C. Installation<br />

O 8<br />

O 9<br />

7.2.3 Setting OPEN travel limit<br />

• Move the door by hand to its mechanical OPEN travel limit.<br />

• Release the stop (grub screw J) of control cam (B).<br />

• Set control cam (B) in such way, that the OPEN limit switch (G) is<br />

actuated as shown in fig. 7.2.3 (position H).<br />

• Fix control cam (B) by screwing on grub screw (J).<br />

• Adjust door position OPEN, if necessary, by means of the fine<br />

adjustment screw (K) on the control cam.<br />

• Close the cover of housing again.<br />

Emergency Hand Chain (EHC):<br />

Picture shows installation of operator on left side!<br />

I = CLOSE II = OPEN<br />

Attention!<br />

Please take care, that, when connecting and<br />

mounting the emergency hand chain to the<br />

supplied piece of chain, the chain is not twisted.<br />

With a twisted chain malfunction will come up when operating the<br />

emergency hand chain.<br />

When operating the emergency hand chain, the operator will be<br />

separated from power supply!<br />

Quick release (QR):<br />

Picture shows installation of operator on left side!<br />

Attention!<br />

Observe local regulations regarding spring safety<br />

device or cable safety device.<br />