unmated position.<br />
This version should be used when the voltage is sourced from the plug.<br />
Protected contacts are usually female contacts recessed in the insulator. For Multipole High Voltage connectors,<br />
however, it is safer to recess the male contacts. In these cases, the plug type "A" is equipped with female contacts<br />
and the receptacle with protected male contacts.<br />
Example: Receptacles Type "A" Plug Type "A"<br />
D105 A039 S105 A039<br />
104, 105, 106 and 107 Series<br />
Type<br />
104 A 062<br />
Z<br />
Pin Layout<br />
Number of Contacts<br />
Contact<br />
Termination<br />
Solder<br />
Crimp<br />
Insulating Material<br />
Contact ø [mm]<br />
Wire Barrel ø [mm]<br />
Contact to Body<br />
Test Voltage [V]<br />
in mated position<br />
AC rms DC<br />
4 ● PEEK 0.9 0.8 4.5 4.5 7.5 7.5 8.0<br />
105 A 057 3 ● PTFE 1.3 1.2 4.5 6.0 8.0 10 14<br />
105 A 039<br />
Z<br />
106 A 013<br />
Z<br />
5 ● PTFE 1.3 1.2 4.5 4.5 7.0 7.0 11<br />
6 ● PTFE 1.3 1.2 8.0 8.0 12 12 12<br />
107 A 034 2) 3) 7 ● PTFE 2.0 2.0 8.0 7.5 14 14 20<br />
1) Recommended max. operating current per contact at 40°C temperature rise measured according to IEC 60512-3-5b.<br />
2) For clamp sets selection see page 4-11-8.<br />
3) See Section 12 Tooling, for insertion tool of contacts.<br />
Contact to Contact<br />
● = Standard ❍ = Option<br />
Contact to Body<br />
Contact to Contact<br />
Current Rating 1) [A]<br />